Search results for "Aortic valve"
showing 10 items of 179 documents
Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
2019
Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 fram…
Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions
2016
Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely âbicuspid aortopathyâ) is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting fr…
Non-sutureless minimally invasive aortic valve replacement: mini-sternotomy versus mini-thoracotomy: a series of 1130 patients
2016
Objectives Aortic valve replacement through conventional sternotomy still represents the gold-standard surgical approach for aortic valve disease. However, given the increasing number of patients with comorbidities, strategies that can improve operative results are always sought. Minimally invasive aortic valve surgery, although related to a steep learning curve, might be associated with improved postoperative outcomes. The main aim of this study was to assess whether significant differences exist in terms of operative and early results between a mini-sternotomy and a right mini-thoracotomy approach for isolated aortic valve replacement without sutureless technologies. Methods This is an ob…
Histological and genetic studies in patients with bicuspid aortic valve and ascending aorta complications.
2011
OBJECTIVES: Aneurysm diameter and growing rate does not represent a definite parameter for operation in bicuspid aortic valve (BAV), ascending aortic aneurysm and normal root patients. Thus, we investigated histological and immunohistochemical aspects of different segments of ascending aorta (precisely, aortic root without dilatation, aneurysmatic tubular portion, dissected ascending aorta) and genetic features of patients with BAV and ascending aorta complication (aneurysm or dissection). METHODS: Aorta tissue samples of 24 BAV patients were examined. The patients comprised of 18 men and 6 women; the mean age was 54.2 ± 14.3 years. All patients underwent composite aortic root replacement (…
Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…
2008
Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…
Outcomes of Patients With Asymptomatic Aortic Stenosis Followed Up in Heart Valve Clinics
2018
International audience; Importance - The natural history and the management of patients with asymptomatic aortic stenosis (AS) have not been fully examined in the current era. Objective - To determine the clinical outcomes of patients with asymptomatic AS using data from the Heart Valve Clinic International Database. Design, setting, and participants - This registry was assembled by merging data from prospectively gathered institutional databases from 10 heart valve clinics in Europe, Canada, and the United States. Asymptomatic patients with an aortic valve area of 1.5 cm2 or less and preserved left ventricular ejection fraction (LVEF) greater than 50% at entry were considered for the prese…
Modified Danielson Technique for Prosthetic Aortic Valve Endocarditis and Aortoventricular Discontinuity
2020
Endocarditis is a devastating complication of prosthetic aortic valve replacement. The infective process can destroy aortic annulus tissue, making conventional surgical valve replacement difficult or impossible and causing aortoventricular discontinuity. Several treatment techniques have been proposed. One of these, the Danielson technique, involves translocating the aortic valve to the native ascending aorta, débriding the abscess cavity, closing the coronary ostia, and bypassing the coronary arteries with a Y anastomosis between 2 vein grafts. We describe our use of a modified Danielson technique in a 68-year-old man with advanced prosthetic valve endocarditis that was associated with aor…
Supracoronary ascending aortic replacement in patients with acute aortic dissection type A: What happens to the aortic root in the long run?
2013
ObjectiveOur objective was to determine long-term outcome predictors for patients with acute aortic dissection type A (AADA) and aortic root involvement.MethodsFrom 2001 through 2009, 119 of 152 patients operated on for AADA at a tertiary medical center underwent supracoronary ascending aortic replacement (52 women; mean age, 61 ± 15 years). Those with at least 1-year follow-up (n = 97) were retrospectively assessed for preoperative aortic root disease. Follow-up data were assessed for evidence of new-onset aortic root disease by computed tomography and echocardiography, and for reoperation for aortic root disease.ResultsMedian follow-up was 33.8 months (range, 0-112 months). Twenty-six (27…
Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences
2011
OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…
ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA
2009
This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…