Search results for "Artery"

showing 10 items of 2026 documents

Influence of dopexamine on hemodynamics, intramucosal pH, and regulators of the macrocirculation and microcirculation in patients undergoing abdomina…

2000

Abstract Objective: To investigate whether dopexamine hydrochloride beneficially influences splanchnic perfusion and regulators of the macrocirculation and microcirculation in patients undergoing surgery of the abdominal aorta. Design: Prospective, blinded, and randomized study. Setting: University-affiliated hospital. Participants: Twenty patients undergoing elective abdominal aortic surgery. Interventions: The patients were randomized to one of two groups. In the dopexamine group (DOP, n = 10), dopexamine, 1 μg/kg/min, was started before surgery and continued for 24 hours. In the control group (COG, n = 10), patients received saline solution as placebo. Extensive hemodynamic monitoring wa…

Aortabusiness.industrymedicine.medical_treatmentAbdominal aortaPulmonary artery catheterDopexamineHemodynamicsPlasma renin activityAnesthesiology and Pain Medicinemedicine.arteryAnesthesiamedicineCardiology and Cardiovascular MedicinePulmonary wedge pressurebusinessAbdominal surgerymedicine.drugJournal of Cardiothoracic and Vascular Anesthesia
researchProduct

ANALYSIS OF THE DOSE-RESPONSE CURVE TO SODIUM NITRITE IN ISOLATED RAT AORTA

1978

Aortachemistry.chemical_compoundDose–response relationshipChromatographychemistrymedicine.arterymedicineSodium nitrite
researchProduct

Diagnose und Verlaufsbeurteilung eines intramuralen Hämatoms der Aorta ascendens mit der Magnetresonanztomographie

1998

Aortamedicine.diagnostic_testbusiness.industryArterial diseaseVascular diseaseMagnetic resonance imagingmedicine.diseaseAortic aneurysmAneurysmmedicine.arteryAscending aortamedicineIntramural hemorrhageRadiology Nuclear Medicine and imagingbusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Changes in Adrenoceptors and G-Protein-Coupled Receptor Kinase 2 in <smlcap>L</smlcap>-NAME-Induced Hypertension Compared to Spontaneous …

2014

This work compares the expression of adrenoceptors (ARs) and G-protein-coupled receptor kinase (GRK) 2 (RT-PCR and immunoblotting) and functional responses in conductance (aorta) and resistance vessels (mesenteric resistance arteries; MRA) in two different models of rat hypertension: hypertension induced by chronic treatment with <smlcap>L</smlcap>-NAME (N<sup>G</sup>-nitro-<smlcap>L</smlcap>-arginine methyl-ester) (<smlcap>L</smlcap>-NAME-treated rats; LNHR), and genetically induced hypertension (spontaneously hypertensive rats; SHR). Changes found in the aorta, but not in the MRA, were: (1) a loss of contractile capacity, more evidently in α…

Aortamedicine.medical_specialtyG protein-coupled receptor kinaseContraction (grammar)biologyAdrenergic receptorPhysiologybusiness.industryBeta adrenergic receptor kinaseVasodilationEndocrinologymedicine.arteryIsoprenalineInternal medicinecardiovascular systemmedicinebiology.proteinsense organsmedicine.symptomCardiology and Cardiovascular MedicinebusinessVasoconstrictionmedicine.drugJournal of Vascular Research
researchProduct

Aortic stiffness in patients with early sepsis

2014

Acute and chronic systemic inflammatory conditions are associated with aortic stiffening. Carotid-femoral pulse wave velocity (PWV), a marker of aortic stiffness, increases in patients with inflammatory diseases and independently correlates to levels of C-reactive protein (CRP). The effects of massive inflammatory response in early sepsis on mechanical properties of the aorta have not been investigated. The objective of the current study was to prospectively assess aortic stiffness in patients with early severe sepsis and septic shock and relate it to inflammatory and haemodynamic variables and outcome.

Aortamedicine.medical_specialtyPathologybusiness.industrySeptic shockInflammatory responseHemodynamicsCritical Care and Intensive Care Medicinemedicine.diseaseSepsismedicine.arteryInternal medicinePoster Presentationcardiovascular systemCardiologyMedicineAortic stiffnessIn patientbusinessPulse wave velocityCritical Care
researchProduct

MR-Angiographie peripherer Gefäße mit automatischer Verschiebetisch-Technik bei 1.0 T im Vergleich zur i. a. DSA

1999

PURPOSE Contrast-enhanced (CE) 3D-MR angiography of peripheral arteries was performed in 8 patients with peripheral arterial occlusive disease by applying a new tracking technique on a 1.0 T system (Magnetom Harmony, Siemens). The studies were compared with intra-arterial digital angiography as gold standard. MATERIALS AND METHODS Imaging of the distal aorta, pelvis, upper and lower limb arteries was accomplished with a Flash-3D-sequence (TR/TE = 6.2/3.2 ms) within 26 s acquisition time of each region after a single bolus of 30 ml contrast agent. Individual circulation time was determined by a test bolus before each examination. RESULTS 112 vessel segments were evaluated. MR angiography ach…

Aortamedicine.medical_specialtymedicine.diagnostic_testbusiness.industryVascular diseaseMr angiographyGold standard (test)medicine.diseasePeripheralStenosismedicine.anatomical_structuremedicine.arteryAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessArteryRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Helical computed tomographyangiography: Technical considerations and clinical applications

1997

Abstract A combination of volume acquisition techniques (helical CT), dedicated protocolsfor bolus injections of contrast medium, and postprocessing modalities have paved the way for computed tomography (CT) angiography. To obtain optimum results the collimation must be adapted to the vascular territory of interest, and the reconstruction of overlapping source images from the volume data set is advantageous for further postprocessing. Strong intravascular opacification is indispensable for the evaluation of vascular abnormalities and pathology and is also helpful for image postprocessing, where different modalities can be applied: multiplanar reconstruction, maximum intensity projection, se…

Aortamedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.diseaseRenal artery stenosisPulmonary embolismStenosisContrast mediummedicine.arteryMaximum intensity projectionOcclusionAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessRadiography
researchProduct

Kontrastverstärkte MR-Angiographie abdomineller Gefäßean einem 1.0 T-System*

2000

Purpose To evaluate the efficacy of breath-hold, three-dimensional, contrast-enhanced magnetic resonance angiography with a 1.0 T system for imaging the abdominal vessels in comparison to conventional arteriography (CA). Methods The abdominal aorta and visceral arteries were studied in 54 patients (60 examinations) on a 1.0 T scanner using an ultrafast gadolinium-enhanced gradient-echo sequence with the following parameters: TR/TE = 3.8/1.4 ms, flip angel 25 degrees, matrix 198 x 256, field 380-420 mm, pixel size 1.9 x 1.48 mm2, slice thickness 1.5-2.5 mm, acquisition time 22-26 sec. Individual circulation times were determined by a test bolus before each MR angiography. Conventional arteri…

Aortamedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentAbdominal aortaStentDigital subtraction angiographyMagnetic resonance angiographymedicine.anatomical_structuremedicine.arteryAngiographymedicineAbdomenRadiology Nuclear Medicine and imagingRadiologybusinessBlood vesselRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Early results of a low-profile stent-graft for thoracic endovascular aortic repair

2020

Purpose To assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies. Methods A retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019. Results 23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was a…

Aortic archElephant trunksEndoleakCardiovascular ProceduresPhysiologymedicine.medical_treatmentVascular SurgeryAorta ThoracicPathology and Laboratory MedicineNervous SystemPostoperative ComplicationsMedicine and Health SciencesLeukocytosisAortaCerebrospinal FluidAged 80 and overMultidisciplinaryQRArteriesMiddle AgedBody FluidsTreatment OutcomeMedicineEngineering and TechnologyFemaleStentsmedicine.symptomAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyScienceAortic DiseasesBioengineeringSurgical and Invasive Medical ProceduresBlood Vessel Prosthesis Implantationmedicine.arterymedicineHumansAortic ruptureAgedRetrospective StudiesAortabusiness.industryStentBiology and Life SciencesVascular surgerySurgeryAppositionSurgical RepairAnatomical PathologyCardiovascular AnatomyBlood VesselsMedical Devices and EquipmentbusinessPLoS ONE
researchProduct

Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…

2012

Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…

Aortic archEndoleakMedizinAnastomotic LeakAorta ThoracicChest painPatient Care PlanningAortic aneurysmPostoperative ComplicationsIntraoperative ComplicationsBrain DiseasesEndovascular ProceduresAngiographyEquipment DesignGeneral MedicineTreatment OutcomeCardiothoracic surgeryDescending aortacardiovascular systemCardiologyStentsmedicine.symptomCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyConsensusAortic DiseasesPerioperative CareSpinal Cord DiseasesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryInternal medicineMonitoring IntraoperativemedicineHumansAortaAortic Aneurysm Thoracicbusiness.industryContraindicationsPatient SelectionVascular System Injuriesmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic DissectionSurgerybusinessTomography X-Ray ComputedEchocardiography TransesophagealEuropean Journal of Cardio-Thoracic Surgery
researchProduct