Systematic Study of Several Causes and Effects Due to Absorbent Blanks in Determinations of One Analyte

1999

A systematic study is performed about several factors involved in the measurements when a absorbent blank is used, as molar absorption coefficient of the formed complex, absorbance of the blank at the measured wavelength, and kind of spectrophotometer used (conventional double-beam or diode-array). It is proved that the usual methodology, measuring against reagent blank, produces less accurate measurements than those obtained against solvent blank. On the other hand, use of the H-Point standard additions method provides always equal or better results than the best ones obtained at single wavelengths by using measurements against solvent bank, at the maximum of the formed complex. To test th…

AbsorbanceAnalyteChemistryReagentStandard additionAnalytical chemistryCalibrationArsenazo IIIMolar absorptivityBlankAnalytical ChemistryMicrochimica Acta
researchProduct

Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations

2004

Abstract A series of approaches have been assayed for FTIR determination of Mancozeb in several solid commercial fungicides using different calibration strategies. The simplest procedure was based on the use of the ratio between the absorbance of a characteristic band of Mancozeb and that of a KSCN internal standard measured in the FTIR spectra obtained from KBr pellets. It was employed the quotient between peak height absorbance values at 1525 cm−1 for Mancozeb and 2070 cm−1 for KSCN. In these conditions a precision as relative standard deviation (RSD) of 0.6% and a relative accuracy error of 0.8% (w/w) were found. For complex formulations, containing other compounds with characteristic ab…

AbsorbanceChemistryStandard additionPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyMancozebFourier transform spectroscopyStandard deviationAnalytical ChemistryTalanta
researchProduct

Synthesis and Physical Stability of Novel Au-Ag@SiO<SUB>2</SUB> Alloy Nanoparticles

2012

The present study describes the synthesis of nanoparticles of silver-gold alloys and with their electrokinetic and spectroscopic characterisation. The synthesis was made in two steps. In the first step silver nanoparticles coated with silica (Ag@SiO2) were synthesised using a novel method assisted by laser ablation. The second step consisted on the introduction of KAuCl4 in the colloidal solution of Ag@ SiO2 nanoparticles in order to obtain silica-coated silver-gold alloy nanoparticles. The changes of colour and mean diameter of Ag@SiO2 nanoparticles caused by the introduction of the gold salt were found dependent on its concentration. Upon increasing (KAuCl4) the diameter of nanoparticles …

AbsorbanceColloidMaterials scienceAlloyAnalytical chemistryengineeringNanoparticleDLVO theoryInteraction energyengineering.materialSurface plasmon resonanceSilver nanoparticleNanoscience and Nanotechnology
researchProduct

Spectrophotometric determination of ethiofencarb in waters by reaction with p-aminophenol

1993

An automatized procedure has been developed for the spectrophotometric determination of ethiofencarb in water by reaction with p-aminophenol after alkaline hydrolysis to obtain the corresponding phenol sulphone. The hydrolyzed samples are continuously introduced into different manifolds at the same time as 300 mg/l p-aminophenol, 0.004 mol/l KIO4 and 0.04 mol/l NaOH solutions. The absorbance is measured at 638 nm after a reaction time of 6 min in stop flow. This absorbance band corresponds to the indo dye obtained from the reaction between the phenol sulphone of ethiofencarb and the quinoneimine form of the p-aminophenol and it permits a matrix-free spectrophotometric determination of ethio…

AbsorbanceDetection limitHydrolysischemistry.chemical_compoundChemistryP-AminophenolEthiofencarbAnalytical chemistryPhenolAlkaline hydrolysis (body disposal)BiochemistryChemical reactionNuclear chemistryFresenius' Journal of Analytical Chemistry
researchProduct

Creatinine determination in urine samples by batchwise kinetic procedure and flow injection analysis using the Jaffé reaction: chemometric study

2001

The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval w…

AbsorbanceFlow injection analysisCreatininechemistry.chemical_compoundChromatographychemistryCalibration curveStandard additionCalibrationAnalytical chemistryUrineQuantitative analysis (chemistry)Analytical ChemistryTalanta
researchProduct

The linear absorbances method adapted to systems with two interfering compounds

1993

The paper exposes the theoretical and experimental study performed with the purpose to extend the application of the Linear Absorbances Method to more complex systems, which present two spectral interferences. The curves of collinearity are developed and a theoretical study of them is carried out. The theoretical equations developed are experimentally tested and the influence of the variables involved in the Linear Absorbance Method is studied, too. It is concluded that the use of couples of collinear wavelengths of the interferents allows to obtain the concentration of a compound in the presence of two interfering substances.

