Search results for "Aortic Aneurysm"
showing 10 items of 255 documents
Comparison of hemodynamic and structural indices of ascending thoracic aortic aneurysm as predicted by 2-way FSI, CFD rigid wall simulation and patie…
2018
Patient-specific computational modeling is increasingly being used to predict structural and hemodynamic parameters, especially when current clinical tools are not accessible. Indeed, pathophysiology of ascending thoracic aortic aneurysm (ATAA) has been simulated to quantify the risk of complications by novel prognostic parameters and thus to improve the clinical decision-making process related to the intervention of ATAAs. In this study, the relevance of aneurysmal wall elasticity in determining parameters of clinical importance, such as the wall shear stress (WSS), is discussed together with the significance of applying realistic boundary conditions to consider the aortic stretch and twis…
In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta
2017
Objective/Background: The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients.Methods: Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV ( n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 +/- 5.3 mm for BAV and 45.4 +/- 10.0 mm for TAV) were compared…
Focus on the unique mechanisms involved in thoracic aortic aneurysm formation in bicuspid aortic valve versus tricuspid aortic valve patients: clinic…
2013
OBJECTIVES: The involvement of different factors in the onset of thoracic aortic aneurysm (TAA) in patients with a bicuspid aortic valve (BAV) vs those with a tricuspid aortic valve (TAV) is well recognized. However, the molecular, genetic and cellular mechanisms driving TAA remain unclear. The aim of this study was to identify the different mechanisms involved in TAA development in patients with BAV vs TAV. METHODS: Aorta specimens and DNA samples were collected from 24 BAV (18 men and 6 women; mean age: 54.2 ± 14.39 years) and 110 TAV (79 men and 31 women, mean age: 66 ± 9.8 years) patients. A control group of 128 subjects (61 men and 67 woman, mean age: 61.1 ± 5.8 years) was also enrolle…
Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.
2016
OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …
Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve.
2012
The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid–structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolater…
Candida glabrata meningitis and endocarditis: a late severe complication of candidemia
2014
SummaryWe report an unusual case of Candida glabrata meningitis and endocarditis in a young Caucasian woman with a prosthetic aortic valve and suffering from a dissecting thoraco-abdominal aortic aneurysm. C. glabrata was isolated from culture of the cerebrospinal fluid. Candida infection of the central nervous system is an uncommon manifestation of disseminated infection due to Candida species. Our case report also highlights the intrinsic resistance of C. glabrata to azoles.
Modified hemi-Fontan procedure on the beating heart
1998
the heart by infusing the cardioplegic solution under aortic occlusion by means of the balloon throughout the procedure. Even though the balloon catheter passes through the aortic valve, significant aortic valve insufficiency is not likely to occur because of the small caliber of the balloon catheter. We believe that the clinical application of this double-lumen aortic occlusion catheter will protect the myocardium in patients with a thoracoabdominal aortic aneurysm or distal descending aortic aneurysm who undergo the operation through the left thoracotomy with DHCA.
Deep learning approach for the segmentation of aneurysmal ascending aorta.
2020
Diagnosis of ascending thoracic aortic aneurysm (ATAA) is based on the measurement of the maximum aortic diameter, but size is not a good predictor of the risk of adverse events. There is growing interest in the development of novel image-derived risk strategies to improve patient risk management towards a highly individualized level. In this study, the feasibility and efficacy of deep learning for the automatic segmentation of ATAAs was investigated using UNet, ENet, and ERFNet techniques. Specifically, CT angiography done on 72 patients with ATAAs and different valve morphology (i.e., tricuspid aortic valve, TAV, and bicuspid aortic valve, BAV) were semi-automatically segmented with Mimic…
On the severity of aortic stenosis in ascending aortic aneurysm: A computational tool to examine ventricular-arterial interaction and aortic wall str…
2020
Abstract An ascending thoracic aortic aneurysm (ATAA) is a life-threatening cardiovascular consequence of vessel dilatation that portends adverse events and death. From a clinical perspective, ATAA should not be treated as an isolated disease, and surgery is often carried out in the presence of AS, aortic insufficiency or a calcified valve leaflet. Aortic stenosis (AS) is common in ATAAs and leads to both vessel rigidity and left ventricular (LV) impairment. In this study, lumped-parameter modeling and computational analysis were used to assess the change in the wall shear stress (WSS) and intramural wall stress of patient-specific ATAA models with different degrees of AS (i.e., mild to sev…
Constitutive modeling of ascending thoracic aortic aneurysms using microstructural parameters.
2016
Ascending thoracic aortic aneurysm (ATAA) has been associated with diminished biomechanical strength and disruption in the collagen fiber microarchitecture. Additionally, the congenital bicuspid aortic valve (BAV) leads to a distinct extracellular matrix structure that may be related to ATAA development at an earlier age than degenerative aneurysms arising in patients with the morphological normal tricuspid aortic valve (TAV). The purpose of this study was to model the fiber-reinforced mechanical response of ATAA specimens from patients with either BAV or TAV. This was achieved by combining image-analysis derived parameters of collagen fiber dispersion and alignment with tensile testing dat…