Search results for "ARTERIAL"
showing 10 items of 714 documents
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
2014
Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physici…
Relationship of Metabolic Syndrome With Pulse Pressure in Patients With Essential Hypertension
2006
BACKGROUND: Pulse pressure is largely dependent on arterial stiffness. Recent studies have documented reduced large artery compliance in nondiabetic subjects with metabolic syndrome (MS). The aim of our study was to analyze, in a group of patients with essential hypertension and without diabetes mellitus, the influence of MS on clinic and 24-h pulse pressures. METHODS: A total of 528 hypertensive subjects, aged 18 to 72 years, who were free of cardiovascular and renal diseases were enrolled. Of the subjects, 41% had MS. In all subjects routine blood chemistry, echocardiographic examination, and 24-h ambulatory blood pressure monitoring were performed. RESULTS: When compared with subjects wi…
Ambulatory Arterial Stiffness Index (AASI) is Unable to Estimate Arterial Stiffness of Hypertensive Subjects: Role of Nocturnal Dipping of Blood Pres…
2018
BACKGROUND: Ambulatory Arterial Stiffness Index (AASI) has been proposed as an indirect and simpler method to estimate the Arterial Stiffness (AS). AASI, calculated from a set of data collected during a 24-hours ambulatory blood pressure monitoring (ABPM), is defined as 1 minus the regression slope of diastolic on systolic blood pressure (BP) values. For a given increase in diastolic BP, the increase in systolic BP is smaller in a compliant compared to a stiff artery; the stiffer the arterial tree, the closer AASI is to 1. AASI was demonstrated to predict cardiovascular mortality, cerebrovascular events and to be associated with target organ damage. Taking into account the almost complete a…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.
2011
International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…
Erectile dysfunction is associated with low total serum testosterone levels and impaired flow-mediated vasodilation in intermediate risk men accordin…
2015
Background: The role erectile dysfunction (ED) coupled with low testosterone levels as early markers of atherosclerosis is not well understood. Objectives: To analyze the relationship between serum testosterone levels with both ED and brachial artery flow-mediated vasodilation (FMD), in a primary prevention sample of men. Methods: We enrolled 802 asymptomatic, intermediate CV risk patients, according to the Framingham Risk Score, aged 40e80 years, who underwent the ultrasound examination of FMD, the evaluation of ED and the assessment of total serum testosterone levels. Results: Testosterone levels correlated both with FMD (r ¼ 0.85; p < 0.0001) and IIEF-5 score (rs ¼ 0.65; p < 0.0001…
Noninvasive peripheral vascular function and atrial fibrillation in the general population.
2019
Background Arterial stiffness is a strong predictor of atrial fibrillation in the community. Whether noninvasively measured conduit artery function and peripheral vascular reactivity are related to atrial fibrillation remains unknown. Methods and results In 15 010 individuals of the population-based Gutenberg Health Study, mean age 55 ± 11 years, 50.5% men, we determined noninvasive vascular function by flow-mediated dilation (FMD) and peripheral arterial tonometry (PAT) in relation to manifest atrial fibrillation (N = 466). Patients with atrial fibrillation exhibited a higher mean brachial artery diameter [4.81 mm (4.17, 5.33) in atrial fibrillation vs. 4.31 mm (3.67, 4.93)] and baseline p…
Evaluation of posttreatment response of hepatocellular carcinoma: comparison of ultrasonography with second-generation ultrasound contrast agent and …
2010
We evaluated the ability of one-month follow-up contrast-enhanced ultrasound (CEUS) with second-generation contrast agent in monitoring radio frequency ablation (RFA) and transcatheter arterial chemoembolization (TACE) treatments of hepatocellular carcinoma (HCC). One-hundred forty-eight HCCs were studied using CEUS: 110 nodules were treated with RFA [41/110 RFA were performed using a pretreatment and an immediate postablation evaluation using CEUS (group 1); 69/110 using only US guidance (group 2)] and 38 nodules treated with TACE. For statistical analysis, McNemar test was used. Overall complete response was observed in 107/148 nodules (92/110 treated with RFA and 15/38 with TACE). A bett…
Noninvasive assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-con…
2013
Background— Right heart catheterization is the gold standard for assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension. To date, MRI has not been able to produce precise measurements of mean pulmonary arterial pressure (mPAP). The purpose of the study was to create a model for estimating mPAP and pulmonary vascular resistance in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-contrast MRI (PC-MRI) and to correlate the results with simultaneously acquired, invasive catheter-based measurements (simultaneously measured mPAP) and with right heart catheterization measurements. Methods and Results— A tota…
Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.
2017
Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive…