Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes

2009

To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyHyperopia030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens

2019

<b><i>Purpose:</i></b> To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). <b><i>Methods:</i></b> Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m<sup>2</sup>), and defocus curve…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignRefraction Ocularlaw.inventionCellular and Molecular NeuroscienceLens Implantation IntraocularlawOphthalmologyHumansMedicineContrast (vision)In patientRetrospective Studiesmedia_commonVision BinocularColor Visionbusiness.industryGeneral MedicinePresbyopiaMiddle Agedmedicine.diseaseMultifocal Intraocular Lenseseye diseasesSensory SystemsLens (optics)OphthalmologyVisual functionFemalemedicine.symptombusinessFollow-Up StudiesPhotopic visionOphthalmic Research
researchProduct

Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity

2008

A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best c…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensPupilContrast SensitivityCorneaLens Implantation IntraocularOphthalmologyCorneamedicineHumansContrast (vision)media_commonPhacoemulsificationbusiness.industryMiddle AgedCataract surgeryRefractive Errorseye diseasesSensory SystemsOphthalmologyLeft eyeSpherical aberrationmedicine.anatomical_structureSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study

2012

PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedicine.medical_treatmentVisual AcuityIntraocular lensFirst year of lifeAphakia PostcataractCataract ExtractionAphakiaCataractCataractsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryInfant NewbornInfantArticlesCataract surgerymedicine.diseaseRefractive ErrorsAxial elongationeye diseasesSurgeryContact lensTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

Pseudoaccommodating intraocular lens implantation in patients with irregular nonreactive pupils.

2007

We report 3 patients implanted with the AcrySof ReSTOR pseudoaccommodating intraocular lens (IOL) who had irregular nonreactive pupils as a consequence of pupil stretching during phacoemulsification. Despite the pupils, the visual acuity at distance and near was not compromised. The outcome in these cases suggests that an irregular nonreactive pupil is not an exclusion criterion for pseudoaccommodating IOL implantation.

Malemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentIntraocular lensPupilLens Implantation IntraocularPupil DisordersOphthalmologyMedicineHumansIn patientAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryAccommodation OcularPhacoemulsificationeye diseasesSensory SystemsOphthalmologySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery.

2009

PURPOSE To investigate if implantation of a far dominant refractive multifocal intraocular lens (IOL) in one eye and a near dominant diffractive multifocal IOL in the fellow eye improves range of vision following cataract surgery. METHODS This was a prospective, nonrandomized, case-control study involving 20 patients (40 eyes) scheduled for cataract surgery. Inclusion criteria were bilateral cataracts, minimum age 50 years, availability for follow-up visits, and informed consent. All patients received a far dominant refractive multifocal IOL (ReZoom, Abbott Medical Optics) in their dominant eye and a near dominant diffractive multifocal IOL (Tecnis ZM900, AMO) in their nondominant eye. Preo…

Malemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityAfter cataractProsthesis DesignRefraction OcularOcular dominance03 medical and health sciences0302 clinical medicineOphthalmologyMedicineHumansPostoperative PeriodProspective StudiesAgedAged 80 and overLenses IntraocularVision Binocularbusiness.industryGeneral MedicineMultifocal intraocular lensCataract surgeryMiddle AgedRefractioneye diseasesBilateral CataractsOphthalmologyVisual functionCase-Control Studies030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesEuropean journal of ophthalmology
researchProduct

Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review

2003

Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVision DisordersVisual AcuityIntraocular lensSalt lakeLens Implantation IntraocularDevice removalOphthalmologymedicineHumansDevice RemovalAgedAged 80 and overLenses IntraocularPhacoemulsificationElectron probe microanalysisbusiness.industryCalcinosisPhacoemulsificationeye diseasesSensory SystemsProsthesis FailureOphthalmologyIntraocular lensesCalciumFemaleSurgerysense organsBrunescent cataractmedicine.symptombusinessElectron Probe MicroanalysisJournal of Cataract &amp; Refractive Surgery
researchProduct

Refractive Lens Exchange with Foldable Toric Intraocular Lens

2009

To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensVisual phenomenaAstigmatismRefractive lens exchangeRefraction OcularLens Implantation IntraocularSurveys and QuestionnairesOphthalmologyMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesOphthalmologyAlcon LaboratoriesEyeglassesPatient SatisfactionOptometryFemalesense organsmedicine.symptombusinessCorneal astigmatismAmerican Journal of Ophthalmology
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery