0000000000000024

AUTHOR

José F. Alfonso

showing 43 related works from this author

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

2018

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

1144ApertureZernike polynomialsmedicine.medical_treatmentintraocular lensIntraocular lensStandard deviationlaw.invention03 medical and health sciencessymbols.namesake0302 clinical medicineOpticslcsh:OphthalmologylawMedicinerepeatabilityoptical qualitybusiness.industryRepeatabilityOptical qualityToric lensLens (optics)Ophthalmologyin-vitro measurementslcsh:RE1-994030221 ophthalmology & optometrysymbolsbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

2013

PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …

AdultMalemedicine.medical_specialtyBiopticsOptics and PhotonicsPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentImplantable Collamer Lens (ICL)Keratomileusis Laser In SituVisual AcuityKeratomileusisAstigmatismExcimerPhakic intraocular lensRefraction OcularPhotorefractive KeratectomyCellular and Molecular NeuroscienceYoung AdultOpticsBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansDioptreImplantable collamer lensScience & TechnologyExcimer laserbusiness.industryAstigmatismMiddle Agedmedicine.diseaseSensory SystemsPhotorefractive keratectomyeye diseasesOphthalmologyImplantable Collamer LensTreatment OutcomeFemalebusinessGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.

2012

To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentCorneal StromaVision DisordersVisual AcuityComa (optics)Power vectorKeratoconusRefraction OcularCohort StudiesProsthesis ImplantationYoung AdultOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesAlpins methodAgedIntrastromal corneal ring segmentbusiness.industryCorneal TopographyProstheses and ImplantsMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologySurgeryFemalesense organsLaser TherapyCorneal ringbusinessJournal of cataract and refractive surgery
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

2007

To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…

MaleRefractive errormedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaEye diseasemedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensResidualVision disorderPostoperative ComplicationsApodizationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansProspective StudiesAgedLenses IntraocularMonocularbusiness.industryMiddle Agedmedicine.diseaseRefractive Errorseye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses.

2008

Purpose To compare visual acuity after bilateral implantation of 2 models of multifocal aspheric intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, and University of Valencia, Valencia, Spain. Methods Prospective study of patients who had bilateral implantation of an AcrySof ReSTOR SN6AD3 IOL (Group 1) or an Acri.LISA 366D IOL (Group 2). Six months postoperatively, binocular uncorrected and best corrected distance visual acuity, uncorrected-distance and best distance-corrected near visual acuity, best corrected intermediate visual acuity, and the defocus curve were measured in both IOL groups. Results Group 1 comprised 36 eyes (18 patients) and Group 2, 40…

Malemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresPseudophakiamedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignNear visual acuityFunctional LateralityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesIntermediate visual acuityOptometrySurgeryFemalemedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of a diffractive aspheric trifocal intraocular lens

2016

Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…

AdultMaleVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignRefraction OcularGlareContrast Sensitivity03 medical and health sciencesNear visionOcular physiology0302 clinical medicineLens Implantation IntraocularMedicineHumansProspective StudiesAgedLenses IntraocularVision BinocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationMiddle Agedeye diseasesOphthalmologyVisual function030221 ophthalmology & optometryOptometryFemalemedicine.symptombusinessBinocular vision030217 neurology & neurosurgeryPseudophakia
researchProduct

Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes

2009

To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyHyperopia030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.

2013

Purpose To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia. Setting Private practice, Oviedo, Spain. Design Case series. Methods This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively. Results The study enroll…

AdultMalemedicine.medical_specialtyRefractive errorIntraocular pressurePhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityCell CountPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineMyopiaHumansProspective StudiesProspective cohort studyDioptreIntraocular PressureAqueous flowbusiness.industryEndothelium CornealCorneal Endothelial Cell Lossmedicine.diseaseRefractive Errorseye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomePrivate practiceIridectomySurgeryFemalesense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.

2013

Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …

Adultmedicine.medical_specialtyIntraocular pressurePhakic Intraocular Lensesgenetic structuresVisual AcuitySpherical equivalentBiocompatible MaterialsCell CountRefraction OcularSafety indexCorneaYoung AdultLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreImplantable collamer lensEfficacy indexbusiness.industryEndothelium CornealMiddle Agedeye diseasesSensory SystemsPosterior chamber phakic intraocular lensEndothelial cell densityOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar

2008

Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…

luz dispersa que llega a la retina0303 health sciencesmedicine.medical_specialtyretinal straylightvisual performancegenetic structuresbusiness.industryCase Reportkeratoplastycalidad visualeye diseasesqueratoplastia03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologylcsh:RE1-994Ophthalmology030221 ophthalmology & optometrymedicinelcsh:QC350-467businesslcsh:Optics. LightCorneal Scar030304 developmental biologyOptometryJournal of Optometry
researchProduct

Agreement of white-to-white measurements with the IOLMaster 700, Atlas 9000, and Sirius systems

