Retinal straylight in patients with monofocal and multifocal intraocular lenses
2007
Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…
Imaging quality of multifocal intraocular lenses: automated assessment setup
2012
[EN] Purpose: A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. Methods: The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial corneas, to optimise the axial resolution in the sampling of the MTF of the MIOL under test, and different pupils, to test the dependence of the optical performance of the MIOL on the eye pupil diameter. Results: The performance and sensitivity of the apparatus is tested with different commercial MIOLs…
Deliberate Arterial Hypotension Does Not Reduce Intraocular Pressure in Pigs
1992
Among the accepted advantages of general anesthesia in ophthalmic surgery is improved control of intraocular pressure (IOP). Although standard textbooks advocate deliberate arterial hypotension to facilitate intraocular surgery by reducing IOP, scientific proof of such an effect is lacking. The authors investigated effects of induced arterial hypotension on IOP in an anesthetized porcine model. Forty-two piglets were anesthetized with piritramide, were placed in the prone position, and had the anterior chamber of one eye punctured with a small Teflon cannula to measure IOP. Six pigs were used in a pilot study to establish dose-response relationships for the hypotensive agents; 36 pigs were …
Topical glaucoma medications – Clinical implications for the ocular surface
2022
Glaucoma is a leading cause of irreversible blindness. The use of topical eye drops to reduce intraocular pressure remains the mainstay treatment. These eye drops frequently contain preservatives designed to ensure sterility of the compound. A growing number of clinical and experimental studies report the detrimental effects of not only these preservatives but also the active pharmaceutical compounds on the ocular surface, with resultant tear film instability and dry eye disease. Herein, we critically appraise the published literature exploring the effects of preservatives and pharmaceutical compounds on the ocular surface. publishedVersion
Optical performance of two new trifocal intraocular lenses: through-focus modulation transfer function and influence of pupil size
2013
Background To compare the in vitro optical quality of two new trifocal intraocular lenses at different focal points as a function of pupil size. Methods Two intraocular lenses having different design approaches were evaluated: the AT LISA tri 839MP with a trifocal diffractive design, and the FineVision, which combines two distinct apodized bifocal diffractive profiles resulting in three foci. A PMTF optical bench was used to assess the intraocular lenses' performance, and as optical quality metrics, the through-focus modulation transfer function was selected; that is, it was measured at 10 focal points and for four different apertures (2.0, 3.0, 3.75 and 4.5 mm). Results For both lenses, th…
Comparison of the Ultraviolet Light Filtering across Different Intraocular Lenses.
2018
SIGNIFICANCE We have analyzed the ultraviolet transmittance of some commercial intraocular lenses (IOLs). The results show differences of wavelength cutoff among them. PURPOSE The purpose of this study was to measure and compare the ultraviolet light transmittance of different IOLs made out of acrylic hydrophobic, hydrophilic, and hydrophilic with hydrophobic surface materials from different manufacturers. METHODS The spectral transmission curves of eight monofocal IOLs with the same dioptric power of +20.0 diopters were measured using a PerkinElmer Lambda 35 ultraviolet/visible spectrometer. Two IOLs of each type were tested three times. The ultraviolet cutoff wavelength at 10% transmissio…
Photoprotection and photoreception of intraocular lenses under xenon and white LED illumination.
2016
Objective. To analyze the photoprotection and phototransmission that various intraocular lenses (10Ls) provide under the illumination of a xenon (Xe) lamp and white LEDs (light emitting diode). Methods. The spectral transmission curves of six representative 10Ls were measured using a Perkin-Elmer Lambda 35 UV/VIS spectrometer. Various filtering simulations were performed using a Xe lamp and white LEDs. The spectral emissions of these lamps were measured with an ILT-950 spectroradiometer. Results. The 10Ls analyzed primarily show transmission of nearly 100% in the visible spectrum. In the ultraviolet (UV) region, the filters incorporated in the various 10Ls did not filter equally, and some o…
In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.
2015
Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.
2016
Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…