Search results for "Aperture"

showing 10 items of 182 documents

All-optical super resolved and extended depth of focus imaging with random pinhole array aperture

2008

In this paper, we present a novel approach which allows combining super resolved imaging with extended depth of focus while the result is obtained by all-optical means and no digital processing is required. The presented approach for the super resolved imaging includes attaching a random pinhole array plate to the aperture plane of the imaging system. The energetic efficiency of the system is high and it is much larger than an imaging through a single pinhole which also has extended depth of focus. The super resolving result is obtained by mechanic scanning of the aperture plane with the random plate.

PhysicsExtended depth of focusArray aperturebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage processingSuperresolutionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsAll opticalOpticsAperture planePinhole (optics)Electrical and Electronic EngineeringPhysical and Theoretical ChemistrybusinessImage resolutionOptics Communications
researchProduct

On-axis diffractional behavior of two-dimensional pupils

2010

We show that, at any Fresnel number, a suitable one-dimensional Fourier transform relates the complex-amplitude distribution along the optical axis with the zero-order circular harmonic of the amplitude transmittance of a two-dimensional diffracting screen. First, our general result is applied to recognize that any rationally nonsymmetric screen generates an axial-irradiance distribution that exhibits focal shift. In this way we identify a wide set of two-dimensional screens that produce the same focal shift as that produced by the clear circular aperture. Second, we identify several apodizers for shaping the axial-amplitude distribution. We discuss some examples for achieving high-precisio…

PhysicsFresnel zoneAperturebusiness.industryMaterials Science (miscellaneous)Astrophysics::Instrumentation and Methods for AstrophysicsFresnel integralIndustrial and Manufacturing EngineeringOptical axissymbols.namesakeOpticsFourier transformApodizationsymbolsFresnel numberBusiness and International ManagementFocus (optics)businessApplied Optics
researchProduct

Determination of IBIS mask transmission matrix

2005

The high-angular resolution imager IBIS is one of the two main instruments aboard the ESA INTEGRAL satellite launched in October 2002. IBIS uses coded aperture mask technique in order to provide the required imaging capabilities for energies between 15 and 10 MeV.The precise knowledge of the coded mask response function critically determine the IBIS imaging performances. In this paper, we present a general description of the IBIS coded mask design together with its main features. Transparency and homogeneity values of the IBIS mask flight model from our laboratory measurements are presented with indication of the instrumental set-up used and accuracy achieved. Mask transmission as a functio…

PhysicsIbisNuclear and High Energy PhysicsPhotonbiologybusiness.industryAstrophysics::High Energy Astrophysical PhenomenaMonte Carlo methodAstrophysics::Instrumentation and Methods for Astrophysicsbiology.organism_classificationIntegrated circuit layoutOpticsTransmission (telecommunications)SatelliteCoded aperturebusinessInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

JEM–X: The X-ray monitor aboard INTEGRAL

2003

The JEM-X monitor provides X-ray spectra and imaging with arcminute angular resolution in the 3 to 35 keV band. The good angular resolution and the low energy response of JEM-X plays an important role in the identification of gamma ray sources and in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture instrument consisting of two identical, coaligned telescopes. Each of the detectors has a sensitive area of 500 cm 2 , and views the sky through its own coded aperture mask. The two coded masks are inverted with respect to each other and provides an angular resolution of 3 0 across an eective field of view of about 10 diameter.

PhysicsInstrumentation: detectors; X-rays: general;010504 meteorology & atmospheric sciencesSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaResolution (electron density)Astrophysics::Instrumentation and Methods for AstrophysicsGamma rayAstronomy and AstrophysicsField of viewCosmic rayAstrophysics01 natural sciencesParticle detectorOpticsSpace and Planetary Science0103 physical sciencesAngular resolutionCoded aperturebusiness010303 astronomy & astrophysics0105 earth and related environmental sciencesAstronomy & Astrophysics
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

In vitro power profiles of multifocal simultaneous vision contact lenses.

