Relationship between muscular extensibility, strength and stability and the transmission of impacts during fatigued running
2020
The aim was to analyse the relationship between isokinetic strength, dynamic stability, muscular extensibility and impacts transmission during fatigued running. Low- and high-frequency impacts related to body movements and the severity of impacts, respectively were assessed in 17 male recreational runners, before and after a treadmill running fatigue protocol, using a triaxial accelerometry system. High-frequency impacts in the tibia were negatively correlated to the knee angle at which the quadriceps peak torque was reached (p = 0.014), and also to the extensibility of the hamstrings and soleus (p = 0.001 and p = 0.023, respectively). The increases of high-frequency impacts in tibia caused…
Effects of Kinesiotape® taping on plantar pressure and impact acceleration during walking
2014
Summary Objectives The aim of this study was to analyse the plantar pressure pattern, contact time, stride rate and impact acceleration in the shank during walking with and without Kinesio Tape (KT®) placed on two muscle groups: peroneus and triceps surae. Methods Among the subjects, 29 (12 men, 17 women) participated in the study. KT® was placed on the triceps surae and peroneus and participants walked at two different speeds (V1: 0.73 m/s; V2: 1.30 m/s) with and without KT®. The pedobarographic system Biofoot IBV® 6.0 was used to analyse plantar pressure (mean peak pressure [kPa]) in 5 foot areas and the kinematic variables of the study (contact time [s]; stride rate [steps/second]). One …
Embedding Monitoring Systems for Cured-In-Place Pipes
2017
This paper proposes a non-intrusive electrical measurement system for monitoring some relevant parameters in pipeline systems. Temperature and flow-rate are monitored, using MEMS sensors. The flow-rate is evaluated by measuring pipe vibration, with a 3 axis accelerometer, induced by turbulence when fluid flows within the tube. The sensors are embedded, during the curing process of the cured-in-place pipes, in the pipes wall making the system suitable to be installed in renewed or new pipeline. The first experimental results show that it may be possible to obtain, at low-cost, a fully monitored distribution network.
Characterization of MEMS accelerometer self-noise by means of PSD and Allan Variance analysis
2017
In this paper, we have studied the sources of error of a low-cost 3-axis MEMS accelerometer by means of Power Spectral Density and Allan Variance techniques. These techniques were applied to the signals acquired from ten identical devices to characterize the variability of the sensor produced by the same manufacturer. Our analysis showed as identically produced accelerometer have somehow variable behavior in particular at low frequency. It is therefore of paramount importance before their use in Inertial Navigation or Earthquakes Monitoring System, a complete characterization of each single sensors.
Urban MEMS based seismic network for post-earthquakes rapid disaster assessment
2014
Abstract. In this paper, we introduce a project for the realization of the first European real-time urban seismic network based on Micro Electro-Mechanical Systems (MEMS) technology. MEMS accelerometers are a highly enabling technology, and nowadays, the sensitivity and the dynamic range of these sensors are such as to allow the recording of earthquakes of moderate magnitude even at a distance of several tens of kilometers. Moreover, thanks to their low cost and smaller size, MEMS accelerometers can be easily installed in urban areas in order to achieve an urban seismic network constituted by high density of observation points. The network is being implemented in the Acireale Municipality (…
Evaluation of a Completely Robotized Neurosurgical Operating Microscope
2012
BACKGROUND Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. OBJECTIVE We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. METHODS A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted…
Personality traits and physical functioning : a cross-sectional multimethod facet-level analysis
2020
Background This study aimed to investigate whether personality traits and their facets are associated with a multi-methods assessment of physical activity and walking performance and whether they explain the discrepancy between self-reported and accelerometer-assessed physical activity. Methods The participants were community-dwelling, 70–85-year-old men and women from Finland (n = 239) who were part of a clinical trial. Personality traits and their facets were measured using the 240-item NEO Personality Inventory-3. Physical activity was assessed using questions about frequency, intensity and duration of exercise (self-reported metabolic equivalent minutes (MET)) and by tri-axial accelerom…
Validity and reliability of a 3-axis accelerometer for measuring weightlifting movements
2016
The purpose of the current study was to assess the validity and reliability of measures obtained by a 3-axis commercial accelerometer during weightlifting movements in comparison with kinematic data derived from the 3D videography. Kinematic data from 3D videography were obtained from 11 track & field throwers performing 3 trials each one at different loads in power snatch, power clean and jerk from the rack. The results showed that the accelerometer measures were highly correlated with derived acceleration data from 3D videography data in the vertical plane (Z axis) taking up to the pull phase (including first pull, transition and second pull) for power snatch and power clean and up t…
Experiences from a wearable-mobile acquisition system for ambulatory assessment of diet and activity
2017
Public health trends are currently monitored and diagnosed based on large studies that often rely on pen-and-paper data methods that tend to require a large collection campaign. With the pervasiveness of smart-phones and -watches throughout the general population, we argue in this paper that such devices and their built-in sensors can be used to capture such data more accurately with less of an effort. We present a system that targets a pan-European and harmonised architecture, using smartphones and wrist-worn activity loggers to enable the collection of data to estimate sedentary behavior and physical activity, plus the consumption of sugar-sweetened beverages. We report on a unified pilot…
The multivariate physical activity signature associated with metabolic health in children and youth: An International Children's Accelerometry Databa…
2020
There is solid evidence for an association between physical activity and metabolic health outcomes in children and youth, but for methodological reasons most studies describe the intensity spectrum using only a few summary measures. We aimed to determine the multivariate physical activity intensity signature associated with metabolic health in a large and diverse sample of children and youth, by investigating the association pattern for the entire physical intensity spectrum. We used pooled data from 11 studies and 11,853 participants aged 5.8–18.4 years included in the International Children's Accelerometry Database. We derived 14 accelerometry-derived (ActiGraph) physical activity variabl…