Adhesive joining of Aluminum AA6082: the effect of resin and surface treatment
2009
Abstract In this work the effects of both the substrate surface condition and the adhesive properties on single-lap aluminium joint resistance were analysed. The aluminium sheets were mechanically treated with two abrasive surfaces evaluating the induced roughness; four different resins were used in adhesion tests. Moreover, wettability tests were performed in order to evaluate the effect of the above-mentioned parameters on the substrate/adhesive interaction. A design of experiments was defined in order to quantify the effect of the considered factors and their correlation.
Effects of anodizing surface treatment on the mechanical strength of aluminum alloy 5083 to fibre reinforced composites adhesive joints
2021
Abstract In this study, the anodizing process based on the use of tartaric sulfuric acid solution (TSA) was carried out on metal substrate to evaluate for the first time its effect on the adhesion strength and corrosion resistance of aluminium alloy (i.e., AA5083) to fibre (i.e., basalt or glass) reinforced composite adhesive joints for nautical applications. Furthermore, some TSA anodized samples were soaked in a NaOH solution to investigate the influence of this post-immersion step on the joint performances. With the aim to improve the fibre-matrix adhesion in the composite substrate thus further increasing the overall mechanical response of the joint, glass and basalt fibres were treated…
Microhardness of different resin cement shades inside the root canal
2012
Objectives: To compare microhardness along the root canal post space of two resin cements in different shades and a dual-cure resin core material. Study Design: Root canals of 21 bovine incisors were prepared for post space. Translucent posts (X•Post, Dentsply DeTrey) were luted using one the following resin luting agent: Calibra (Dentsply DeTrey) in Translucent, Medium and Opaque shades, RelyX Unicem (3M ESPE) in Translucent, A2 and A3 shades and the dual-cure resin core material Core•X flow. All materials were applied according to manufacturers’ instructions and were all photopolymerized (Bluephase LED unit, Ivoclar Vivadent, 40s). After 24 hours, roots were transversally cut into 9 slice…
Comparative evaluation of orthodontic bracket base shapes on shear bond strength and adhesive remnant index : an in vitro study
2017
BACKGROUND The objective of this study was to evaluate the effect of orthodontic bracket base shape on shear bond strength and adhesive remnant index. MATERIAL AND METHODS In this in vitro study using 140 bovine incisors, shear bond strength (SBS) of brackets with different base shapes (rectangle, flower, round, heart, diamond, star, and football) were measured with an Instron testing machine and tested until bond failure. Adhesive Remnant Index (ARI) scoring was evaluated after debonding to evaluate the location of bond failure. Descriptive and one-way ANOVA post-hoc Tukey statistical analyses were performed with a statistical significance set at p≤0.05. RESULTS Statistically significant d…
The impact of different surface treatments on the shear bond strength of orthodontic metal brackets applied to different CAD/CAM composites
2020
Background To investigate the shear bond strength (SBS) of orthodontic metal brackets applied to different CAD/CAM composites treated with different surface treatments. Material and Methods Specimens of two CAD/CAM composites were obtained of Lava Ultimate (LU; n=60) and Brilliant Crios (BC; n=60) which were randomly separated into six subgroups (n=10) according to the surface treatment: control (CTL); sandblasting (SB); sandblasting and silane (SBSL); hydrofluoric acid (HF); hydrofluoric acid and silane (HFSL); and Monobond Etch&Prime (MEP). The mandibular central incisor metal brackets were bonded with a light-cure adhesive. The SBS data were analyzed using the two-way analysis of varianc…
Magnitude and distribution of stresses in composite resin and sound dentine interface with mechanical retentions
2014
Background: Adhesive systems are constantly subjected to mechanical and chemical stresses that negatively impact the integrity and durability of the dentine-adhesive interface. Despite the lack of evidence to support or reject the clinical indication for mechanical retention, the potential further contribution of these preparations to the behavior of the composite resin-sound dentine bond has been rarely addressed. The authors evaluated by finite element analysis the effect of mechanical retention on the magnitude and distribution of stresses in a composite resin-sound dentin bonding interface when subjected to tensile and shear forces. Material and Methods: A three-dimensional model was cr…
Fractographic study of the behavior of different ceramic veneers on full coverage crowns in relation to supporting core materials
2013
Objectives: To observe porcelain veneer behavior of zirconia and metal-ceramic full coverage crowns when subjected to compression testing, comparing zirconia cores to metal cores. Study Design: The porcelain fracture surfaces of 120 full coverage crowns (60 with a metal core and 60 with a zirconia core) subjected to static load (compression) testing were analyzed. Image analysis was performed using macroscopic processing with 8x and 12x enlargement. Five samples from each group were prepared and underwent scanning electron microscope (SEM) analysis in order to make a fractographic study of fracture propagation in the contact area and composition analysis in the most significant areas of the…
Push-out bond strength of quartz fiber posts to root canal dentin using total-etch and self-adhesive resin cements
2011
Objectives: Several adhesive systems are available for cementation of fibre posts into the root canal. The aim of the present study was to investigate the push-out bond strengths of quartz fibre posts to root dentin with the use of different total-etch and self-adhesive resin cements. Study Design: Ninety single-rooted human premolars were endodontically treated and standardized post-spaces were prepared. Fibre posts were cemented with different luting agents: total-etch (Nexus NX3, Duo-Link, and RelyX ARC) and self-adhesive resin cements (Maxcem Elite, BisCem, and RelyX Unicem). Three post/dentin sections (coronal, middle and apical) were obtained from each specimen, and push-out bond stre…
Fracture resistance of endodontically treated teeth with different direct corono-radicular restoration methods.
2016
BACKGROUND Endodontically treated teeth are widely considered to be more susceptible to fracture than vital teeth. Obturation procedures and post placement have been a main cause of vertical root fracture. MATERIAL AND METHODS Forty-eight human premolars with standardized weakened roots were endodontically treated and allocated to four experimental groups (n=12). After root canal treatment, in group 1, fiber posts #1 were cemented in root canals using Estelite Core Quick, and the crowns were restored with resin composite. For group 2 and 3, the roots and crowns were restored using a light-cured and self-cured adhesive and resin composites respectively. In group 4, it was used the Panavia F …
Interaction effect of Nd:YAG laser and universal adhesive system for dentin sealing
2020
Made available in DSpace on 2021-06-25T10:46:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: To evaluate the influence of the association of the universal adhesive system to different energy densities of the Nd:YAG laser on the hydraulic conductance of dentin. Material and Methods: Fifty bovine dentin discs were made. The samples were stratified into four groups (n = 10) according to the treatment performed; SBU- Adper Single Bond Universal (3M ESPE), SBU_60 - SBU associated with the Nd:YAG laser (60mJ, 10Hz, 0.6W - 47.77 J / cm²), SBU_80 - SBU associated with the Nd:YAG laser (80mJ, 10Hz, 0.8 W - 63.69 J / cm2) and C – dentin without treatment (smear layer). Hyd…