2013

Abstract Purpose To evaluate the power profile of multifocal contact lenses (CLs) using a new technology based on quantitative deflectometry. Methods The Nimo TR1504 was used to analyze the power distribution of multifocal CLs. The CLs under study were: Air Optix Aqua Multifocal Low, Medium and High Addition and Focus Progressives. Three lenses of each model were considered. Results All multifocal CLs showed a power profile characterized by a change toward more positive power values when aperture sizes become smaller. The near refractive addition of the lenses under study was +2.61 D, +1.44 D, +1.30 D and +0.30 D for the Focus Progressives, the Air Optix Aqua Multifocal High, Medium Add and…

PhysicsLightbusiness.industryApertureContact LensesOptical powerGeneral MedicinePresbyopiaEquipment Designmedicine.diseaseDistance correctionlaw.inventionPower (physics)Lens (optics)Equipment Failure AnalysisOphthalmologyRefractometryOpticslawmedicineScattering RadiationbusinessFocus (optics)OptometryNominal power (photovoltaic)Contact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Common-path phase-shifting digital holographic microscopy: A way to quantitative phase imaging and superresolution

2008

We present an experimental setup useful for complex amplitude evaluation and phase image quantification of three-dimensional (3-D) samples in digital holographic microscopy (DHM). It is based on a common-path interferometric configuration performed by dividing the input plane in two contiguous regions and by placing a translation grating near to the Fourier plane. Then, complex amplitude distribution of the sample under test is recovered with phase-shifting standard method obtained by moving the grating using a linear motion stage. Some experimental results of an USAF resolution test are presented for different numerical aperture (NA) microscope lenses. In a second part, the proposed setup …

PhysicsMicroscopebusiness.industryFourier opticsHolographyGratingAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionNumerical apertureLens (optics)OpticslawDigital holographic microscopyElectrical and Electronic EngineeringPhysical and Theoretical ChemistrybusinessImage resolutionOptics Communications
researchProduct

Filter performance parameters for vectorial high-aperture wave fields.

2008

Performance parameters have been presented that can be used to compare the focusing performance of different optical systems, including the effect of pupil filters. These were originally given for the paraxial case and recently extended to the high-aperture scalar regime. We generalize these parameters to the full vectorial case for an aplanatic optical system illuminated by a plane-polarized wave. The behavior of different optical systems is compared.

PhysicsMicroscopyParabolic reflectorAperturebusiness.industryParaxial approximationScalar (physics)Physics::OpticsSignal Processing Computer-AssistedFilter (signal processing)Image EnhancementAtomic and Molecular Physics and OpticsOpticsElectric fieldImage Interpretation Computer-AssistedOptical filterbusinessImage resolutionAlgorithmsFiltrationOptics letters
researchProduct

The INTEGRAL experiment

1998

The International Gamma-ray Astrophysics Laboratory (INTEGRAL) is conceived as the next logical step in gamma-ray astronomy after the US Compton Gamma-Ray Observatory (CGRO) and the French/Russian SIGMA mission. The INTEGRAL scientific payload consists of two main instruments (Imager and Spectrometer) and two monitor instruments (X-Ray Monitor and Optical Transient Camera). The INTEGRAL spectrometer "SPI" is optimized for detailed measurements of gamma-ray lines and mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high-purity germanium detectors. The detectors make precise measurements of the gamma-ray energies over the 20 keV-8 MeV energy range. …

PhysicsNuclear and High Energy PhysicsSpectrometerPayloadbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaMonte Carlo methodDetectorAstrophysics::Instrumentation and Methods for AstrophysicsAtomic and Molecular Physics and OpticsOpticsObservatoryAngular resolutionCoded apertureTransient (oscillation)business
researchProduct

A coded mask for γ-ray astronomy. Design and calibration

2003

Abstract The high-resolution γ-ray spectrometer (SPI) is one of the two main instruments on board the ESA INTEGRAL satellite successfully launched in October 2002. SPI uses coded aperture mask technique in order to have imaging capabilities at the energy band (20 keV–8 MeV) it will study celestial sources. The SPI imaging performance depends critically on the quality of the coded mask response and also on the precise knowledge of such response function. In this paper we present a general description of the SPI Coded Mask design together with its main features. Scientific impact of INTEGRAL SPI Coded Mask design on the instrument capabilities is also discussed. Results obtained for Mask cali…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsIntegrated circuit layoutOn boardOpticsQuality (physics)CalibrationSatelliteCoded aperturebusinessInstrumentationRemote sensingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct