Search results for "Artifact"
showing 10 items of 193 documents
The effects of linearly increasing flip angles on 3D inflow MR angiography
1994
As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…
Fluoride-induced precipitates on enamel surface and subsurface areas visualised by electron microscopy and confocal laser scanning microscopy
1997
The present study examined the enamel surface after in vitro topical treatments with a neutral 2% NaF solution. For minimising the risk of artefacts, samples were inspected without pre-treatment as fresh, naturally wet specimens by complementary techniques: variable pressure electron microscopy (VP-SEM) and confocal laser scanning microscopy (CLSM). VP-SEM provided information on the surface morphology, whereas CLSM allowed non-destructive visualisation of subsurface areas. Neutral NaF solutions induced globular precipitates on the enamel surfaces. If the globules formed may be described as "calcium fluoride like material", the additional information of this experiment is that, after intera…
Removing striping artifacts in light-sheet fluorescence microscopy: a review
2022
Abstract In recent years, light-sheet fluorescence microscopy (LSFM) has found a broad application for imaging of diverse biological samples, ranging from sub-cellular structures to whole animals, both in-vivo and ex-vivo, owing to its many advantages relative to point-scanning methods. By providing the selective illumination of sample single planes, LSFM achieves an intrinsic optical sectioning and direct 2D image acquisition, with low out-of-focus fluorescence background, sample photo-damage and photo-bleaching. On the other hand, such an illumination scheme is prone to light absorption or scattering effects, which lead to uneven illumination and striping artifacts in the images, oriented…
Dynamic landscapes, artifact taphonomy, and landuse modeling in the western Mediterranean
2002
The Polop Alto valley, in eastern Spain, is characteristic of many Mediterranean landscapes. It has been sporadically reoccupied over the course of at least 80 kyr. Its landforms have undergone various geomorphic processes resulting from late Quaternary environmental fluctuations. During the Holocene, the valley has been modified by millennia of extensive land clearance, cultivation, and terracing. As a result, the evidence for human activity and landuse is a cumulative, but discontiguous palimpsest of the most durable behavioral residues—primarily stone and ceramic artifacts—whose distributions have been affected by diverse natural and cultural formation processes. Human occupation of the …
Teacher response pursuits in whole class post-task discussions
2020
This paper explores teacher elicitation practices following a perceived absence of a response to an initial inquiry. Specifically, we focus on whole class post-task discussions where a teacher pursues responses in post-first position following students’ non-uptake, and thus makes her orientation toward the expectation of a response publicly available. The data for this study come from 30 h of video-recorded classroom interactions in an English as a medium of instruction university in Turkey. Using Conversation Analysis, this study demonstrates that when confronted with a non-response to her initial elicitation in whole class interaction, in addition to drawing on interactional resources (e.…
Reduction of spherical-aberration impact in microscopy by wavefront coding
2009
In modern high-NA optical scanning instruments, like scanning microscopes, the refractive-index mismatch between the sample and the immersion medium introduces a significant amount of spherical aberration when imaging deep inside the specimen, spreading out the impulse response. Since such aberration depends on the focalization depth, it is not possible to achieve a static global compensation for the whole 3D sample in scanning microscopy. Therefore a depth-variant impulse response is generated. Consequently, the design of pupil elements that increase the tolerance to this aberration is of great interest. In this paper we report a hybrid technique that provides a focal spot that remains alm…
A human post-mortem brain model for the standardization of multi-centre MRI studies
2015
Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic t…
Effects of static and dynamic perturbations on isotropic hyperfine coupling constants in some quinone radicals.
2004
The effects of solvent dielectric response on the isotropic hyperfine coupling constants of the 1,4-benzoquinone, 1,4-naphthoquinone and 9,10-anthraquinone anions and 1,4-naphthalenediol cation radicals were studied by electron spin resonance (ESR) spectroscopy and by the theoretical density functional method within the polarizable continuum model. Experimental results demonstrate that the isotropic hyperfine coupling constants can be obtained with high accuracy and that the effects of solvent impurities can be minimized by careful sample preparation. The results obtained correlate well with theoretical predictions from density functional theory calculations. For 1,4-naphthalenediol both th…
The Low Barrier Hydrogen Bond in the Photoactive Yellow Protein: A Vacuum Artifact Absent in the Crystal and Solution
2016
Journal of the American Chemical Society 138(51), 16620 - 16631 (2016). doi:10.1021/jacs.6b05609
Adaptive independent vector analysis for multi-subject complex-valued fMRI data.
2017
Abstract Background Complex-valued fMRI data can provide additional insights beyond magnitude-only data. However, independent vector analysis (IVA), which has exhibited great potential for group analysis of magnitude-only fMRI data, has rarely been applied to complex-valued fMRI data. The main challenges in this application include the extremely noisy nature and large variability of the source component vector (SCV) distribution. New method To address these challenges, we propose an adaptive fixed-point IVA algorithm for analyzing multiple-subject complex-valued fMRI data. We exploited a multivariate generalized Gaussian distribution (MGGD)- based nonlinear function to match varying SCV dis…