Search results for "Argo"

showing 10 items of 424 documents

Influence of annealing atmosphere on photoelectrochemical response of TiO2 nanotubes anodized under controlled hydrodynamic conditions

2021

[EN] The influence of three annealing atmospheres (air, nitrogen and argon) and the use of controlled hydrodynamic conditions (from 0 to 5000 rpm) on morphological, structural, chemical and photoelectrochemical properties of TiO2 nanotubes have been evaluated. For this purpose, different characterization techniques have been used: Field Emission Scanning Electron Microscopy, Raman Confocal Laser Spectroscopy, X-Ray Diffraction, X-Ray Photoelectron Spectroscopy, Incident Photon-to-electron Conversion Efficiency measurements, ultraviolet-visible absorption spectra, Mott-Schottky analysis and photoelectrochemical water splitting tests. According to the results, it can be concluded that both hy…

ArgonAbsorption spectroscopyAnnealing (metallurgy)General Chemical EngineeringPhysics::Opticschemistry.chemical_elementThermal treatmentHydrodynamic conditions photoelectrochemical water splittingINGENIERIA QUIMICAAnalytical ChemistryAnnealing atmosphereCondensed Matter::Materials Sciencesymbols.namesakechemistryX-ray photoelectron spectroscopyChemical engineeringTiO2 nanotubesPhysics::Atomic and Molecular ClustersElectrochemistrysymbolsWater splittingAnodizationSpectroscopyRaman spectroscopyJournal of Electroanalytical Chemistry
researchProduct

Sorption of argon and nitrogen on network types of zeolites and aluminophosphates

1991

Abstract Synthetic zeolites and aluminophosphates comprising 10- and 12- membered ring openings, unidimensional and network type of pore systems (MFI, MEL, ERI, LTA, AEL, AFI and FAU) were used as model adsorbents to examine the impact of micropore structure on the sorption properties. Argon and nitrogen were employed as adsorptives. Adsorption measurements were carried out on gravimetric and volumetric sorption devices and also monitored by microcalorimetry. From the low coverage regime of the isotherm Henry's constants and isosteric heats of adsorption were derived. Both quantities allowed the discrimination between 10- and 12- membered ring systems. Unidimensional 10- and 12- membered ri…

ArgonAdsorptionchemistryInorganic chemistryNeutron diffractionchemistry.chemical_elementPhysical chemistryGravimetric analysisSorptionMicroporous materialMolecular sieveNitrogen
researchProduct

Studies of the bromine spectrum and determination of transition probabilities for Br I and Br II lines

1999

In a wall-stabilized cascade arc at atmospheric pressure in mixtures of argon and bromine vapors thermal plasmas were generated. Arc currents between 25 and 60 A were used. Applying a spectrometer of medium dispersion, equipped with an optical multichannel analyzer (CCD detector), the spectra of neutral and singly ionized bromine in the range between 3300 and 10400 A were recorded. Line intensity measurements, corrected for self-absorption, at different operating conditions of the arc, were performed. A complete set of Br I transitions (5 lines) originating from a common upper level (branching fractions) was measured. In the case of the Br II spectrum intensities of 14 lines were determined…

ArgonBromineMaterials sciencechemistryAtmospheric pressureSpectrometerIonizationGeneral Physics and Astronomychemistry.chemical_elementPlasmaAtomic physicsAbsolute scaleSpectral line
researchProduct

Sensitivity of noble gas NMR parameters to the heterocyclic ring proximity. Density functional theory studies of Ne–furan and Ar–furan complexes

2014

Theoretical modeling of noble gas interaction with furan as a simple heterocyclic ring was performed. The structures of neon–furan and argon–furan complexes were calculated at the MP2, M06-2X, CAM-B3LYP, APFD, and VSXC levels of theory using 6-311++G** basis set. The predicted 21Ne and 39Ar NMR chemical shifts for the Ne–furan and Ar–furan complexes calculated with pcS-3 and aug-pcS-3 basis sets were sensitive to the presence of the aromatic furan ring. Our results indicate a higher sensitivity of the neon and argon NMR probes than the previously reported 3He NMR spectroscopic parameters in studies of small heterocyclic rings containing the oxygen atom.

ArgonCarbon-13 NMR satellitemolecular modelingChemical shiftfuranOrganic Chemistry39Ar NMR spectrachemistry.chemical_elementNoble gasRing (chemistry)chemistry.chemical_compoundNeonchemistryComputational chemistryFuran21Ne NMR spectraGIAO NMR calculationsDensity functional theoryChemistry of Heterocyclic Compounds
researchProduct

Light-induced opening and closing of the intramolecular hydrogen bond in glyoxylic acid.

2013

The isomerization process of glyoxylic acid (GA) conformers and their complexes with a water molecule were studied in a low temperature argon matrix. The research target was to understand how starting conformation and complexation affects the near-IR (NIR) induced conformer interconversion. The most stable GA conformer (Tc) is characterized by an intramolecular hydrogen bond, and it is found to undergo light-induced conformer interconversion slower than the open (Tt) conformer. Upon complexation with water, the isomerization processes slow down in the case of the Tc conformer, whereas for the Tt-based complex the influence of water is negligible on the isomerization process.

