Search results for "ASPIRATION"
showing 10 items of 118 documents
Ultrasound-guided fine-needle aspiration cytology in the early detection of melanoma metastases.
2000
BACKGROUND. The early detection and treatment of tumor recurrences in melanoma patients is dependent on reliable, sensitive, and specific techniques to verify suspected tumor metastases. As of now, fine-needle aspiration cytology (FNAC) has yet to establish itself in the routine follow-up of melanoma patients. METHODS. FNAC procedures were performed in melanoma patients with palpable tumors or nonpalpable, ultrasonically suspicious lesions. Cytodiagnostic evaluation of fine-needle samples obtained from suspicious lesions was performed morphologically. Findings were validated either by histopathologic diagnosis or prolonged clinical follow-up. RESULTS. The cytologic examination of 739 FNACs …
Fine-Needle Aspiration (FNAB) Molecular Analysis for the Diagnosis of Papillary Thyroid Carcinoma through BRAFv600E mutation and RET/PTC rearrangement
2007
Objective: To evaluate BRAFV600E mutation on consecutive fine-needle aspiration biopsy (FNAB) specimens in order to assess FNAB’s usefulness in preoperative papillary thyroid carcinoma (PTC) diagnosis with the contemporaneous analysis of RET=PTC1 and RET=PTC3 rearrangements obtained from ex vivo thyroid nodules. Design: Thyroid FNABs from 156 subjects with nodules and 49 corresponding surgical samples were examined for the presence of BRAF mutation by real-time allele-specific polymerase chain reaction, confirmed with the use of a laser pressure catapulting system. Samples were also examined for RET=PTC rearrangements. The results were compared with the cytological diagnosis and histopathol…
Les parcours scolaires des jeunes issus de l'immigration. Quelles aspirations ? Quelles réalités ?
2008
08057
Aspirations des familles et parcours scolaires des enfants issus de l'immigration : des différences sexuées ?
2006
06068
Wind speed and temperature trends impacts on reference evapotranspiration in Southern Italy
2014
In this study, the impacts of both temperature and wind speed trends on reference evapotranspiration have been assessed using as a case study the Southern Italy, which present a wide variety of combination of such climatic variables trends in terms of direction and magnitude. The existence of statistically significant trends in wind speed and temperature from observational datasets, measured in ten stations over Southern Italy during the period 1968–2004, has been investigated. Time series have been examined using the Mann–Kendall nonparametric statistical test in order to detect possible evidences of wind speed and temperature trends at different temporal resolution and significance level.…
Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT
2017
BACKGROUND AND PURPOSE: Large-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND METHODS: We established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration…
Under Pressure: Comparison of Aspiration Techniques for Endovascular Mechanical Thrombectomy.
2018
BACKGROUND AND PURPOSE: Blood flow should be interrupted during mechanical thrombectomy to prevent embolization of clot fragments. The purpose of our study was to provide a handy overview of the most common aspiration devices and to quantify their flow characteristics. MATERIALS AND METHODS: We assessed volumetric flow rates generated by a 60-mL VacLok vacuum pressure syringe, a Pump MAX aspiration pump, and a Dominant Flex suction pump connected to the following: 1) an 8F long sheath, 2) an 8F balloon-guide catheter, 3) an ACE 64 distal aspiration catheter, and 4) an AXS Catalyst 6 Distal Access Catheter. We used a water/glycerol solution, which was kept at a constant temperature of 20°C (…
Interactive Decision Aids
2011
Decision support systems assist people in making a decision or choosing a course of action in a nonroutine situation that requires judgment (Haubl and Trifts 2000; Kasper 1996). In online webstores, vendors can easily offer highly interactive types of decision support. These co-called interactive decision aids (IDA) “help consumers in making informed purchase decisions amidst the vast availability of online product offerings” (Wang and Benbasat 2009, p. 3). However, the application of IDA is not restricted to purchase decisions. They are general enough to be of use in any kind of choice task where alternatives are known.
INTACMATO: An IIMT-Prototype
2011
In the previous chapter, we pointed out that although users evaluate IIMT very positively, only a limited number of IIMT are offered. We assume that the main reason for this is that online sellers do not know which IIMT they should offer and what they should exactly look like. We address these two aspects in this chapter. Firstly, we review literature on IDA in the field of human interaction. We discuss several drawbacks of current approaches as well as the resulting requirements for the design of IIMT. Secondly, we break down observed decision-making behavior into typical steps decision makers apply in their decision processes. These steps indicate which IIMT would offer appropriate decisi…
Unraveling the behavior of oral drug products inside the human gastrointestinal tract using the aspiration technique: History, methodology and applic…
2020
Fluid sampling from the gastrointestinal (GI) tract has been applied as a valuable tool to gain more insight into the fluids present in the human GI tract and to explore the dynamic interplay of drug release, dissolution, precipitation and absorption after drug product administration to healthy subjects. In the last twenty years, collaborative initiatives have led to a plethora of clinical aspiration studies that aimed to unravel the luminal drug behavior of an orally administered drug product. The obtained drug concentration-time profiles from different segments in the GI tract were a valuable source of information to optimize and/or validate predictive in vitro and in silico tools, freque…