Search results for "ACL"
showing 10 items of 906 documents
Italian version of qualiveen-30: Cultural adaptation of a neurogenic urinary disorder-specific instrument
2011
Purpose Qualiveen-30 is a neurological urinary disorder (UD)-specific health-related quality of life (HRQL) instrument, recommended in the European Association of Urology guideline 2008. The objective is to complete the cultural adaptation of Qualiveen-30 into Italian. Materials and Methods One hundred and twenty eight Italian-speaking spinal cord injury (SCI) patients completed Qualiveen-30 and the SF-12 physical and mental component (PC and MC) at enrolment and 4 weeks later. At follow-up, patients also made global ratings of change (GRC) in urinary HRQL (GRC). Results Qualiveen-30 proved reliable (intraclass correlation coefficients of four domains: 0.77–0.90). Correlations with SF-12 an…
Quality Analysis of YouTube Videos Presenting Pelvic Floor Exercises after Prostatectomy Surgery
2021
Background: Prostate cancer (PC) is a major cause of disease and mortality among men. Surgical treatment involving the removal of the prostate may result in temporary or permanent erectile dysfunction (ED) and urinary incontinence (UI), with considerable impact on quality of life. Pelvic floor muscle training (PFMT) is one of the recommended techniques for the prevention, treatment, and rehabilitation of postoperative complications. The aim of this observational study was to assess the quality of YouTube videos—accessible to any patient—related to exercises after prostatectomy surgery. Methods: A systematic search was performed on YouTube on 24 September 2020. One hundred and fifty videos w…
THERapy–Related InterACTion (THER-I-ACT) in Rehabilitation—Instrument Development and Inter-Rater Reliability
2021
Objective: To develop an instrument for the observation of therapeutic communication interactions during rehabilitation sessions and test its inter-rater reliability.Methods: The new instrument THER-I-ACT (THERapy–related Inter-ACTion) has been designed to assess both the frequency and timing of therapeutic interactions in the thematic fields information provision, feedback, other motivational interaction, and bonding. For this inter-rater reliability study, a sample of stroke survivors received arm rehabilitation as either arm ability training, arm basis training, or mirror therapy, or neglect training as individually indicated. Therapy sessions were video-recorded (one for each participan…
Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®
2012
Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…
Construct validity and reliability of Finnish version of Örebro Musculoskeletal Pain Screening Questionnaire
2016
Abstract Introduction Chronic pain causes suffering for affected individuals and incurs costs to society through work disability. Interventions based on early screening of psychological risk factors for chronic pain using screening tools such as the Örebro Musculoskeletal Pain Screening Questionnaire (ÖMPSQ) have been found to reduce work absenteeism and health care visits and increase perceived health. The aim of the current study was to translate the ÖMPSQ into Finnish and test its validity and reliability in a patient sample. Methods The ÖMPSQ was forward–backward translated and cross-culturally adapted, and applied to our study population (n = 69), the members of which had been referred…
Reliability of iCare ic100 Rebound Tonometry and Agreement With Goldmann Applanation Tonometry in Healthy and Post-myopic LASIK Patients.
2021
Rebound tonometry offers excellent reliability for obtaining intraocular pressure (IOP) measurements in healthy and post-myopic laser-assisted in situ keratomileusis (LASIK) patients regardless of corneal parameters and axial length and regardless of the instillation of ocular topical anesthesia.The purpose of this study was to assess the reliability of rebound tonometry, its agreement with Goldmann applanation tonometry (GAT) and its concordance after topical anesthesia in a group of nonoperated healthy patients and a group of post-myopic LASIK patients.Fifty-four patients were included in this prospective observational, case-control study. Patients were divided into 2 groups: control (n=3…
Similar biomechanical properties of four tripled tendon graft models for ACL reconstruction
2021
Abstract Purpose The present study tested and compared the biomechanical properties of four different triplicate graft tendon techniques. Methods 32 tripled tendons from the common extensor muscle of bovine fingers were tested on a material testing machine, passing the end loop over a metal rod of a clevis connected to the load cell on the upper side, and fixing the lower end to a clamp. The samples were divided into four groups: (A) tripled with a free end sutured only to one of the two fixed bundles (B) tripled with a free end positioned between the two fixed strands and sutured to both (C) tripled with an S-shape and all the three strands sutured together at the upper and lower extremiti…
Safety and efficacy of MitraClip™ therapy in patients with severely impaired left ventricular ejection fraction: results from the German transcathete…
2017
Aims The aim of the present study was to assess the safety and efficacy of percutaneous mitral valve repair using the MitraClip™ device in patients with severely reduced systolic left ventricular (LV) function. Methods and results Among 777 MitraClip™ implantations included in the German mitral valve registry, we identified 256 patients suffering from severely reduced LV function [ejection fraction (EF) 50%) and 280 patients presenting with an EF 30–50% prior to MitraClip™ therapy. High procedural success rates, low periprocedural complication rates, and low residual mitral regurgitation grades at discharge were achieved throughout all groups. In-hospital mortality was low and comparable in…
Impact of left atrial diameter on outcome in patients undergoing edge-to-edge mitral valve repair: results from the German TRAnscatheter Mitral valve…
2020
Abstract Background Left atrium (LA) dimension is a marker of disease severity and outcome in primary and secondary mitral regurgitation. In transcatheter mitral valve repair LA enlargement might additionally impact on device handling and technical success through an altered anatomy and atrial annular dilatation. Methods Data from the multicenter German transcatheter mitral valve intervention registry “TRAMI” were used to analyse the association of baseline LA diameter by tertiles and efficacy, safety and long-term clinical outcome in patients undergoing edge-to-edge repair with the MitraClip. Results In 520 of 843 patients prospectively enrolled in TRAMI baseline LA diameter were reported …
Mitral valve therapy still surgical?
2015
Mitral regurgitation (MR) is the second most common valvular heart disease after aortic valve stenosis. With increased understanding of the heterogenic pathophysiology of MR, cardiac surgeons have developed various techniques that increase the likelihood of successful mitral valve repair (MVR). Nowadays, a rate of repair >90% may be reached in some mitral valve reference centres. In recent years, the introduction of transcatheter mitral valve intervention techniques has opened up new frontiers in mitral therapy, specifically in patients at high risk for standard surgery. Current percutaneous technologies for MVR have been developed on the basis of some of the surgical principles. Based on c…