Search results for "Arena"

showing 10 items of 68 documents

Mid- and Longer-term Follow up of Chimney and/or Periscope Grafts and Risk Factors for Failure

2016

Objective The aim was to report on chimney and periscope grafts (CPGs) and their mid- and longer-term outcomes when they are used to preserve reno-visceral artery (RVA) perfusion in endovascular repair of pararenal (PRAAs) or thoraco-abdominal aortic aneurysm (TAAAs). In addition, factors associated with CPG failure are presented. Limited data exist on the outcomes of CPGs, and mid- and long-term results are generally not reported. Methods This was a prospective study in a cohort of 100 patients with PRAA (69) or TAAA (31). A total of 224 (mean 2.24 per patient) RVAs were preserved with 136 (61%) chimney and 88 (39%) periscope grafts. CPGs were constructed mainly using self expandable stent…

MalePercutaneousmedicine.medical_treatment030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRenal ArteryRisk FactorsOcclusion030212 general & internal medicineTreatment FailureProspective cohort studyAortaPararenal aortic aneurysm10042 Clinic for Diagnostic and Interventional RadiologyReno2746 SurgeryAortic AneurysmFemaleRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialty610 Medicine & health2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesEndovascular aneurysm repairabdominal aortic aneurysmAneurysmChimney and periscope graftChimney and periscope graft; Complex aortic aneurysm; Endovascular aneurysm repair; Pararenal aortic aneurysm; Reno-visceral arteries; Thoraco-abdominal aortic aneurysm; Cardiology and Cardiovascular Medicine; SurgerymedicineHumansAgedRetrospective StudiesReno-visceral arterieThoraco-abdominal aortic aneurysmbusiness.industryComplex aortic aneurysmStentRetrospective cohort studyThoracomedicine.diseaseSurgeryvisceral arteriesSurgeryVascular GraftingbusinessFollow-Up Studies
researchProduct

Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results

2018

Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…

MaleTime Factorsabdominal aortic aneurysm; chimney graft; chimney technique; endoleak; endovascular aneurysm repair; juxtarenal aortic aneurysm; parallel graft; pararenal aortic aneurysm; periscope graft; snorkel graftmedicine.medical_treatmentJuxtarenal aortic aneurysm030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repair0302 clinical medicineRisk FactorsRetrospective analysisChimneyRegistries030212 general & internal medicineAged 80 and overEndovascular ProceduresChimney graftAbdominal aortic aneurysmEuropeTreatment Outcomesnorkel graftFemaleStentsjuxtarenal aortic aneurysmCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyparallel graftendoleakperiscope graftProsthesis Designpararenal aortic aneurysmBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmchimney techniquemedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industrychimney graftmedicine.diseaseUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm

2010

Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…

MaleTime Factorsmedicine.medical_treatmentShort neckFenestrated graftKaplan-Meier EstimateOPEN REPAIREndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmEVARNetherlandsAged 80 and overMedicine(all)medicine.diagnostic_testENDOGRAFT REPAIRMiddle AgedJuxtarenalAbdominal aortic aneurysmProsthesis FailureTreatment OutcomeFemaleKidney DiseasesStentsCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyAortographyArterial Occlusive DiseasesFenestrated graftsProsthesis DesignAortographyRisk AssessmentBlood Vessel Prosthesis ImplantationAneurysmRenal DialysisBlood vessel prosthesismedicineHumanscardiovascular diseasesAgedRetrospective Studiesbusiness.industryStentENDOVASCULAR REPAIRmedicine.diseaseAneurysmBlood Vessel ProsthesisSurgeryAbdominal aortic aneurysmSurgerybusinessTomography Spiral ComputedAortic Aneurysm AbdominalAbdominal surgeryEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Results of chimney endovascular aneurysm repair as used in the PERICLES Registry to treat patients with suprarenal aortic pathologies

2020

Background: The prevailing evidence calls for using chimney/snorkel endovascular repair (ch-EVAR) with one or two chimney grafts. No studies up to now focus on its applicability and results for the treatment of suprarenal aortic pathologies (SRAP). Hence, we evaluated the clinical and radiologic results of ch-EVAR treatment for SRAP placing three or more chimney grafts within the PERICLES Registry. Methods: Data from 517 patients suffering complex aortic pathologies treated by ch-EVAR between 2008 and 2014 at 13 European and U.S. centers were retrospectively reviewed and analyzed. Results: Sixty-seven ch-EVAR-treated patients (12.9% of the entire PERICLES cohort) presented SRAP (83.5% elect…

MaleTime Factorsmedicine.medical_treatmentTechnical success030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolarePostoperative ComplicationsRenal Artery0302 clinical medicineRisk FactorsSuperior mesenteric arteryChimneyRegistries030212 general & internal medicineSuperior mesenteric arteryAged 80 and overTriple chimney EVARIncidence (epidemiology)Endovascular ProceduresChimney graftEuropeSuprarenal aneurysmsTreatment OutcomeCohortFemaleStentsCardiology and Cardiovascular Medicinemedicine.medical_specialtyAortic DiseasesProsthesis DesignBlood Vessel Prosthesis Implantation03 medical and health sciencesAneurysmMesenteric Artery Superiormedicine.arterymedicineHumansComplex aneurysmAgedRetrospective StudiesSuprarenal aneurysmbusiness.industryComplex aneurysms; Multiple chimney EVAR; Superior mesenteric artery; Suprarenal aneurysms; Triple chimney EVARmedicine.diseaseMultiple chimney EVARUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessComplex aneurysms
researchProduct

CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease.

