Search results for "ANALYZER"
showing 10 items of 123 documents
The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.
2015
Abstract Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC–MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021 μg kg −1 and a limit of quantification of 0.071 μg kg −1 . The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9 μg kg −1 , indic…
Nuts and dried fruits: Natural occurrence of emerging Fusarium mycotoxins
2013
Abstract The occurrence of enniatins (ENs) and beauvericin (BEA) in nuts, dried fruits and dates available in Valencia (Spain) was surveyed in this study. To do this, seventy-four samples of nuts, dried fruits and dates were analyzed for the determination of mycotoxin contamination. Mycotoxins were identified and quantified using an ultrasonic-C18 extraction and LC–MS/MS with a triple quadrupole (QqQ) mass analyzer. The frequencies of contamination of nuts, shell, dried fruits and dates were 50%, 80%, 35.7% and 83.3%, respectively. Enniatin A (ENA) was the most predominant EN found in nuts (45.2%) while ENB was the most common EN found in dates (58.3%). The analytical results of the shell s…
Effects of soil gas permeability and recirculation flux on soil CO2 flux measurements performed using a closed dynamic accumulation chamber
2009
Abstract Dynamic accumulation chamber methods have been extensively used to estimate the total output of CO2 released from active volcanic area. In order to asses the performance and reliability of a closed dynamic system several tests were carried out with different soil permeabilities and soil CO2 fluxes. A special device was used to create a constant one-dimensional CO2 flux through a soil column with a known permeability. Three permeabilities were investigated, ranging between 3.6 × 10− 2 and 3.5 × 10 μm2, as were several CO2 fluxes (ranging between 1.1 × 10− 6 and 6.3 × 10− 5 kg m− 2 s− 1). The results highlight that the accuracy of soil CO2 flux measurements strictly depends on the so…
Liquid structure and dynamics in the choline acetate:urea 1:2 deep eutectic solvent
2021
We report on the thermodynamic, structural, and dynamic properties of a recently proposed deep eutectic solvent, formed by choline acetate (ChAc) and urea (U) at the stoichiometric ratio 1:2, hereinafter indicated as ChAc:U. Although the crystalline phase melts at 36-38 degrees C depending on the heating rate, ChAc:U can be easily supercooled at sub-ambient conditions, thus maintaining at the liquid state, with a glass-liquid transition at about -50 degrees C. Synchrotron high energy x-ray scattering experiments provide the experimental data for supporting a reverse Monte Carlo analysis to extract structural information at the atomistic level. This exploration of the liquid structure of ChA…
Isotope shifts and hyperfine structure in the transitions of stable calcium isotopes and calcium-41
1998
Isotope shifts and hyperfine structure in the 4s2 1S0 → 4s4p 1P1 and 4s2 1S0 → 4s4d 1D2 transitions of calcium have been measured with high-precision laser spectroscopy. Calcium atoms in an atomic beam were excited with single-frequency cw dye and titanium sapphire lasers and then photoionized with the 363.8 nm or 514.5 nm line of an argon ion laser. The resulting ions were analyzed and detected with a quadrupole mass spectrometer. Isotope shifts for all stable calcium isotopes and the radionuclide 41Ca have been measured in both transitions. The corresponding field shift and specific mass shift coefficients as well as hyperfine structure constants for the isotopes 41, 43Ca have been derive…
Ultratrace analysis of calcium with high isotopic selectivity by diodelaser resonance ionisation mass spectrometry
1997
A resonance ionisation mass spectrometer for the ultratrace determination of calcium isotopes is presented. It achieves high overall efficiency, ultra-high isotopic abundance sensitivity of more than 1010 and complete suppression of isobars. The system can be used for isotope ratio studies on stable and long-lived trace isotopes with the final goal of radiodating via 41Ca-determination. For the different applications optical one-, two- or three-step resonance excitation and subsequent ionisation is applied using simple and inexpensive diodelasers. Additional mass analysis is accomplished in a commercial quadrupole mass spectrometer. The experimental set-up and first results on synthetical a…
The Association between Cardiorespiratory Fitness and Gut Microbiota Composition in Premenopausal Women
2017
Abstract The aim of this study was to investigate the association between cardiorespiratory fitness and gut microbiota composition in premenopausal women. The participants consisted of 71 premenopausal Finnish women (aged 19–49 years). Gut microbiota were analyzed using flow cytometry, 16S rRNA gene hybridization and DNA-staining. Maximum oxygen uptake (VO₂ₘₐₓ) was assessed by respiratory gas analyzer and body composition by Bioimpdance. We found that participants with low VO₂ₘₐₓ had lower Bacteroides, but higher Eubacterium rectale-Clostridium coccoides than the high VO₂ₘₐₓ group (p < 0.05 for all). VO₂ₘₐₓ was inversely associated with EreC (r = −0.309, p = 0.01) but not with other bact…
Time-restricted eating effects on performance, immune function, and body composition in elite cyclists: a randomized controlled trial.
2020
Abstract Background Although there is substantial interest in intermittent fasting as a dietary approach in active individuals, information regarding its effects in elite endurance athletes is currently unavailable. The present parallel randomized trial investigated the effects of a particular intermittent fasting approach, called time-restricted eating (TRE), during 4 weeks of high-level endurance training. Methods Sixteen elite under-23 cyclists were randomly assigned either to a TRE group or a control group (ND). The TRE group consumed 100% of its estimated daily energy needs in an 8-h time window (from 10:00 a.m. to 6:00 p.m.) whilst energy intake in the ND group was distributed in 3 me…
Anterior Segment Biometry and Their Correlation with Corneal Biomechanics in Caucasian Children.
2018
Purpose: To assess the relationship between the corneal biomechanical parameters and the anterior segment parameters in Caucasian children. Methods: This study included 293 eyes from 293 healthy children aged between 6 and 17 years. Corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer, axial length (AL) with IOLMaster and the anterior segment with Pentacam. Anterior segment parameters obtained were the following: central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), anterior chamber volume (ACV) and mean anterior and posterior keratometry. Two multiple linear regression models were constructed to assess th…
Gas Transport in Mixed Matrix Membranes: Two Methods for Time Lag Determination
2020
The most widely used method to measure the transport properties of dense polymeric membranes is the time lag method in a constant volume/pressure increase instrument. Although simple and quick, this method provides only relatively superficial, averaged data of the permeability, diffusivity, and solubility of gas or vapor species in the membrane. The present manuscript discusses a more sophisticated computational method to determine the transport properties on the basis of a fit of the entire permeation curve, including the transient period. The traditional tangent method and the fitting procedure were compared for the transport of six light gases (H2, He, O2, N2, CH4, and CO2) and ethane an…