Search results for "Amplifier"

showing 10 items of 239 documents

FPGA based digital lock-in amplifier for fNIRS systems

2018

Lock-In Amplifiers (LIA) represent a powerful technique helping to improve signals detectability when low signal to noise ratios are experienced. Continuous Wave functional Near Infrared Spectroscopy (CW-fNIRS) systems for e-health applications usually suffer of poor detection due to the presence of strong attenuations of the optical recovering path and therefore small signals are severely dipped in a high noise floor. In this work a digital LIA system, implemented on a Zynq® Field Programmable Gate Array (FPGA), has been designed and tested to verify the quality of the developed solution, when applied in fNIRS systems. Experimental results have shown the goodness of the proposed solutions.

010302 applied physicsComputer scienceAmplifier0206 medical engineeringLock-in amplifierDigital lock-in amplifier02 engineering and technology020601 biomedical engineering01 natural sciencesNoise floorSettore ING-INF/01 - ElettronicaSilicon photomultiplier (SiPM)Quality (physics)0103 physical sciencesElectronic engineeringContinuous waveFunctional near-infrared spectroscopyField-programmable gate arrayFpgaFunctional near-infrared spectroscopy
researchProduct

High-Power Multicarrier Generation for RF Breakdown Testing

2017

Testing of satellite components for high RF power breakdown effects, such as multipactor and corona or passive-intermodulation, is a topic of growing interest in the aerospaceindustry. Switching fromthe classical single carrier approach to the more realisticmulticarrier scenario is very challenging from the experimental point of view. Themulticarrier signals, amplifiedby several RF power amplifiers, need to have controlled phase, amplitude, and frequency in each carrier. Fine tuning of the signal generator phases is required in order to compensate the phase drift occurring in the active elements of the test bed. This paper presents an efficient and low-cost technique to generate multicarrie…

010302 applied physicsEngineeringFine-tuningSignal generatorHigh-power RF testingMulticarrierbusiness.industryAmplifierRF power amplifierPhase (waves)Electrical engineering01 natural sciences010305 fluids & plasmasElectronic Optical and Magnetic MaterialsPower (physics)AmplitudeTEORIA DE LA SEÑAL Y COMUNICACIONES0103 physical sciencesSignal generationElectronic engineeringVacuum breakdownPoint (geometry)Electrical and Electronic EngineeringbusinessIEEE Transactions on Electron Devices
researchProduct

A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions

2019

Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…

010302 applied physicsMaterials scienceEquivalent series resistanceAmplifierPenning trap01 natural sciences7. Clean energySignalFourier transform ion cyclotron resonance010305 fluids & plasmasIonCrystal0103 physical sciencesAtomic physicsInstrumentationSensitivity (electronics)Review of Scientific Instruments
researchProduct

Power efficiency improvements with the radio frequency H− ion source

2016

CW 13.56 MHz radio frequency-driven H(-) ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H(-) beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation …

010302 applied physicsMaterials scienceta114ta213Electromagnetbusiness.industryRF power amplifierCyclotronPlasma01 natural sciencesIon sourcelaw.inventionion sourceslawMagnet0103 physical sciencesOptoelectronicsRadio frequencypower efficiency010306 general physicsbusinessInstrumentationElectrical efficiencyReview of Scientific Instruments
researchProduct

Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.

2017

Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsMaterials sciencePreamplifierInstrumentationenergy-resolved photon counting detectordigital pulse shape analysienergy-resolved photon counting detectors01 natural sciencesCharge sharing03 medical and health scienceschemistry.chemical_compoundOpticshigh flux0103 physical sciencesInstrumentationX-ray and ?-ray detectorsNuclear and High Energy Physiccharge sharingRadiationdigital pulse shape analysisPixel010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorSettore FIS/01 - Fisica SperimentaleDetectorX-ray and γ-ray detectorBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc telluridechemistryDirect couplingbusinessJournal of synchrotron radiation
researchProduct

Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors

2018

Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsMaterials sciencePreamplifierPhysics::Instrumentation and Detectors01 natural sciencesCollimated lightCharge sharinglaw.invention03 medical and health scienceschemistry.chemical_compoundOpticslawcharge losse0103 physical sciencesInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy Physiccharge lossescharge sharingRadiationPixel010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica Sperimentaleenergy-resolved photon-counting detectorSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc tellurideX-ray and gamma-ray detectorschemistryDirect couplingbusinessX-ray and gamma-ray detector
researchProduct

Quantification of cortical proprioceptive processing through a wireless and miniaturized EEG amplifier.