1997

The purpose of this study was to evaluate the accuracy of CT angiography (CTA) with a single helical acquisition for assessment of stenoses and occlusions of the iliac arteries.In our prospective study, intraarterial digital subtraction angiography and IV CTA were performed from the suprarenal aorta to below the femoral bifurcation in 30 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were also obtained. The accuracy of CTA with and without analysis of axial images was determined.Sensitivity and specificity of CTA were 100% for iliac artery occlusions with a confidence interval 85-100% and 97-100%, respectively. When axial scans were interpret…

Malemedicine.medical_specialtyAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive DiseasesIliac ArterySensitivity and SpecificitySuprarenal Aortamedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAorta AbdominalProspective StudiesObserver VariationAortamedicine.diagnostic_testbusiness.industryVascular diseasemusculoskeletal neural and ocular physiologyAngiographyAngiography Digital SubtractionGeneral MedicineDigital subtraction angiographyMiddle Agedmedicine.diseaseStenosisAngiographyArterial Occlusive DiseasesRadiologybusinessTomography X-Ray Computedpsychological phenomena and processesAJR. American journal of roentgenology
researchProduct

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.

2021

Background Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. Methods This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. Results A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were sim…

Malemedicine.medical_specialtyTime FactorsRenal infarctionmedicine.medical_treatmentUrologyRenal function030204 cardiovascular system & hematologyKidneyEndovascular aneurysm repair030218 nuclear medicine & medical imagingAccessory renal artery03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineRenal ArterymedicineHumansStage (cooking)Renal Insufficiency ChronicSuprarenal fixationAgedRetrospective StudiesAged 80 and overAortic aneurysm repairbusiness.industryEndovascular Proceduresfood and beveragesGeneral Medicinebiochemical phenomena metabolism and nutritionmedicine.diseaseAortic AneurysmBlood Vessel Prosthesiscarbohydrates (lipids)Treatment OutcomeDisease ProgressionSurgeryFemaleCardiology and Cardiovascular MedicinebusinessKidney diseaseGlomerular Filtration RateAnnals of vascular surgery
researchProduct

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

Monitoring the complexities: Nuclear power and public opinion

2009

Interaction between organizations and stakeholders today takes place on virtual and physical ‘issue arenas’. This study examined opinions on nuclear power and asked who are the players discussing nuclear power in Finland? Through content analysis, surveys and interviews, the study concluded that politicians, power companies and regulators were the ones with voice, as NGOs and citizens were hardly heard. The paper suggests the future role of PR practitioners to be to find the right issue arenas and facilitate corporate voice and reputation on those arenas. peerReviewed

MarketingOrganizational Behavior and Human Resource Managementsidosryhmäteoriabusiness.industryluotausCommunicationmedia_common.quotation_subjectmonitorointiPublic relationsNuclear powerPublic opinionPower (social and political)IssuesContent analysisPolitical scienceIssue arenaStakeholder theorymaineNuclear powerbusinessydinvoimaStakeholder theoryReputationmedia_common
researchProduct

Investigation of the hemodynamic flow conditions and blood-induced stresses inside an abdominal aortic aneurysm by means of a SPH numerical model.

2019

The estimation of blood flow-induced loads occurring on the artery wall is affected by uncertainties hidden in the complex interaction of the pulsatile flow, the mechanical parameters of the artery, and the external support conditions. To circumvent these difficulties, a specific tool is developed by combining the aorta displacements measured by an electrocardiogram-gated-computed tomography angiography, with the blood velocity field computed by a smoothed particle hydrodynamics (SPH) numerical model. In the present work, the SPH model has been specifically adapted to the solution of the 3D Navier-Stokes equations inside a domain with boundaries of prescribed motion. Images of the abdominal…

Materials scienceTime FactorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBiomedical EngineeringPulsatile flowHemodynamicsSettore ICAR/01 - IdraulicaPhysics::Fluid DynamicsAneurysmDiastolemedicine.arterymedicineShear stressPressureHumansComputer SimulationMolecular BiologyAortamedicine.diagnostic_testCardiac cycleApplied MathematicsHemodynamicsModels CardiovascularMechanicsmedicine.diseaseAbdominal aortic aneurysmBiomechanical PhenomenaComputational Theory and MathematicsModeling and SimulationAngiographycardiovascular systemHydrodynamicsStress MechanicalInfrarenal abdominal aorta aneurysm shear stresses arterial wall SPH moving boundarySoftwareAlgorithmsBlood Flow VelocityAortic Aneurysm AbdominalInternational journal for numerical methods in biomedical engineeringREFERENCES
researchProduct