Search results for "Accelerator"
showing 10 items of 1507 documents
Laser ion source tests at the HRIBF on stable Sn, Ge and Ni isotopes
2006
Abstract As one step in the ion source development for the Rare Isotope Accelerator, a hot-cavity laser ion source using an all-solid-state titanium–sapphire laser system has been tested at the Holifield Radioactive Ion Beam Facility. Resonance ionization of stable isotopes of Sn, Ge and Ni has been studied in a Ta hot cavity. Efficient three step resonant ionization schemes applying frequency tripling for the first excitation step and using auto-ionizing or atomic Rydberg states in the ionizing step have been identified for all three elements, resulting in laser ion beams of typically around 100 nA. By saturating most of the optical excitation steps involved, ionization efficiencies of 22%…
Laser photodetachment of radioactive $^{128}$I$^−$
2017
International audience; The first experimental investigation of the electron affinity (EA) of a radioactive isotope has been conducted at the CERN-ISOLDE radioactive ion beam facility. The EA of the radioactive iodine isotope (128)I (t (1/2) = 25 min) was determined to be 3.059 052(38) eV. The experiment was conducted using the newly developed Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) apparatus, connected to a CERN-ISOLDE experimental beamline. (128)I was produced in fission induced by 1.4 GeV protons striking a thorium/tantalum foil target and then extracted as singly charged negative ions at a beam energy of 20 keV. Laser photodetachment of th…
Application and development of ion-source technology for radiation-effects testing of electronics
2017
Abstract Studies of heavy-ion induced single event effect (SEE) on space electronics are necessary to verify the operation of the components in the harsh radiation environment. These studies are conducted by using high-energy heavy-ion beams to simulate the radiation effects in space. The ion beams are accelerated as so-called ion cocktails, containing several ion beam species with similar mass-to-charge ratio, covering a wide range of linear energy transfer (LET) values also present in space. The use of cocktails enables fast switching between beam species during testing. Production of these high-energy ion cocktails poses challenging requirements to the ion sources because in most laborat…
The laser ion source and trap (LIST) – A highly selective ion source
2008
A combined structure consisting of a laser ion source and a linear Paul trap (LIST) has been designed to produce radioactive ion beams of high purity and optimal temporal and spacial brilliance at on-line isotope separator (ISOL) facilities. The functionality of the LIST was experimentally demonstrated in off-line tests using the RISIKO off-line mass separator together with an all solid state Ti:sapphire laser system at the University of Mainz. Two different ion trap designs were tested extracting the performance of these devices regarding ionization efficiency and selectivity as well as time structure and transverse emittance of the produced ion beam. The results of these measurements are …
Optical spectroscopy and performance tests with a solid state laser ion source at HRIBF
2008
An ISOLDE-type hot-cavity laser ion source based on high-repetition-rate Ti:Sapphire lasers has been set up at the Holifield radioactive ion beam facility. To assess the feasibility of the all-solid-state laser system for applications at advanced radioactive ion beam facilities, spectroscopy and performance tests have been conducted with this source. The results of recent studies on excitation schemes, source efficiency, beam emittance and ion time structure are presented.
Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)
2016
Abstract We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicat…
Resonant laser ionization mass spectrometry: An alternative to AMS?
2000
Resonant laser ionization mass spectrometry (RIMS) has developed into a versatile experimental method particularly concerning applications for highly selective ultratrace analysis. Apart from providing nearly complete isobaric suppression and high overall efficiency, the possibility for combining optical isotopic selectivity with that of the mass spectrometer leads to remarkable specifications. The widespread analytical potential and applicability of different techniques based on resonant laser ionization is demonstrated in investigations on stable and radioactive ultratrace isotopes with the focus on applications which require high selectivity, concerning, e.g., the noble gas isotopes 81,8…
Resonance ionization mass spectroscopy for nuclear research and trace analysis
1987
Resonance ionization mass spectroscopy (RIMS) has been applied, firstly, to a study of the nuclear properties of short-lived Au isotopes at the on-line isotope separator ISOLDE at CERN and, secondly, to a trace-analysis experiment of Pu.
Atomic spectroscopy studies of short-lived isotopes and nuclear isomer separation with the ISOLDE RILIS
2002
The Resonance Ionization Laser Ion Source (RILIS) at the ISOLDE on-line isotope separator is based on the selective excitation of atomic transitions by tunable laser radiation. Ion beams of isotopes of 20 elements have been produced using the RILIS setup. Together with the mass separator and a particle detection system it represents a tool for high-sensitive laser spectroscopy of short-lived isotopes. By applying narrow-bandwidth lasers for the RILIS one can study isotope shifts (IS) and hyperfine structure (HFS) of atomic optical transitions. Such measurements are capable of providing data on nuclear charge radii, spins and magnetic moments of exotic nuclides far from stability. Although t…
Optical polarization of neutron-rich sodium isotopes and β-NMR measurements of quadrupole moments
1996
The nuclear quadrupole moments of neutron-rich sodium isotopes are being investigated with the help of in-beam polarization by optical pumping in combination with $\beta$-NMR techniques. First measurements have yielded the quadrupole splittings of NMR signals in the lattice of LiNbO$_{3}$ for the isotopes $^{26}$Na, $^{27}$Na and $^{28}$Na. Interaction constants and ratios of the electric quadrupole moments are derived. In view of future experiments, $\beta$-decay asymmetries for the sequence of isotopes up to the $N$=20 neutron shell closure, $^{26-31}$Na, have been measured.