2022

Corticokinematic coherence (CKC) is computed between limb kinematics and cortical activity (e.g. MEG, EEG), and it can be used to detect, quantify and localize the cortical processing of proprioceptive afference arising from the body. EEG-based studies on CKC have been limited to lab environments due to bulky, non-portable instrumentations. We recently proposed a wireless and miniaturized EEG acquisition system aimed at enabling EEG studies outside the laboratory. The purpose of this work is to compare the EEG-based CKC values obtained with this device with a conventional wired-EEG acquisition system to validate its use in the quantification of cortical proprioceptive processing. Eleven hea…

AdultMaleMovementlangaton tekniikkaYoung AdultmittauslaitteetElectronicHumansEEGwireless sensor networkslaboratoriesrecordingAmplifiers ElectronicsensoriverkotMagnetoencephalographyElectroencephalographylaboratoriotwireless communicationProprioceptionAmplifiersperformance evaluationaivokuoriAdult; Amplifiers; Electronic; Electroencephalography; Female; Humans; Magnetoencephalography; Male; Movement; Proprioception; Young Adultharmonic analysisFemaleelectroencephalographyAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
researchProduct

Ondes scélérates et statistiques extrêmes dans les systèmes optiques fibrés

2011

This thesis deals with extremes statistics which has become an attractive subject in optics since a comparison with oceanic rogue waves has been proposed at the end of 2007. We report some potential mechanisms stimulating the rogue wave formation in the context of guided propagation of light in optical fibers. In a first part, we explore optical rogue waves in supercontinuums generated by fourth-order modulation instability and we propose a stabilization method based on the use of two continuous seeds. Then, we present a detailed study on Raman fiber amplifiers where we determine the conditions of emergence of giant structures : in presence of a partially incoherent pumping wave, a quasi-in…

Amplificateur RamanOptical fiberNonlinear opticsRogue waves[ PHYS.COND.CM-GEN ] Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other]Raman amplifierExtreme statisticsFibre optiqueStatistiques extrêmesOptique non-linéaire[PHYS.COND.CM-GEN] Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other][PHYS.COND.CM-GEN]Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other]SolitonOndes scélérates
researchProduct

Gain lifetime measurement of a Ni-like Ag soft X-ray laser

2012

International audience; Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations. (C) 2012 Optical Society of America

Amplified spontaneous emissionCODEPhysics::OpticsCurved mirrorBEAM01 natural scienceslaw.inventionCOHERENT010309 opticsLaser linewidthOptics[PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]law0103 physical sciencesSpontaneous emission010306 general physicsPhysics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryAmplifierLaserAtomic and Molecular Physics and OpticsTemporal resolutionOptoelectronicsbusinessExcitationOptics Express
researchProduct

Control of signal coherence in parametric frequency mixing with incoherent pumps: Narrowband mid-infrared light generation by downconversion of broad…

2012

International audience; We study, with numerical simulations using the generalized nonlinear envelope equation, the processes of optical parametric and difference- and sum-frequency generation (SFG) with incoherent pumps in optical media with both quadratic and third-order nonlinearity, such as periodically poled lithium niobate. With ultrabroadband amplified spontaneous emission pumps or continua (spectral widths > 10 THz), group-velocity matching of a near-IR pump and a short-wavelength mid-IR (MIR) idler in optical parametric generation may lead to more than 15-fold relative spectral narrowing of the generated MIR signal. Moreover, the SFG process may also lead to 6-fold signal coherence…

Amplified spontaneous emissionLithium niobatePhysics::Optics01 natural sciences010309 opticsMEDIAchemistry.chemical_compoundOpticsNarrowband0103 physical sciencesSpectral width010306 general physicsPhysicsSum-frequency generationCRYSTALAcoustooptical devices; interferometry; mixer circuitsbusiness.industryQuantum noiseStatistical and Nonlinear PhysicsBEAMSOptical parametric amplifierAtomic and Molecular Physics and OpticsOUTPUTCONTINUUMchemistryOSCILLATORSbusinessPhotonic-crystal fiber
researchProduct