Search results for "Argon"
showing 10 items of 250 documents
The effect of different periods of argon deaeration on exhaled breath condensate pH.
2011
Exhaled breath condensate (EBC) pH has been considered as a biomarker of airway inflammation in asthma. However, little information is available on the duration of argon deaeration required to achieve a stable pH in EBC samples.To identify differences in EBC pH after argon deaeration for 2, 4, and 8 min.EBC pH was determined in EBC samples from 48 subjects with allergic rhinitis (11 asthmatics) and 14 healthy volunteers without deaeration and after argon deaeration for 2, 4, and 8 min.The mean (95% CI) pH values obtained from samples analyzed after 4 min [7.66 (7.52-7.80)] and 8 min [7.70 (7.55-7.85)] of argon deaeration were significantly less acidic (p.001) than those identified after 2 m…
Inducible and reversible inhibition of mirna-mediated gene repression in vivo
2021
Although virtually all gene networks are predicted to be controlled by miRNAs, the contribution of this important layer of gene regulation to tissue homeostasis in adult animals remains unclear. Gain and loss-of-function experiments have provided key insights into the specific function of individual miRNAs, but effective genetic tools to study the functional consequences of global inhibition of miRNA activity in vivo are lacking. Here we report the generation and characterization of a genetically engineered mouse strain in which miRNA-mediated gene repression can be reversibly inhibited without affecting miRNA biogenesis or abundance. We demonstrate the usefulness of this strategy by invest…
Determination of ultratrace bismuth in milk samples by atomic fluorescence spectrometry.
2003
Abstract A sensitive procedure was developed for determination of bismuth (Bi) in milk samples by hydride generation atomic fluorescence spectrometry (HG–AFS) after microwave-assisted sample digestion with HNO3 and H2O2. The method provides a sensitivity of 1832 fluorescence units (ng/mL) with a detection limit of 0.01 ng/mL, which corresponds to 20 pg absolute limit of detection, equivalent to 0.50 ng/g in the original sample. Application of the methodology to cow milk samples from the Spanish market showed the presence of Bi at a concentration of 11.8–28.8 ng/g, which compared well with data obtained after dry ashing of samples and with data obtained by inductively coupled plasma–mass spe…
Internal Rotation in Propionic Acid: Near-Infrared-Induced Isomerization in Solid Argon
2005
The conformational system of propionic acid (CH3CH2COOH) is studied in solid argon. It is predicted by the ab initio calculations that this molecule has four stable conformers. These four structures are denoted Tt, Tg+/-, Ct, and Cg+/-, and they differ by the arrangement around the C-O and Calpha-C bonds. The ground-state Tt conformer is the only form present at 8 K after deposition of an argon matrix containing propionic acid. For the CH3CH2COOH and CH3CH2COOD isotopologues, narrow-band excitation of the first hydroxyl stretching overtone of the conformational ground state promotes the Calpha-C and C-O internal rotations producing the Tg+/- and Ct conformers, respectively. A subsequent vib…
Calculated helium-broadened line parameters in the nu4 band of 13CH4
1998
International audience; Helium line-broadening coefficients for transitions in the nu4 band of 13CH4 have been calculated using a semi-classical model. This model is analogous to the one that we have used in a previous study on argon line-broadening coefficients for transitions in the nu3 band of 12CH4. For the present study, over 270 room temperature measurements were considered. The J, symmetry and fine structure dependences of the data are satisfactorily reproduced, although deficiencies of the semi-classical model are evidenced.
Transition probabilities for BrII lines emitted from a wall-stabilized cascade arc
2000
Abstract Absolute transition probabilities of the eleven Br II lines were measured in emission. A plasma created in a wall-stabilized arc at atmospheric pressure in the mixture of argon and bromine vapors was used as the excitation source. The relative transition probabilities were converted to an absolute scale based on a lifetime value measured by the electron impact method. The results were compared with experimental data. Discrepancies have been found to be outside the experimental uncertainties.
Stark effect in some lines of neutral bromine
2002
Abstract This work presents experimental results of profile parameters for prominent lines of neutral bromine, for which serious discrepancies between experimental values of different authors as well as between experimental and calculated values were observed. The observed discrepancies between shock tube and earlier arc experiments are very large. Our results of profile parameters, obtained also in a wall-stabilized arc, show acceptable agreement with the earlier arc measurements. It is obvious, that the shock tube experimental result is out of the range of acceptable inaccuracy and should be remeasured. The theoretical calculations based on different assumptions give also strongly diverge…
Investigation of Hg resonance 184.9nm line profile in a low-pressure mercury–argon discharge
2007
Abstract The line profiles of 184.9 nm Hg resonance line emitted from a Hg low-pressure high-frequency electrodeless discharge lamp, containing Hg 198 isotope, have been measured by means of a Zeeman scanning spectrometer at the mercury cold spot temperature values in the range of 0–23 °C. Two different methods were used to determine the real spectral line profile and to separate the instrument function: (i) solving the ill-posed inverse problem by means of the Tikhonov's regularization method; and (ii) the mathematical modelling by means of a non-linear multi-parameter chi-square fit. The real Hg 184.9 nm spectral line profiles, determined by both methods, are compared. Influence of instru…
Diagnostics of capillary mercury–argon high-frequency electrodeless discharge using line shapes
2005
Abstract The profiles of the 253.7 nm spectral line, emitted from the capillary argon–mercury isotope high-frequency electrodeless discharge, are measured by means of a pressure-scanned Fabry–Perot spectrometer. Spectral line profiles are collected from two lamps at the argon pressure of 2 and 10 Torr, in dependence on the discharge current and Hg vapor densities corresponding to the cold spot temperatures of 25–80 °C. By means of a multi-parameter non-linear line profile fitting procedure of multiple overlapping self-reversed Voigt profiles, the temperature of the radiating atoms and the optical density were estimated. The capillary and spherical discharge conditions were compared. The opt…
Laser driven parametric amplification in the xuv and soft-x-ray spectral range
2011
We present the first experimental realization of a new x-ray laser scheme based on strong-field parametric amplification of high-order harmonic radiation. With a simple semi-classical model, we can identify the most important experimental parameters, the spectral range and the small signal gain in gases. Using a single amplifier stage a small signal gain of 8000 has been obtained in Argon for the spectral range of 40-50 eV, using 350 fs, 7 mJ pulses at 1.05 µm. In Helium, we observed a small signal gain of 280 around 300 eV using 6 fs, 1.5 mJ pulses at 800 nm.