Search results for "Artifacts"

showing 10 items of 105 documents

Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data.

2010

Objective Partial volume effects caused by limited spatial resolution of conventional positron emission tomography (PET) scanners result in an underestimation of the activity concentration in small tumours. The aim of the study was to evaluate the feasibility of small animal tumour imaging with the clinical PET scanner ECAT EXACT after partial volume correction based on MRI calculations. The same tumour model was examined additionally with the small animal PET system, microPET focus 120. Methods Before the ECAT EXACT studies recovery coefficients for different sphere volumes were generated with phantom experiments. For the following in-vivo study DS-sarcoma cells were implanted on both hind…

MaleScannerFocus (geometry)Partial volumeImaging phantomRats Sprague-DawleySmall animalNeoplasmsmedicineAnimalsRadiology Nuclear Medicine and imagingGamma countermedicine.diagnostic_testbusiness.industryPhantoms ImagingMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingRatsTumor BurdenPositron emission tomographyPositron-Emission TomographyLinear ModelsFeasibility StudiesNuclear medicinebusinessArtifactsNuclear medicine communications
researchProduct

Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challenge

2014

Contains fulltext : 137969.pdf (Publisher’s version ) (Open Access) Prostate MRI image segmentation has been an area of intense research due to the increased use of MRI as a modality for the clinical workup of prostate cancer. Segmentation is useful for various tasks, e.g. to accurately localize prostate boundaries for radiotherapy or to initialize multi-modal registration algorithms. In the past, it has been difficult for research groups to evaluate prostate segmentation algorithms on multi-center, multi-vendor and multi-protocol data. Especially because we are dealing with MR images, image appearance, resolution and the presence of artifacts are affected by differences in scanners and/or …

MaleScannerObserver (quantum physics)Computer scienceHealth InformaticsSensitivity and SpecificityArticleProstate cancerSegmentationImaging Three-DimensionalRobustness (computer science)Image Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationChallengeProtocol (science)Modality (human–computer interaction)Radiological and Ultrasound TechnologyProstateProstatic NeoplasmsReproducibility of ResultsReference Standardsmedicine.diseaseImage EnhancementComputer Graphics and Computer-Aided DesignMagnetic Resonance ImagingActive appearance modelUrological cancers Radboud Institute for Health Sciences [Radboudumc 15]Computer Vision and Pattern RecognitionArtifactsAlgorithmAlgorithmsRare cancers Radboud Institute for Health Sciences [Radboudumc 9]MRI
researchProduct

Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography.

2005

PURPOSE: To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIALS AND METHODS: One hundred patients (88 males; 59+/-11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/ml at 4 ml/s and …

MaleStatistical Female *Heart Rate Humans Male Middle Aged Retrospective Studies Sensitivity and Specificity TomographyContrast MediaCoronary DiseaseCoronary Artery DiseaseCoronary AngiographySensitivity and SpecificityHeart RateTriiodobenzoic AcidsHumanscoronary artery stenosisAgedRetrospective StudiesBody WeightCoronary StenosisCalcinosisMiddle AgedAged Artifacts Body Weight Calcinosis/*radiography Contrast Media Coronary Angiography/*methods Coronary Artery Disease/radiography Coronary Disease/*radiography Coronary Stenosis/radiography Data Interpretation; Statistical Female *Heart Rate Humans Male Middle Aged Retrospective Studies Sensitivity and Specificity Tomography; X-Ray Computed/*methods Triiodobenzoic Acids/administration & dosage/diagnostic useX-Ray Computed/*methods Triiodobenzoic Acids/administration & dosage/diagnostic useData Interpretation StatisticalAged Artifacts Body Weight Calcinosis/*radiography Contrast Media Coronary Angiography/*methods Coronary Artery Disease/radiography Coronary Disease/*radiography Coronary Stenosis/radiography Data InterpretationFemalemultislice computed tomography (MSCT)ArtifactsTomography X-Ray Computedcoronary artery stenosis; multislice computed tomography (MSCT)
researchProduct