ArgonChemistryHydrogen bondchemistry.chemical_elementPhotochemistrychemistry.chemical_compoundIntramolecular forceLight inducedMoleculePhysical and Theoretical ChemistryConformational isomerismIsomerizationta116Glyoxylic acidThe journal of physical chemistry. A
researchProduct

High Resolution Sorption Studies of Argon and Nitrogen on Large Crystals of Aluminophosphate AlPO4-5 AND ZEOLITE ZSM-5

1989

High resolution adsorption (HRADS) with argon and nitrogen at 77 K in the pressure range of 10−6 < p/p° < 0.5 were performed on large crystals of zeolite ZSM-5 (180 μm) and aluminophosphate AlPO4-5 (150 μm) using a novel volumetric device. Multi-step isotherms of both adsorptives on ZSM-5 could be observed for the first time. The adsorption followed by low temperature microcalorimetry resulted in distinct exothermic signals at the steps in the adsorption isotherms. Based on the results of atom-atom potential energy calculations (AAP) as well as independent model building it was shown that 24 ‘kinetic’ adsorbate molecules can be filled into a ZSM-5 unit cell. Experimental results are reasona…

ArgonChemistryInorganic chemistryAnalytical chemistrychemistry.chemical_elementLangmuir adsorption modelSorptionMolecular sieveNitrogensymbols.namesakeAdsorptionsymbolsZSM-5Zeolite
researchProduct

High-resolution sorption studies of argon and nitrogen on large crystals of microporous zeolite ZSM-5

1989

High resolution adsorption (HRADS) with argon and nitrogen at 77 K were performed on large crystals of zeolite ZSM-5 using a novel volumetric device. Multi-step isotherms for both adsorptives could be observed for the first time. The micropore filling was followed by low temperature microcalorimetry. Exothermic heats of adsorption were found to be correlated with steps in the adsorption isotherms. Based on results from atom-atom potential energy calculations (AAP) as well as from independent model building it is shown that 24 kinetic adsorbate molecules can be situated in a ZSM-5 unit cell. Localized adsorption is presented as possible filling mechanisms. Experimental results are reasonably…

ArgonClinical BiochemistryInorganic chemistryAnalytical chemistryLangmuir adsorption modelchemistry.chemical_elementSorptionGeneral MedicineMicroporous materialNitrogenAnalytical Chemistrysymbols.namesakeAdsorptionchemistrysymbolsGeneral Materials ScienceZSM-5ZeoliteFresenius' Zeitschrift für analytische Chemie
researchProduct

Determination of the number densities of argon metastables in argon-hydrogen plasma by absorption and self-absorption methods

2006

The number densities of Ar 3s23p54s levels have been measured by means of two methods: a self-absorption method with a mirror behind the discharge vessel and an absorption method with a high-frequency electrodeless discharge lamp. Concentrations ranging from 6 × 107–4 × 109 cm−3 were obtained for the Ar 3s23p54s levels, depending on the argon content (10–100% Ar) in Ar/H2 microwave plasma. The populations of various sublevels of measured resonant and metastable states coincide within the experimental errors. It was observed that values from measurements of both methods are in good agreement.

ArgonGas-discharge lampAnalytical chemistrychemistry.chemical_elementPlasmaCondensed Matter PhysicsIon sourcelaw.inventionchemistrylawMetastabilityDensity of statesPlasma diagnosticsAbsorption (electromagnetic radiation)Plasma Sources Science and Technology
researchProduct

Measurements of transition probabilities for two N I infrared transitions and their application for diagnostics of low temperature plasmas

2010

Abstract Spectra emitted from a wall-stabilized arc, running in a gas mixture of helium, argon, nitrogen, oxygen and traces of hydrogen have been studied. Intensities of selected spectral transitions of neutral nitrogen and oxygen have been measured. Applying the Boltzmann plot method and using a reliable set of O I transition probabilities of spectral lines, originating from levels considerably spread in excitation energies, the temperatures of arc plasmas have been determined. Line intensities of two N I infrared transitions, originating from doubly excited terms 3p′ 2 F o and 3p′ 2 G have been measured. In order to obtain the corresponding transition probabilities ( A ki ) for these line…

ArgonInfraredchemistry.chemical_elementAtomic and Molecular Physics and OpticsSpectral lineAnalytical Chemistrysymbols.namesakechemistryExcited stateIonizationBoltzmann constantsymbolsAtomic physicsInstrumentationSpectroscopyExcitationHeliumSpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Ellipsometric thickness and coverage of physisorbed layers of Xe, Kr, Ar and N2 on graphite

1990

Multilayer isotherms of Xe, Kr, Ar and N2 physisorbed on graphite (001) have been studied by ellipsometry. It is shown that the model of Dignam and Fedyk provides an excellent basis for the interpretation of the ellipsometric thickness in terms of the coverage and the polarizability of the admolecules. For N2 conclusions concerning the orientation of the molecule are drawn.

ArgonKryptonchemistry.chemical_elementMineralogyNoble gasSurfaces and InterfacesCondensed Matter PhysicsMolecular physicsSurfaces Coatings and FilmsXenonPhysisorptionchemistryEllipsometryPolarizabilityMaterials ChemistryGraphiteSurface Science
researchProduct