Search results for "Aging"
showing 10 items of 10496 documents
Radiation protection in non-ionizing and ionizing body composition assessment procedures
2020
Body composition assessment (BCA) represents a valid instrument to evaluate nutritional status through the quantification of lean and fat tissue, in healthy subjects and sick patients. According to the clinical indication, body composition (BC) can be assessed by different modalities. To better analyze radiation risks for patients involved, BCA procedures can be divided into two main groups: the first based on the use of ionizing radiation (IR), involving dual energy X-ray absorptiometry (DXA) and computed tomography (CT), and others based on non-ionizing radiation (NIR) [magnetic resonance imaging (MRI)]. Ultrasound (US) techniques using mechanical waves represent a separate group. The pur…
Adaptive Bias Field Correction: Application on Abdominal MR Images
2017
Segmentation of medical images is one of the most important phases for disease diagnosis. Accuracy, robustness and stability of the results obtained by image segmentation is a major concern. Many segmentation methods rely on absolute values of intensity level, which are affected by a bias term due to in-homogeneous field in magnetic resonance images. The main objective of this paper is two folded: (1) To show efficiency of an energy minimization based approach, which uses intrinsic component optimization, on abdominal magnetic resonance images. (2) To propose an adaptive method to stop the optimization automatically. The proposed method can control the value of the energy functional and sto…
Virtual reality system for planning minimally invasive neurosurgery
2008
Object The authors report on their experience with a 3D virtual reality system for planning minimally invasive neurosurgical procedures. Methods Between October 2002 and April 2006, the authors used the Dextroscope (Volume Interactions, Ltd.) to plan neurosurgical procedures in 106 patients, including 100 with intracranial and 6 with spinal lesions. The planning was performed 1 to 3 days preoperatively, and in 12 cases, 3D prints of the planning procedure were taken into the operating room. A questionnaire was completed by the neurosurgeon after the planning procedure. Results After a short period of acclimatization, the system proved easy to operate and is currently used routinely for pre…
The Small Size and Superficial Location Suggest That Laparoscopic Partial Nephrectomy Is the First Choice for the Treatment of Juxtaglomerular Cell T…
2021
BackgroundJuxtaglomerular cell tumor (JGCT) is a very rare disease, and surgical resection is the only possible way to cure this tumor. Open nephrectomy and partial nephrectomy have been reported to manage JGCTs with excellent results in the previous reviews. Laparoscopic surgery has been popularized in recent years, while critical issues associated with laparoscopic surgical management have been seldom reported. We summarized the JGCTs in our center to discover the optimal surgical management and its anatomic foundation.MethodsIn this retrospective study, we enrolled a total of 14 JGCT patients. All patients received surgeries and were followed up for up to 11 years. We mainly summarized t…
Autostereoscopic Three-Dimensional Neuronavigation to the Sella: Technical Note.
2017
Background A drawback of conventional neuronavigation is the necessity of focusing on two-dimensional images in 3 planes at the same time to determine one's position in the operating field. A solution would be to merge the images into a single three-dimensional (3D) image that mirrors the actual anatomy. The introduction of holographic glassless 3D monitors paved the way to 3D navigation. We present our experience with 3D neuronavigation as exemplified by navigation to and within the sella. Methods Operative planning was conducted with a navigation system using cranial computed tomography and magnetic resonance imaging. The image data sets were processed by the prototype Clariti 3D system t…
Incident colorectal cancer in Lynch syndrome is usually not preceded by compromised quality of colonoscopy
2019
AbstractBackground: Lifetime incidence of colorectal cancer (CRC) especially in carriers of MLH1 and MSH2 pathogenic germline variants in mismatch repair genes is high despite ongoing colonoscopy s...
Contribution of thallium-201-SPECT to the grading of tumorous alterations of the brain
1992
Single photon emission computed tomography (SPECT) with thallium-201-chloride (201Tl) was used in 22 patients to assess the grade of malignancy of brain tumors. Low- and high-grade malignant gliomas could be well differentiated by calculating the Grade Index (GI), i.e., 201Tl uptake in the tumor area relative to a contralateral brain region. Low-grade gliomas (WHO-grade I-II) usually showed a GI of1.5. Tumors classified histologically as high-grade malignant (WHO-grade III-IV) had GI values greater than 1.42 and a mean value of 1.89. Until labelled amino-acid tracers for gamma-cameras become commercially available, thallium-201 brain-SPECT can provide an independent and complementary method…
CT and MR Imaging Evaluation of Hepatic Adenoma
2006
Hepatic adenoma is a rare benign epithelial tumor that is usually encountered in young women who use oral contraceptives. It is clinically significant because of the risk of hemorrhage and of its low-grade malignancy potential. Adenomas usually are mildly hypervascular at contrast-enhanced CT and MR imaging, and heterogeneous due to the presence of hemorrhage, necrosis, calcifications and fat. The objective of our study was to illustrate the CT and MR imaging findings of hepatic adenoma.
Perfusion MRI in normal and abnormal pituitary gland. A preliminary study.
1997
Perfusion MRI (magnetic resonance imaging) of the pituitary gland was performed in 20 healthy volunteers and 63 patients with various lesions involving the pituitary gland. All patients underwent sequential contrast-enhanced MRI using spoiled gradient recalled sequences with high temporal resolution (7 seconds). Four pituitary areas (pituitary stalk, posterior lobe, postero-superior, and antero-inferior adenohypophysis) were tested with a selected region of interest. Maximal contrast percentual variation was calculated. The timing of enhancement in normal patients matched perfectly with normal pituitary vascularization. Abnormal timing in pathological condition was investigated.
Development and validation of the SIMPLE endoscopic classification of diminutive and small colorectal polyps
2018
Abstract Background Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. Methods In phase 1, a new simplified endoscopic classification for polyps – Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) – was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp hi…