Cryopreservation of prostate cancer tissue during routine processing of fresh unfixed prostatectomy specimen: demonstration and validation of a new t…

2008

BACKGROUND Most molecular techniques currently require fresh frozen tumor tissue, which in the case of prostatectomy specimen is a challenge to obtain for a variety of intrinsic reasons. Prostate cancers are usually located in the organ periphery and hence meticulous attention has to be paid to the relation between the tumor and the surgical margin. In this article we describe a new technique that allows to obtain fresh frozen tumor material in rather large quantities and without jeopardizing diagnostic accuracy. METHOD An inner triangle, representing roughly 50% of the entire prostate tissue, is removed from native prostatectomy specimen and cryopreserved, leaving the periphery of the orga…

MaleSurgical marginmedicine.medical_specialtyUrologymedicine.medical_treatmentCryopreservationProstate cancerProstatemedicineCarcinomaHumansCryopreservationProstatectomybusiness.industryProstatectomyProstatic NeoplasmsReproducibility of ResultsHistologymedicine.diseaseSurgerymedicine.anatomical_structureOncologyTissue bankRadiologyArtifactsbusinessThe Prostate
researchProduct

TMS-evoked long-lasting artefacts: A new adaptive algorithm for EEG signal correction

2017

Abstract Objective During EEG the discharge of TMS generates a long-lasting decay artefact (DA) that makes the analysis of TMS-evoked potentials (TEPs) difficult. Our aim was twofold: (1) to describe how the DA affects the recorded EEG and (2) to develop a new adaptive detrend algorithm (ADA) able to correct the DA. Methods We performed two experiments testing 50 healthy volunteers. In experiment 1, we tested the efficacy of ADA by comparing it with two commonly-used independent component analysis (ICA) algorithms. In experiment 2, we further investigated the efficiency of ADA and the impact of the DA evoked from TMS over frontal, motor and parietal areas. Results Our results demonstrated t…

MaleTime Factorsmedicine.medical_treatmentElectroencephalographySignal0302 clinical medicineSignal correctionDetrendEEGAdaptive algorithmmedicine.diagnostic_test05 social sciencesElectroencephalographyTranscranial Magnetic StimulationSensory SystemsAlgorithmNeurologyArtefact; Detrend; EEG; ICA; TMS; Sensory Systems; Neurology; Neurology (clinical); Physiology (medical)ArtifactFemalePrimary motor cortexArtifactsPsychologyAlgorithmsHumanAdultTime Factor050105 experimental psychologyNOYoung Adult03 medical and health sciencesPhysiology (medical)medicineHumansMiddle frontal gyrus0501 psychology and cognitive sciencesICAArtefactSettore M-PSI/02 - Psicobiologia E Psicologia Fisiologicabusiness.industryPattern recognitionIndependent component analysisTranscranial magnetic stimulationTMSNeurology (clinical)Artificial intelligenceSensory SystembusinessNeuroscience030217 neurology & neurosurgeryClinical Neurophysiology
researchProduct

Prognostic implications of dipyridamole cardiac MR imaging: a prospective multicenter registry

2011

Purpose: To evaluate dipyridamole cardiac magnetic resonance (MR) imaging in the prediction of major events (MEs) in patients with ischemic chest pain in a large multicenter registry. Materials and Methods: Institutional ethics committee approval and written informed consent were obtained. A total of 1722 patients who were undergoing cardiac MR imaging for chest pain were included. Wall motion abnormalities (WMAs) at rest, hyperemia perfusion defect (PD), late gadolinium enhancement (LGE), and inducible WMA were analyzed (abnormal if more than one abnormal segment was seen) with the 17-segment model. A cardiac MR categorization was created: category 1, no PD, LGE, or inducible WMA; category…