2018

Current advances in ocular surgery require the evaluation of differences in automated white-to-white (WTW) measurements between systems. We aim to analyze three different commonly used devices in clinical practice: the IOLMaster 700, the Atlas 9000, and the Sirius.Ninety right eyes of ninety healthy subjects were included. Measurements of WTW distances were taken with each device for all subjects in the same session and by the same observer. Statistical comparison was carried out by means of the rANOVA procedure and the Bonferroni post-hoc test. In addition, the Bland-Altman analysis was applied in order to perform pairwise comparisons.Average WTW values obtained by the IOLMaster 700, the A…

AdultMaleWhite to whitebusiness.industryOcular surgerySiriusBiomedical EngineeringOphthalmologic Surgical ProceduresGeneral MedicineMiddle AgedYoung Adult03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureAtlas (anatomy)030221 ophthalmology & optometrymedicineHumansOptometryFemaleSurgerybusiness030217 neurology & neurosurgeryOphthalmologic Surgical ProcedureDemographyExpert Review of Medical Devices
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens

2007

To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…

AdultMalemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationMonocularbusiness.industryDistance PerceptionPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyPostoperative visitOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes

2008

Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…

Refractive errormedicine.medical_specialtygenetic structuresbusiness.industrymedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensPresbyopiaMultifocal intraocular lensAstigmatismmedicine.diseaseeye diseasesSensory SystemsVision disorderOphthalmologyOphthalmologymedicineContrast (vision)Surgerymedicine.symptombusinessDioptremedia_commonJournal of Cataract and Refractive Surgery
researchProduct

Intermediate visual function with different multifocal intraocular lens models

2009

Purpose To compare visual acuity at different distances after bilateral implantation of 1 of 4 multifocal intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods This study evaluated consecutive patients who had bilateral implantation of a spherical multifocal IOL with a +4.00 diopter (D) addition (add) (AcrySof ReSTOR SN60D3) or an aspheric multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), +3.75 D add (Acri.LISA 366D), or +3.00 D add (AcrySof ReSTOR SN6AD1). Six months postoperatively, binocular measurement of corrected distance visual acuity (CDVA) at 4 m, corrected near visual acuity (CNVA) at 40 cm, and corrected intermediate visual …

Malemedicine.medical_specialtyVisual acuityDistance visual acuityPseudophakiagenetic structuresVisual AcuityFunctional LateralityContrast SensitivityCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansDioptreAgedLenses IntraocularVision Binocularbusiness.industryDistance PerceptionMiddle AgedMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureVisual functionOptometryFemaleSurgerysense organsmedicine.symptombusinessBinocular visionPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation

2008

Purpose: To evaluate distance, intermediate and near visual performance in patients who had undergone implantation of the multifocal aspheric AcrySof ReSTOR intraocular lens (IOL). Methods: Binocular best distance corrected visual acuity (BCVA) at high and low contrast [4 m], best distance corrected near visual acuity (BCNVA) [40 cm], intermediate visual acuity [80 and 60 cm], and distance contrast sensitivity (CS) under photopic [85 cd/m2] and mesopic [3 cd/m2] conditions, were measured in 36 eyes that underwent implantation of the AcrySof ReSTOR Aspheric IOL (SN6AD3). Results: At the 3-month postoperative visit, binocular BCVA was -0.058±0.091, 0.200±0.079, and 0.258±0.071 logMAR, for 100…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentdiffractionLIO multifocalIntraocular lenslcsh:OphthalmologyOphthalmologymedicinemultifocal IOLvisual functionlcsh:QC350-467In patientasfericidaddifracciónbusiness.industryfunción visualeye diseasesasphericityVisual functionlcsh:RE1-994OptometryOriginal Articlesense organsbusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.

2009

Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…

MaleVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensExtractionFunctional LateralityTratamiento médico0302 clinical medicineLens Implantation IntraocularMyopiaContrast (vision)MedicineRetinal-Detachmentmedia_commonVistaLenses IntraocularVision BinocularDistanceHigh myopiaRetinal detachmentGeneral MedicineMiddle AgedQualityTreatment OutcomeOftalmologíaFemalemedicine.symptomPhotopic visionRiskmedia_common.quotation_subjectProsthesis DesignContrast Sensitivity03 medical and health sciencesHumansMonocularPhacoemulsificationbusiness.industryMultifocal Iolmedicine.diseaseeye diseasesVisual PerformanceOphthalmology030221 ophthalmology & optometryOptometrysense organsbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Implantable collamer lens with central hole: 3-year follow-up.

2018

Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …

medicine.medical_specialtyDistance visual acuitygenetic structuresVisian ICLeducationEmmetropiaSpherical equivalentPhakic intraocular lensEndothelial cell count03 medical and health sciences0302 clinical medicineOphthalmologyMedicinehealth care economics and organizationsOriginal ResearchImplantable collamer lensbusiness.industryimplantable collamer lensClinical Ophthalmologyeye diseasesOphthalmologylong-term evaluation030221 ophthalmology & optometrybusinessphakic intraocular lens030217 neurology & neurosurgeryClinical ophthalmology (Auckland, N.Z.)
researchProduct

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

2007

To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityCorrelationLens Implantation IntraocularHumansMedicineContrast (vision)Prospective Studiesmedia_commonLenses Intraocularbusiness.industryPupilMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerysense organsSpatial frequencymedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual function comparison of 2 aspheric multifocal intraocular lenses

2011

To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Comparative case series.Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured.The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.0…

MaleVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensGlareContrast SensitivityLens Implantation IntraocularmedicineHumansContrast (vision)Prospective StudiesMathematicsmedia_commonLenses IntraocularPhacoemulsificationGlare (vision)Middle AgedMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyVisual functionOptometryFemaleSurgerysense organsmedicine.symptomPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual function after implantation of an aspheric bifocal intraocular lens.

