Search results for "Applied Physics"
showing 10 items of 1226 documents
Determination of Contact Potential Difference by the Kelvin Probe (Part I) I. Basic Principles of Measurements
2016
Abstract Determination of electric potential difference using the Kelvin probe, i.e. vibrating capacitor technique, is one of the most sensitive measuring procedures in surface physics. Periodic modulation of distance between electrodes leads to changes in capacitance, thereby causing current to flow through the external circuit. The procedure of contactless, non-destructive determination of contact potential difference between an electrically conductive vibrating reference electrode and an electrically conductive sample is based on precise control measurement of Kelvin current flowing through a capacitor. The present research is devoted to creation of a new low-cost miniaturised measuremen…
Luminescence of divalent lanthanide doped BaBrI single crystal under synchrotron radiation excitations
2020
Abstract Luminescence excitation spectra of BaBrI single crystals doped by divalent lanthanide ions are studied using synchrotron radiation excitations from the MAX IV 1.5 GeV storage ring. The energy of the edge and the formation of core cation exciton as well as the energy threshold of the multiplications of electronic excitations is found. It was clearly established the energy transfer from intrinsic luminescence centers to Sm2+ and Eu2+ ions.
Atomic Layer Deposition and Properties of Lanthanum Oxide and Lanthanum-Aluminum Oxide Films
2006
Atomic layer deposition (ALD) of lanthanum oxide on glass and silicon substrates was examined using lanthanum silylamide, La[N(SiMe 3 ) 2 ] 3 , and water as precursors in the substrate temperature range of 150-250 °C. The effect of pulse times and precursor evaporation temperature on the growth rate and refractive index was investigated. The films remained amorphous regardless of the deposition conditions. The resulting La 2 O 3 films contained noticeable amounts of hydrogen and silicon and were chemically unstable while stored in ambient air. Lanthanum aluminum oxide films were achieved with stoichiometry close to that of LaAlO 3 at 225°C from La[N(SiMe 3 ) 2 ] 3 , Al(CH 3 ) 3 , and H 2 O.…
Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method.
2021
Abstract Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is one of the methods that have been used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described, and it is briefly compared with other commonly used frequency extraction methods. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytical…
Laser Ultrasonics Inspection for Defect Evaluation on Train Wheel
2019
Abstract Passengers’ safety and in-service life of wheelset axles play an important role in railway vehicles. For this reason, periodic inspections are necessary. Among non-destructive techniques, ultrasonic ones are widely applied in this field. The main disadvantage of conventional ultrasonic techniques is that the overall inspection of wheels requires the train to be put out-of-service and disassembly each part, which is time-consuming and expensive. In this paper, a non-conventional non-contact laser ultrasonic inspection for train wheels is proposed. The proposed method uses a laser interferometer to receive the ultrasonic wave without contact. The receiving system allows choosing the …
New fine structures resolved at the ELNES Ti-L2,3 edge spectra of anatase and rutile: comparison between experiment and calculation.
2010
Abstract Anatase and rutile Ti- L 2,3 edge spectra were measured in electron energy loss spectroscopy (EELS) using a transmission electron microscope (TEM) coupled to a CEOS Cs-probe corrector, an omega-type monochromator and an in-column omega-type energy filter fully corrected for 2nd order aberrations. Thanks to the high energy resolution, high electron probe current and high stability achieved under this instrumental configuration, new fine structures, never reported before, were resolved at the L 3 band of both rutile and anatase. The data suggest that new peaks also exist in the L 2 e g band. The experimental spectra are compared with multichannel multiple scattering (MMS) calculation…
Exploring the transport properties of equatorially low coordinated erbium single ion magnets
2019
Single-molecule spin transport represents the lower limit of miniaturization of spintronic devices. These experiments, although extremely challenging, are key to understand the magneto-electronic properties of a molecule in a junction. In this context, theoretical screening of new magnetic molecules provides invaluable knowledge before carrying out sophisticated experiments. Herein, we investigate the transport properties of three equatorially low-coordinated erbium single ion magnets with C3v symmetry: Er[N(SiMe3)2]3 (1), Er(btmsm)3 (2) and Er(dbpc)3 (3), where btmsm=bis(trimethylsilyl)methyl and dbpc=2,6-di-tert-butyl-p-cresolate. Our ligand field analysis, based on previous spectros…
Magnetization switching behavior with competing anisotropies in epitaxial Co3FeN/MnN exchange-coupled bilayers
2016
Key factors towards a high-quality additive manufacturing process with ABS material
2019
Abstract Additive Manufacturing technologies have gained a lot of popularity during the past years. The current challenge being the transition of this manufacturing technology from prototype oriented towards mass production. In order to achieve this, fabrication times and mechanical parameters must be improved. This paper aims to identify which are the parameters that have the highest influence on parts obtained with fused deposition modeling (FDM) technology from ABS material. In addition, this study identifies which are the most accurate methods to test the mechanical properties of FDM parts while still respecting ASTM standard for testing the tensile properties of plastics. It was found …
Binocular function measures as predictors of user performance in stereoscopic augmented reality
2021
Inconsistency between the binocular and focus cues in stereoscopic augmented reality overburdens the visual system leading to its stress. However, a high individual variability of tolerance for visual stress makes it difficult to predict and generalize the user gain associated with the implementation of alternative visualization technologies. In this study, we investigated the relationship between the binocular function and perceptual judgments in augmented reality. We assessed the task completion time and accuracy of perceptual distance matching depending on the consistency of binocular and focus cues in the stereoscopic environment of augmented reality. The head-mounted display was driven…