Search results for "Aop"
showing 10 items of 363 documents
Iatrogenic perforation during colonoscopy in the endoscopic suturing era: surgical emergency or endoscopic clinical practice?
2019
Perioperative and Periprocedural Management of Antithrombotic Therapy: Consensus Document of SEC, SEDAR, SEACV, SECTCV, AEC, SECPRE, SEPD, SEGO, SEHH…
2018
During the last few years, the number of patients receiving anticoagulant and antiplatelet therapy has increased worldwide. Since this is a chronic treatment, patients receiving it can be expected to need some kind of surgery or intervention during their lifetime that may require treatment discontinuation. The decision to withdraw antithrombotic therapy depends on the patient's thrombotic risk versus hemorrhagic risk. Assessment of both factors will show the precise management of anticoagulant and antiplatelet therapy in these scenarios. The aim of this consensus document, coordinated by the Cardiovascular Thrombosis Working Group of the Spanish Society of Cardiology, and endorsed by most o…
Protective Mechanical Ventilation during General Anesthesia for Open Abdominal Surgery Improves Postoperative Pulmonary Function
2013
Abstract Background: The impact of intraoperative ventilation on postoperative pulmonary complications is not defined. The authors aimed at determining the effectiveness of protective mechanical ventilation during open abdominal surgery on a modified Clinical Pulmonary Infection Score as primary outcome and postoperative pulmonary function. Methods: Prospective randomized, open-label, clinical trial performed in 56 patients scheduled to undergo elective open abdominal surgery lasting more than 2 h. Patients were assigned by envelopes to mechanical ventilation with tidal volume of 9 ml/kg ideal body weight and zero-positive end-expiratory pressure (standard ventilation strategy) or tidal vol…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Histamine release in mesenteric traction syndrome during abdominal aortic aneurysm surgery: prophylaxis with H1 and H2 antihistamines
2002
Objective and design: Mesenteric traction syndrome is described as sudden tachycardia, hypotension and flush. Among other etiological factors eventeration or mesenteric traction of the small intestine may cause histamine release from mesenteric mast cells. We hypothesized that mesenteric traction syndrome may be positively influenced by prophylactic antihistamine administration.¶Methods: Male patients (n = 17, ASA groups III-IV, 48–78 years old) were investigated in a randomised double blind study during elective abdominal aortic aneurysm (AAA) repair. Eight patients had pre-anaesthetic prophylaxis with dimetindene (H1-receptor antagonist) plus cimetidine (H2-receptor antagonist), 9 patient…
Targeted use of intraoperative frozen-section analysis lowers the frequency of completion thyroidectomy
2021
Abstract Background The impact of intraoperative frozen section (iFS) analysis on the frequency of completion thyroidectomy for the management of thyroid carcinoma is controversial. Although specialized endocrine centres have published their respective results, there are insufficient data from primary and secondary healthcare levels. The aim of this study was to analyse the utility of iFS analysis. Methods In the Prospective Evaluation Study Thyroid Surgery (PETS) 2 study, 22 011 operations for benign and malignant thyroid disease were registered prospectively in 68 European hospitals from 1 July 2010 to 31 December 2012. Group 1 consisted of 569 patients from University Medical Centre (UMC…
Oxidation of carboxylic acids in water at IrO2-Ta2O5 and Boron Doped Diamond anodes
2011
Abstract A detailed study was dedicated to the anodic oxidation of three carboxylic acids (namely, oxalic, formic and maleic acid) with the objective to evaluate in a systematic way the effect on the oxidation of carboxylic acids of numerous relevant parameters, including the nature and the concentration of the carboxylic acid, the alimentation regime (potentiostatic vs. amperostatic), the current density and the working potential values, the flowdynamic regime, the temperature and the nature of the electrode material. It was observed that the effect of some operative parameters strongly depends on the nature of the electrode and of the carboxylic acid. As an example, the efficacy of abatem…
Anesthesia protocols in laboratory animals used for scientific purposes
2018
Background: A suitable, effective and free of complications anesthetic protocol is very important in experimental studies on animal models since it could bias the outcome of a trial. To date there is no universally accepted protocol for induction, maintenance and recovery from anesthesia. The endotracheal intubation with the use of inhalation anesthesia is used very especially in the from of large size laboratory animals, because it is a secure and easy control mode. However, it is not common for small laboratory animals because of the high technical skills required. Aim: The aim of this paper is a review of the main methods of induction of anesthesia in laboratory animals. Materials and me…
Abatement of 1,1,2,2-tetrachloroethane in water by reduction at silver cathode and oxidation at boron doped diamond anode in micro reactors
2012
The treatment of aqueous solutions of 1,1,2,2-tetrachloroethane was performed by anodic oxidation at boron doped diamond (BDD), cathodic reduction at silver and coupled processes. Experiments were performed in macro and micro reactors with an interelectrode distance lower than 100. μm. Drastically higher abatements of the chlorinated compound and current efficiencies were obtained in microdevices that, furthermore, allowed to perform the electrolyses with low cell voltages in the absence of supporting electrolyte. When reduction and oxidation processes were carried out simultaneously in the microreactor, a higher abatement of pollutants was obtained with the same amount of the passed charge…
Improving bleeding detector features for electron intraoperative radiotherapy
2019
Abstract Purpose The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been develope…