Search results for "Accuracy"
showing 10 items of 277 documents
Paediatric Sleep Questionnaire for Obstructive Sleep Apnoea Syndrome Screening: Is Sleep Quality Worthy of Note?
2021
Obstructive sleep apnoea syndrome (OSAS) is the most severe condition on the spectrum of sleep-related breathing disorders (SRBDs). The Paediatric Sleep Questionnaire (PSQ) is one of the most used and validated screening tools, but it lacks the comprehensive assessment of some determinants of OSAS, specifically anamnestic assessment and sleep quality. This study aims to assess the accuracy of some specific items added to the original PSQ, particularly related to the patient’s anamnestic history and to the quality of sleep, for the screening of OSAS in a paediatric population living in Sicily (Italy). Fifteen specific items, divided into “anamnestic” and “related to sleep quality” were added…
La fatigue mentale : marqueurs électrophysiologiques et stratégies de compensation
2021
Mental fatigue is a common phenomenon in modern society, causing an alteration in both cognitive and physical performances. It can lead to an increased risk of accidents, a drop in productivity, and certain disorders such as depression. The objective of this thesis work was to study this phenomenon of mental fatigue by investigating more specifically its electrophysiological markers, and to find compensatory strategies to limit and/or avoid its deleterious effects.The first study identified brain activity modulations during a prolonged modified Stroop task. An increase in theta and alpha waves, as well as a decrease in N100 and P300 amplitude reflecting a decrease in attention were observed…
Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review
2023
Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated into wrist-worn commercial products which presents significant advantages in terms of cost and dimensions. PPG-based devices, despite their ability to detect multiple cardiovascular parameters, are affected by several influencing conditions that depend both on technological or environmental variables, and on intra- and inter-subject variability that influences the whole measurement chain and reliability, hindering an objective characterization of PPG devices. Plus, the lack of standardization for data collect…
Precision mass measurements of antiprotons in a Penning trap
1992
Utilizing electron cooling, the TRAP collaboration has lowered the energy at which antiprotons can be stored and studied by more than 10 orders of magnitude, starting with 6 MeV particles from LEAR. We have held cryogenic antiprotons a few degrees above absolute zero for two months and the storage lifetime so established, more than 3.4 months is the longest directly measured limit for antiprotons. Measuring their cyclotron frequencies in a precision cylindrical Penning trap, we have shown that the inertial masses of the antiprotons and protons are the same to a fractional accuracy of 4 parts in 108, a 1000-fold improvement over the previous comparisons. This is the most stringent test of CP…
Feasibility of Coulomb blockade thermometry in metrology
2000
Abstract Coulomb blockade thermometer (CBT) is a simple, magnetic-field-independent primary thermometer for everyday use at cryogenic temperatures. Its properties are well understood by now. The absolute accuracy at present is about ±0.5%. Recently, we have started studying the possibility of using CBT in metrological applications. We have especially in mind the future extension of the international temperature scale below 0.65 K, which is the lower end of ITS-90. Experiments with arrays containing more than 100 tunnel junctions in series are in progress in order to decrease the effects of electromagnetic environment and of co-tunnelling even below the present level.
Reactor antineutrino detection in Double Chooz experiment: Techniques for background reduction
2014
Abstract A crucial task for the Double Chooz reactor antineutrino experiment is the thorough study of the different backgrounds in the detector. Newly developed background reduction techniques minimize the impact of the backgrounds on our sensitivity. Moreover, only a precision and accuracy measurement of the residual background would allow to measure the mixing angle θ 13 with high precision. Neutrino coincidence signals are imitated by signals produced in several others physics processes: accidental coincidences of single events (accidental background), as well as correlated events induced by cosmic muons, including stopping muons, fast neutrons and spallation isotopes Li 9 /He 8 . The Do…
One and two dimensional tunnel junction arrays in weak Coulomb blockade regime-absolute accuracy in thermometry
1999
We have investigated one and two dimensional (1D and 2D) arrays of tunnel junctions in partial Coulomb blockade regime. The absolute accuracy of the Coulomb blockade thermometer is influenced by the external impedance of the array, which is not the same in the different topologies of 1D and 2D arrays. We demonstrate, both by experiment and by theoretical calculations in simple geometries, that the 1D structures are better in this respect. Yet in both 1D and 2D, the influence of the environment can be made arbitrarily small by making the array sufficiently large.
Investigation of an entropic stabilizer for the lattice-Boltzmann method
2015
The lattice-Boltzmann (LB) method is commonly used for the simulation of fluid flows at the hydrodynamic level of description. Due to its kinetic theory origins, the standard LB schemes carry more degrees of freedom than strictly needed, e.g., for the approximation of solutions to the Navier-stokes equation. In particular, there is freedom in the details of the so-called collision operator. This aspect was recently utilized when an entropic stabilizer, based on the principle of maximizing local entropy, was proposed for the LB method [I. V. Karlin, F. Bosch, and S. S. Chikatamarla, ¨ Phys. Rev. E 90, 031302(R) (2014)]. The proposed stabilizer can be considered as an add-on or extension to b…
Optical Characterization Method for Tilted or Decentered Intraocular Lenses
2016
Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…
Data quality oriented procedure, for detailed mapping of heavy metals in urban topsoil as an approach to human health risk assessment
2021
Abstract Urban soils' health is important to the community because of the soils' potential use for recreational activities. A data quality-oriented approach to sampling design is proposed for performing soil representative surveys that gives support to defensible and statistically-based decisions. Krowoderski park in Cracow (Poland) was selected as a study case to investigate heavy metals (HMs) accumulation and to assess human risk exposure according to simulated scenarios. Statistical power was computed for optimizing the number of samples to compare HMs concentration against legal upper tolerance levels (LUTL). The samples' location was iteratively designed as random spatial distribution …