Search results for "ANALYZER"
showing 10 items of 123 documents
A fully-digital realtime SoC FPGA based phase noise analyzer with cross-correlation
2017
We report on a fully-digital and realtime operation of a phase noise analyzer using modern digital techniques with cross-correlation. With the advent of system on chip field-programmable gate arrays (SoC FPGAs) embedding hard core central processing unit, coprocessor and FPGA onto a single integrated circuit, the building of sensitive analysis devices for Time & Frequency research is made accessible at virtually no cost and benefits from reconfigurability. Used with high-speed digitizers we have successfully implemented a four-channel system whose preliminary results at 10 MHz shows a residual white noise floor < −185 dBrad2/Hz up to 5 MHz off the carrier, and flicker < −127 dBrad2/Hz using…
Development of hard x-ray photoelectron SPLEED-based spectrometer applicable for probing of buried magnetic layer valence states
2016
Abstract A novel design of high-voltage compatible polarimeter for spin-resolved hard X-ray photoelectron spectroscopy (Spin-HAXPES) went into operation at beamline BL09XU of SPring-8 in Hyogo, Japan. The detector is based on the well-established principle of electron diffraction from a W(001) single-crystal at a scattering energy of 103.5 eV. It's special feature is that it can be operated at a high negative bias potential up to 10 kV, necessary to access the HAXPES range. The polarimeter is operated behind a large hemispherical analyzer (Scienta R-4000). It was optimized for high transmission of the transfer optics. A delay-line detector (20 mm dia.) is positioned at the exit plane of the…
First in-situ measurements of plume chemistry at mount garet volcano, island of gaua (Vanuatu)
2020
Recent volcanic gas compilations have urged the need to expand in-situ plume measurements to poorly studied, remote volcanic regions. Despite being recognized as one of the main volcanic epicenters on the planet, the Vanuatu arc remains poorly characterized for its subaerial emissions and their chemical imprints. Here, we report on the first plume chemistry data for Mount Garet, on the island of Gaua, one of the few persistent volatile emitters along the Vanuatu arc. Data were collected with a multi-component gas analyzer system (multi-GAS) during a field campaign in December 2018. The average volcanic gas chemistry is characterized by mean molar CO2/SO2, H2O/SO2, H2S/SO2 and H2/SO2 ratios …
Validation of Using Smartphone Built-In Accelerometers to Estimate the Active Energy Expenditures of Full-Time Manual Wheelchair Users with Spinal Co…
2021
[EN] This study aimed to investigate the validity of using built-in smartphone accelerometers to estimate the active energy expenditures of full-time manual wheelchair users with spinal cord injury (SCI). Twenty participants with complete SCI completed 10 5-min daily activities that involved the upper limbs, during which their oxygen consumption and upper limb activity were registered using a portable gas analyzer and a smartphone (placed on the non-dominant arm), respectively. Time series of 1-min averaged oxygen consumption and 55 accelerometer variables (13 variables for each of the four axes and three additional variables for the correlations between axes) were used to estimate three mu…
Sensing gastric cancer via point‐of‐care sensor breath analyzer
2021
Background Detection of disease by means of volatile organic compounds from breath samples using sensors is an attractive approach to fast, noninvasive and inexpensive diagnostics. However, these techniques are still limited to applications within the laboratory settings. Here, we report on the development and use of a fast, portable, and IoT-connected point-of-care device (so-called, SniffPhone) to detect and classify gastric cancer to potentially provide new qualitative solutions for cancer screening. Methods A validation study of patients with gastric cancer, patients with high-risk precancerous gastric lesions, and controls was conducted with 2 SniffPhone devices. Linear discriminant an…
Non-contact breath sampling for sensor-based breath analysis
2019
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a…
Microcentrifuge or Automated Hematological Analyzer to Assess Hematocrit in Exercise? Effect on Plasma Volume Loss Calculations
2016
The assessment of plasma volume loss (∆PV) induced by exercise can be estimated from changes in hematocrit (Htc) and hemoglobin (Hb), and it is essential when investigating the metabolic or biologic response to exercise of circulating biomarkers. We aimed to ascertain whether the estimation of ∆PV may differ when Hb and Htc are determined by automated hematological analyzer (AHA) versus manual methods. Twenty-five healthy male subjects performed a maximal running incremental exercise. Blood samples were taken before exercise, immediately after exercise, and after a 30-min recovery. Hb and Htc (Htc-AHA) were determined by an AHA. Htc was also determined by microcentrifugation (Htc-M). The ∆P…
Un approccio semplificato per il calcolo del load flow nelle smart grids basato su misure distribuite in bassa tensione
2017
I sistemi di misura distribuiti sono alla base delle "smart distribution grids", ove la crescente presenza di generazione distribuita e sistemi di accumulo e la conseguente transizione verso sistemi attivi rendono necessarie funzionalità avanzate di monitoraggio, controllo e gestione delle reti. In tale contesto, un elemento essenziale è l'analisi dei flussi di potenza, che, com'è noto, può essere effettuata tramite algoritmi di load flow, noti il modello della rete e le potenze generate/assorbite nei vari nodi. Per la misura di tali grandezze sulla media tensione (MT), si possono utilizzare diversi strumenti (quali phasor measurement units, smart meters, power quality analyzers), che però …
Un metodo basato su misure distribuite in bassa tensione per il calcolo del load flow nelle smart grids
2016
Con la diffusione della generazione distribuita nei sistemi elettrici di distribuzione e la conseguente loro transizione verso reti attive, è diventato essenziale disporre di opportuni sistemi per il monitoraggio, il controllo e la gestione delle retistesse. In questo ambito, l'unità GMEE di Palermo, in collaborazione con l'ISSIA-CNR e la STMicroelectronics, da alcuni anni si occupa dello sviluppo di sistemi di misura e comunicazione per lo sviluppo delle "smart distribution grids". In particolare, per quanto riguarda il monitoraggio della rete, lo studio è stato focalizzato sull'analisi dei flussi di potenza, che, noti il modello della rete e le potenze generate o assorbite nei vari nodi, …
Effective broadband refractive index retrieval by a white light optical particle counter.
2009
A new approach to retrieve the effective broadband refractive indices (nbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) is presented. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties. With the obtained nbroad,eff, WELAS aerosol size distributions can be corrected. Therefore, this method can be used for instrument calibration in both laboratory and field measurements. The retrieved effective broadband refractive indices for the scattering aerosols we…