Search results for "Pseudophakia"

showing 10 items of 41 documents

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct

Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation

2011

PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…

AdultDepth of focusVisual acuityCorneal Wavefront AberrationPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityCorneaYoung AdultLens Implantation IntraocularCorneaRefractive surgerymedicineHumansDioptreLenses IntraocularDepth Perceptionbusiness.industryAblationRefractive Errorseye diseasesOphthalmologySpherical aberrationmedicine.anatomical_structureOptometryOftalmologíaSurgerysense organsmedicine.symptomDepth perceptionbusiness
researchProduct

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of a diffractive aspheric trifocal intraocular lens

2016

Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…

AdultMaleVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignRefraction OcularGlareContrast Sensitivity03 medical and health sciencesNear visionOcular physiology0302 clinical medicineLens Implantation IntraocularMedicineHumansProspective StudiesAgedLenses IntraocularVision BinocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationMiddle Agedeye diseasesOphthalmologyVisual function030221 ophthalmology & optometryOptometryFemalemedicine.symptombusinessBinocular vision030217 neurology & neurosurgeryPseudophakia
researchProduct

Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.

2009

To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …

AdultMalemedicine.medical_specialtyAgingVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityYoung AdultLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansAgedComaAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgeryFemalesense organsmedicine.symptombusinessPseudophakiaJournal of cataract and refractive surgery
researchProduct

Incidence of Retinal Detachment in Germany: Results from the Gutenberg Health Study

2020

<b><i>Purpose:</i></b> To investigate the incidence of retinal detachment in the German population and to assess potential risk factors. <b><i>Methods:</i></b> The Gutenberg Health Study is a population-based cohort study in Mainz, Germany, including subjects (<i>n</i> = 15,010) with an age range from 35 to 74 years at baseline examination. Study participants underwent a comprehensive ophthalmological examination including distant-corrected visual acuity, refraction and slit-lamp examination at baseline examination. A computer-assisted telephone interview was conducted after 2.5 and 5 years, and health events were recorded. The 5-y…

AdultMalemedicine.medical_specialtyVisual acuityPopulationVisual AcuityCohort Studieschemistry.chemical_compoundGermanyOphthalmologymedicineHumansCumulative incidenceeducationAgededucation.field_of_studybusiness.industryIncidenceIncidence (epidemiology)Retinal DetachmentRetinal detachmentRetinalGeneral MedicineMiddle Agedmedicine.diseaseSensory SystemsOphthalmologychemistryFemalemedicine.symptombusinessPseudophakiaCohort studyOphthalmologica
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct

Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.

2019

To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…

MaleCorneal Wavefront AberrationPseudophakiaMesopic visionZernike polynomialsmedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPupillaw.inventionsymbols.namesakeLens Implantation IntraocularlawmedicineHumansProspective StudiesRetinoscopyMathematicsAgedPhacoemulsificationmedicine.diagnostic_testKeratometerAberrometryMiddle AgedMultifocal Intraocular LensesSensory SystemsOphthalmologyAutorefractorsymbolsOptometrySurgeryFemalePhotopic visionJournal of cataract and refractive surgery
researchProduct