AbsorbanceMaterials scienceComplex systemLinearityCollinearityBiological systemBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Utilization of impedance spectroscopy to investigate the self-assembly behavior of amphiphiles soluble in supercritical carbon dioxide: Preliminary r…

2007

Abstract A mixture of CO 2 , water, methyl orange (MO) and Dynol 604 surfactant was analyzed at 309 K and 20 MPa simultaneously by impedance and UV–vis spectroscopy. A plot of the static dielectric constant as a function of the surfactant concentration was obtained using a suitable equivalent circuit to elaborate impedance data. Experimental points can be fitted by two different straight lines whose intersection occurs at about 0.13% (w/w) concentration of Dynol. When the surfactant concentration crossed the aforementioned value, a peak was detectable in the UV–vis spectrum at a wavelength range corresponding to the absorption of MO; absorbance of the peak increased with the surfactant conc…

AbsorbanceSupercritical carbon dioxidePulmonary surfactantChemistryGeneral Chemical EngineeringCritical micelle concentrationAnalytical chemistryMicroemulsionPhysical and Theoretical ChemistryCondensed Matter PhysicsSpectroscopySupercritical fluidDielectric spectroscopyThe Journal of Supercritical Fluids
researchProduct

A kinetic-catalytic method for iodide based on the simultaneous addition of inhibitor and substrate

1987

Abstract A kinetic-catalytic method of analysis, based on the addition of a mixture of inhibitor and substrate, at a constant rate, over the catalyst in the presence of the other component of the indicator reaction is studied. The method is applied to the determination of iodide using the Ce(IV)As(III) catalytic reaction and Hg(II) as inhibitor. Under suitable experimental conditions the absorbance of the unconsumed Ce(IV) is inversely proportional to the initial iodide concentration.

Absorbancechemistry.chemical_classificationChemistryInorganic chemistryIodideSubstrate (chemistry)Reaction inhibitorKinetic energyChemical reactionSpectroscopyCatalytic methodAnalytical ChemistryCatalysisMicrochemical Journal
researchProduct

Residual water and electrical properties of polyaniline

1994

Summary form only given. The work aims to study the mechanism of interaction between water molecules and polyaniline (PANI) backbone as an important constituent of acid-base transformations ensuring good conductive properties of PANI. Experiments have been made using chemically synthesized emeraldine base subjected to different chemical treatments and aging procedures. Thermogravimetric measurement have shown that water content in polymeric matrices may amount up to 20-25 wt.% with two distinguished reversible absorbance states of water molecules. Weakly bond water (3-5 kcal/mol) is incorporated into PANI from ambient atmosphere and could be eliminated by drying at room temperature in vacuu…

Absorbancechemistry.chemical_classificationThermogravimetric analysischemistry.chemical_compoundChemical engineeringChemistryPolyanilineDopingMoleculeOrganic chemistryPolymerConductivityWater contentInternational Conference on Science and Technology of Synthetic Metals
researchProduct

FTIR quantitative analysis of calcium carbonate (calcite) and silica (quartz) mixtures using the constant ratio method. Application to geological sam…

2002

A methodology for quantifying calcium carbonate (875 and 712 cm(-1)) and silica (798 and 779 cm(-1)) by FTIR spectroscopy applying the constant ratio method is proposed. The studied method is applied for quantitative analysis of calcite and quartz in geological samples. The suggested method uses potassium ferricyanide (2115 cm(-1)) as standard and samples are prepared as potassium bromide pellets, with statistically satisfactory results (relative standard deviation less than 5%). The influence of particle size (pulverised samples) on the accuracy of the results found by FTIR spectroscopy applying the constant ratio method has been studied. The granulometric study suggests that the homogenei…

Absorbancechemistry.chemical_compoundCalcium carbonatechemistryPotassium bromidePelletsAnalytical chemistryCarbonateInfrared spectroscopyParticle sizeFourier transform infrared spectroscopyAnalytical ChemistryTalanta
researchProduct