6533b86dfe1ef96bd12ca1aa
RESEARCH PRODUCT
Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens
José F. AlfonsoLuis Fernández-vega-cuetoRobert Montés-micóLuis Fernández-vegasubject
Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignRefraction Ocularlaw.inventionCellular and Molecular NeuroscienceLens Implantation IntraocularlawOphthalmologyHumansMedicineContrast (vision)In patientRetrospective Studiesmedia_commonVision BinocularColor Visionbusiness.industryGeneral MedicinePresbyopiaMiddle Agedmedicine.diseaseMultifocal Intraocular Lenseseye diseasesSensory SystemsLens (optics)OphthalmologyVisual functionFemalemedicine.symptombusinessFollow-Up StudiesPhotopic visiondescription
<b><i>Purpose:</i></b> To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). <b><i>Methods:</i></b> Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m<sup>2</sup>), and defocus curves were evaluated at 6-months. <b><i>Results:</i></b> Six months postoperatively, the mean binocular Snellen decimal CDVA and DCNVA were 0.94 ± 0.10 (ranging from 0.70 to 1.25) and 0.85 ± 0.13 (ranging from 0.63 to 1.00), respectively. At a distance, all patients showed a cumulative binocular distance-corrected visual acuity of 0.8 or better, and about 80% (<i>n</i> = 31) of the patients had a value of 1.0 (20/20). At near and intermediate distances, all patients showed a cumulative distance-corrected visual acuity of 0.5 (20/40) or better at 30, 40, 50, 60, and 70 cm. Specifically, 50 cm showed the highest percentage of patients with larger values of visual acuity (60% [<i>n</i> = 26] with 20/20). Defocus curve showed a wide range of useful vision with two peaks of best visual acuity at distance and at 50 cm, and the binocular distance contrast sensitivity was within normal limits. <b><i>Conclusions:</i></b> The outcomes of the present study show that the visual performance obtained with bilateral implantation of the trifocal aspheric AcrySofIQ PanOptix IOL is good at far, intermediate, and near distances.
| year | journal | country | edition | language |
|---|---|---|---|---|
| 2019-01-26 | Ophthalmic Research |