2009

Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…

Malemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesMedicineContrast (vision)HumansProspective StudiesDioptremedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)Middle Agedeye diseasesSensory SystemsOphthalmologyPatient SatisfactionVisual DisturbanceOptometrySurgeryFemaleSpatial frequencybusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology
researchProduct

Femtosecond laser–assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty

2013

PURPOSE: To assess the visual and refractive outcomes of femtosecond laser-assisted implanta- tion of Ferrara-type intrastromal corneal ring segments (ICRS) in post-penetrating keratoplasty (PKP) eyes. SETTING: Instituto OftalmolFernOviedo, Spain. DESIGN: Cohort study. METHODS: Patients with previous PKP had ICRS implantation after femtosecond laser tunnel creation. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation. The power vector method was used to analyze refractive errors preoperatively and postoperatively. RESULTS: This study enrolled 32 eyes of 30 patients. The mean UDVA (Snell…

AdultMalemedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentVisual AcuitySpherical equivalentAstigmatismRefraction OcularPower vectorCorneal DiseasesCohort StudiesProsthesis ImplantationYoung AdultHigh astigmatismOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesIntrastromal corneal ring segmentbusiness.industryAstigmatismProstheses and ImplantsMiddle Agedmedicine.diseaseLaser assistedeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleSurgeryLaser Therapysense organsCorneal ringbusinessKeratoplasty PenetratingJournal of Cataract and Refractive Surgery
researchProduct

Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens

2019

<b><i>Purpose:</i></b> To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). <b><i>Methods:</i></b> Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m<sup>2</sup>), and defocus curve…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignRefraction Ocularlaw.inventionCellular and Molecular NeuroscienceLens Implantation IntraocularlawOphthalmologyHumansMedicineContrast (vision)In patientRetrospective Studiesmedia_commonVision BinocularColor Visionbusiness.industryGeneral MedicinePresbyopiaMiddle Agedmedicine.diseaseMultifocal Intraocular Lenseseye diseasesSensory SystemsLens (optics)OphthalmologyVisual functionFemalemedicine.symptombusinessFollow-Up StudiesPhotopic visionOphthalmic Research
researchProduct

Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis

2008

To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…

Malemedicine.medical_specialtyRefractive errorPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisIntraocular lensProsthesis DesignCataractPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometryFemaleLasers ExcimerSurgerysense organsbusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens

2009

Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …

MaleRefractive errormedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensContrast SensitivityVision disorderTonometry OcularLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraocular PressureDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryHipermetropíaPresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOftalmologíaOptometryFemalesense organsmedicine.symptombusinessPhotopic visionAmerican Journal of Ophthalmology
researchProduct

Effects of Ageing on the Anterior Segment of the Eye Structure and Function

2018

[Excerpt] The world will soon have more aged people than children and more people at extreme old age than ever before [1]. Improving quality of life as well as reducing severe disability due to age-related problems has become key for the health systems worldwide. The ageing of the world population has both structural and functional consequences for the human visual system; changes due to ageing occur in all the structures of the eye causing a variety of effects. Over the last few years, great advances in ophthalmic instrumentation allow the determination of ocular parameters to a level of detail without precedent. Such advances allowresearcherstodevelopspecificdevicesforvisualcorrection and r…

medicine.medical_specialtyScience & TechnologyArticle SubjectCiências Naturais::Ciências Físicasbusiness.industrymedia_common.quotation_subjectMEDLINE030204 cardiovascular system & hematology3. Good health03 medical and health sciencesOphthalmologyEditorial0302 clinical medicineText miningPhysical medicine and rehabilitationlcsh:Ophthalmologylcsh:RE1-994AgeingEye structureMedicineFunction (engineering)business030217 neurology & neurosurgerymedia_commonJournal of Ophthalmology
researchProduct

<p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>

2019

Purpose To assess visual and refractive results after bilateral implantation of a trifocal intraocular lens (IOL) in patients with hyperopia. Methods In a retrospective nonrandomized study, 196 eyes of 98 patients had bilateral implantation of a trifocal IOL. The Barrett Universal II formula was used for IOL power calculation. Eyes were divided into two groups for their analysis: low-moderate, with IOL power ranging from 22 to 26 D, and high, with IOL power ranging from 25 to 34 D. Refractive error was used to assess predictability, and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity values were used to assess efficacy and safety of the surgery. Results Six mo…

medicine.medical_specialtyRefractive errorDistance visual acuityVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentSpherical equivalentIntraocular lensPhacoemulsificationmedicine.diseaseeye diseases03 medical and health sciencesOphthalmology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineIn patientsense organsmedicine.symptombusiness030217 neurology & neurosurgeryClinical Ophthalmology
researchProduct