Search results for "Algorithm"
showing 10 items of 4887 documents
Model-Based Dose Calculation Algorithms for Brachytherapy Dosimetry
2019
The purpose of this study was to review the limitations of dose calculation formalisms for photon-emitting brachytherapy sources based on the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) report and to provide recommendations to transition to model-based dose calculation algorithms. Additionally, an overview of these algorithms and approaches is presented. The influence of tissue and seed/applicator heterogeneities on brachytherapy dose distributions for breast, gynecologic, head and neck, rectum, and prostate cancers as well as eye plaques and electronic brachytherapy treatments were investigated by comparing dose calculations based on the TG-43 formalism …
Is BRCA1-5083del19, identified in breast cancer patients of Sicilian origin, a Calabrian founder mutation?
2007
Various studies have been published in Italy regarding the different BRCA1 mutations, but only the BRCA1-5083del19 mutation is recurrent and specific to individuals of Italian descent with a founder effect on the Calabrian population. In our previous study, BRCA1-5083del19 mutation carriers were found in four index cases of 106 Sicilian patients selected for familial and/or hereditary breast/ovarian cancers. The high frequency rate of this mutation identified in the Sicilian population led us to perform haplotype analysis in all family carriers. Five highly polymorphic microsatellite markers were used (D17S1320, D17S932, D17S1323, D17S1326, D17S1325) to establish whether or not all these fa…
Clinical predictors and algorithm for the genetic diagnosis of pheochromocytoma patients.
2009
Abstract Purpose: Six pheochromocytoma susceptibility genes causing distinct syndromes have been identified; approximately one of three of all pheochromocytoma patients carry a predisposing germline mutation. When four major genes (VHL, RET, SDHB, SDHD) are analyzed in a clinical laboratory, costs are ∼$3,400 per patient. The aim of the study is to systematically obtain a robust algorithm to identify who should be genetically tested, and to determine the order in which genes should be tested. Experimental Design: DNA from 989 apparently nonsyndromic patients were scanned for germline mutations in the genes VHL, RET, SDHB, SDHC, and SDHD. Clinical parameters were analyzed as potential predic…
MPL mutation effect on JAK2 46/1 haplotype frequency in JAK2V617F-negative myeloproliferative neoplasms
2010
MPL mutation effect on JAK2 46/1 haplotype frequency in JAK2 V617F-negative myeloproliferative neoplasms
Genome-wide association scan of quantitative traits for attention deficit hyperactivity disorder identifies novel associations and confirms candidate…
2008
Contains fulltext : 70192.pdf (Publisher’s version ) (Closed access) Attention deficit hyperactivity disorder (ADHD) is a complex condition with environmental and genetic etiologies. Up to this point, research has identified genetic associations with candidate genes from known biological pathways. In order to identify novel ADHD susceptibility genes, 600,000 SNPs were genotyped in 958 ADHD proband-parent trios. After applying data cleaning procedures we examined 429,981 autosomal SNPs in 909 family trios. We generated six quantitative phenotypes from 18 ADHD symptoms to be used in genome-wide association analyses. With the PBAT screening algorithm, we identified 2 SNPs, rs6565113 and rs5526…
Troponin I Assay for Identification of a Significant Coronary Stenosis in Patients with Suspected Acute Myocardial Infarction and Wide QRS Complex
2016
Background Common ECG criteria such as ST-segment changes are of limited value in patients with suspected acute myocardial infarction (AMI) and bundle branch block or wide QRS complex. A large proportion of these patients do not suffer from an AMI, whereas those with ST-elevation myocardial infarction (STEMI) equivalent AMI benefit from an aggressive treatment. Aim of the present study was to evaluate the diagnostic information of cardiac troponin I (cTnI) in hemodynamically stable patients with wide QRS complex and suspected AMI. Methods In 417 out of 1818 patients presenting consecutively between 01/2007 and 12/2008 in a prospective multicenter observational study with suspected AMI a pro…
Unique pharmacology of KAR-2, a potential anti-cancer agent: absorption modelling and selective mitotic spindle targeting.
2008
Abstract Bis-indols are a large group of the anti-cancer agents, which effectively arrest the uncontrolled division of the cancerous cells. Their use in clinical chemotherapy is still limited because of: (i) the non-specific targeting of the mitotic cells; (ii) low bioavailability of the drugs. KAR-2 has been identified as a tubulin binding agent which displays significantly lower cytotoxicity but favourable anti-cancer potency than its mother molecule, vinblastine. The objective of this paper, on one hand, was to show that the human intestinal epithelial Caco-2 cells, used for pharmacokinetic studies display distinct sensitivity against KAR-2 and vinblastine due to their distinct targeting…
Usefulness of high-sensitivity troponin T for the evaluation of patients with acute chest pain and no or minimal myocardial damage
2012
Although high-sensitivity troponins allow early diagnosis of acute myocardial infarction, their role for identification of acute coronary syndrome in patients with normal conventional troponin remains unclear.A total of 446 patients presenting to the emergency department with chest pain and normal troponin (common practice assays) in 2 serial samples were included. Both samples were also centrally analyzed for high-sensitivity troponin T (hs-TnT) (Roche Diagnostics, Basel, Switzerland). Detection (3 ng/L) and 99th percentile (≥ 14 ng/L) cutoffs of the maximum hs-TnT levels (hs-TnTmax) were considered. The end points were acute coronary syndrome diagnosis and the composite of in-hospital rev…
Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk
2007
Purpose. Our aim was to evaluate the diagnostic accuracy of 64- slice computed tomography coronary angiography (MSCT-CA) for detecting significant stenosis (≥50% lumen reduction) in a population of patients at low to intermediate risk. Materials and methods. We studied 72 patients (38 men, 34 women, mean age 53.9±8.0 years) with atypical or typical chest pain and stratified in the low- to intermediate risk category. MSCT-CA (Sensation 64 Cardiac, Siemens, Germany) was performed after IV administration of 100 ml of iodinated contrast material (Iomeprol 400 mgI/ml, Bracco, Italy). Two observers, blinded to the results of conventional coronary angiography (CAG), assessed the MSCT-CA scans in c…
Workflow-centred open-source fully automated lung volumetry in chest CT
2019
Aim To develop a robust open-source method for fully automated extraction of total lung capacity (TLC) from computed tomography (CT) images and to demonstrate its integration into the clinical workflow. Materials and methods Using only open-source software, an algorithm was developed based on a region-growing method that does not require manual interaction. Lung volumes calculated from reconstructions with different kernels (TLCCT) were assessed. To validate the algorithm calculations, the results were correlated to TLC measured by pulmonary function testing (TLCPFT) in a subgroup of patients for which this information was available within 3 days of the CT examination. Results A total of 28…