Search results for "Applied Physics"
showing 10 items of 1226 documents
Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs
2018
In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…
Depth profiles of damage creation and hardening in MgO irradiated with GeV heavy ions
2019
This work has been performed within the framework of the EUROfusion Enabling Research project: ENR-MFE19.ISSP-UL-02 “Advanced experimental and theoretical analysis of defect evolution and structural disordering in optical and dielectric materials for fusion applications”. The views and opinions expressed herein do not necessarily reflect those of the European Commission.
Radiation-induced defects in sapphire single crystals irradiated by a pulsed ion beam
2020
Abstract The luminescence and thermal stability of defects formed in α-Al2O3 single crystals after powerful (300 keV) pulsed irradiation with C+/H+ ion beam were investigated. It was found by measuring of optical density, photoluminescence, and pulsed cathodoluminescence that ion irradiation induces both single F-, F+-centers and F2-type aggregate centers. An intense thermoluminescence band with a complex shape was observed in the broad temperature range of 350–700 K, its intensity decreases with increasing of the energy density of the ion beam. The thermal stability of the F-type defects produced in α-Al2O3 after irradiation with a pulsed ion beam is comparable to that in neutron-irradiate…
Analysis of 7Be and 210Pb concentration and 7Be/210Pb activity ratio in ground level air in Palermo (Italy)
2019
A series of measurements of particulate samples collected on paper filters in Palermo (Italy) during 1995–2005 has been performed to detect 210Pb air activity concentration and, along with previous similar data on 7Be, to evaluate their activity ratio. Average values for the daily activity concentrations of 7Be and 210Pb are found to be 4.7 and 0.6 mBq/m3 , respectively, 9.8 being the average activity ratio. Data confirm a seasonal behavior for both radionuclides. A correlation between 7Be and 210Pb air activity concentrations seems to exist, despite their different origins. The time behaviors of both 7Be and 210Pb air concentrations and 7Be/ 210Pb activity ratio have been compared with som…
Theoretical and experimental studies of the neutron rich fission product yields at intermediate energies
2012
A new method to measure the fission product independent yields employing the ion guide technique and a Penning trap as a precision mass filter, which allows an unambiguous identification of the nuclides is presented. The method was used to determine the independent yields in the proton-induced fission of 232 Th and 238 U at 25 MeV. The data were analyzed with the consistent model for description of the fission product formation cross section at the projectile energies up to 100 MeV. Pre-compound nucleon emission is described with the two-component exciton model using Monte Carlo method. Decay of excited compound nuclei is treated within time-dependent statistical model with inclusion of the…
Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case
2017
This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…
Impact of the molecular structure of an indandione fragment containing azobenzene derivatives on the morphology and electrical properties of thin fil…
2016
Abstract The solution casting method is low-cost processing method. Moreover, it is possible to prepare amorphous thin films by using this method, and thus, both optical quality and electrical properties could be improved in compare to polycrystalline films made by thermal evaporation in vacuum. Therefore, low-molecular-weight compounds that form amorphous structure from solution could be promising in organic electronics. In this work film morphology, molecule energy levels, and charge carrier mobility in thin films of indandione fragment containing azobenzene derivatives were studied. Deep charge carrier trapping states that drastically influenced charge carrier mobility were observed for …
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
2019
Background The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. Material and methods 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then e…
On the solution of a parabolic PDE involving a gas flow through a semi-infinite porous medium
2021
Abstract Taking as start point the parabolic partial differential equation with the respective initial and boundary conditions, the present research focuses onto the flow of a sample of waste-water derived from a standard/conventional dyeing process. In terms of a highly prioritized concern, meaning environment decontamination and protection, in order to remove the dyes from the waste waters, photocatalyses like ZnO or TiO2 nanoparticles were formulated, due to their high surface energy which makes them extremely reactive and attractive. According to the basics of ideal fluid, the key point is the gas flow through an ideal porous pipe consisting of nanoparticles bound one to each other, for…
Strain detection in non-magnetic steel by Kerr-microscopy of magnetic tracer layers
2018
Abstract For many applications of steel, e.g. for the evaluation of the fatigue state of components or structures, the characterization of the microscopic strain distribution in the material is important. We present a proof-of-principle for the visualization of such strain distributions by Kerr-microscopy of ferromagnetic tracer layers on nonmagnetic steel sheets. The influence of indentation induced strain on the magnetic domain pattern of 20 nm Galfenol and Permalloy tracer layers on austenitic AISI 904L steel sheets was investigated. The obtained Kerr-microscopy images show a characteristic domain pattern in the strained regions of the steel sheets, which is consistent with a dominant ma…