MaleVasodilator AgentsMyocardial InfarctionMyocardial IschemiaCardiovascular magnetic-resonanceContrast Medialaw.inventionCoronary artery diseaseCoronary-artery-diseaseRandomized controlled triallawMyocardial RevascularizationProspective StudiesRegistriesMyocardial infarctionDipyridamoleMiddle AgedPrognosisManagementDipyridamoleCardiologyFemaleRadiologyArtifactsmedicine.drugChest Painmedicine.medical_specialtyMagnetic Resonance Imaging CineIschemic cascadeStatistics NonparametricAssociationTECNOLOGIA ELECTRONICAPredictive Value of TestsInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingWall motionAgedProportional Hazards ModelsChi-Square DistributionStress perfusionbusiness.industryReproducibility of ResultsIschemic cascademedicine.diseaseMr imagingMyocardial-infarctionDysfunctionCase-Control StudiesReperfusionIschemic chest painbusiness
researchProduct

The effects of linearly increasing flip angles on 3D inflow MR angiography

1994

As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…

Materials scienceInflowsymbols.namesakeNuclear magnetic resonanceHumansPopliteal ArteryRadiology Nuclear Medicine and imagingSaturation (magnetic)Fourier AnalysisModels CardiovascularMr angiographyReproducibility of ResultsPulse durationRangingArteriesImage EnhancementMagnetic Resonance ImagingComputational physicsTibial ArteriesFourier transformFibulaRegional Blood FlowBlood CirculationsymbolsSlabBlood VesselsArtifactsAlgorithmsBlood Flow VelocityExcitationMagnetic Resonance in Medicine
researchProduct

Fluoride-induced precipitates on enamel surface and subsurface areas visualised by electron microscopy and confocal laser scanning microscopy

1997

The present study examined the enamel surface after in vitro topical treatments with a neutral 2% NaF solution. For minimising the risk of artefacts, samples were inspected without pre-treatment as fresh, naturally wet specimens by complementary techniques: variable pressure electron microscopy (VP-SEM) and confocal laser scanning microscopy (CLSM). VP-SEM provided information on the surface morphology, whereas CLSM allowed non-destructive visualisation of subsurface areas. Neutral NaF solutions induced globular precipitates on the enamel surfaces. If the globules formed may be described as "calcium fluoride like material", the additional information of this experiment is that, after intera…

Materials scienceMorphology (linguistics)AdolescentCausticsPotassium CompoundsConfocalAnalytical chemistrychemistry.chemical_elementlaw.inventionchemistry.chemical_compoundlawSodium fluorideHydroxidesChemical PrecipitationHumansFluorides TopicalChildDental EnamelTooth DemineralizationGeneral DentistryMicroscopy ConfocalEnamel paintSodiumtechnology industry and agricultureFluorineCariostatic Agentsbody regionsCalcium Fluoridechemistryvisual_artMicroscopy Electron ScanningFluorinevisual_art.visual_art_mediumSodium FluorideCalciumCrystalliteElectron microscopeArtifactsCrystallizationFluorideElectron Probe MicroanalysisEuropean Journal of Oral Sciences
researchProduct

Removing striping artifacts in light-sheet fluorescence microscopy: a review

2022

Abstract In recent years, light-sheet fluorescence microscopy (LSFM) has found a broad application for imaging of diverse biological samples, ranging from sub-cellular structures to whole animals, both in-vivo and ex-vivo, owing to its many advantages relative to point-scanning methods. By providing the selective illumination of sample single planes, LSFM achieves an intrinsic optical sectioning and direct 2D image acquisition, with low out-of-focus fluorescence background, sample photo-damage and photo-bleaching. On the other hand, such an illumination scheme is prone to light absorption or scattering effects, which lead to uneven illumination and striping artifacts in the images, oriented…

Materials scienceOptical sectioningBiophysicsBrain imaging01 natural sciences010309 optics03 medical and health sciencesOptics0103 physical sciencesFluorescence microscopeAnimalsMolecular Biology030304 developmental biology0303 health sciencesLight-sheet microscopyScatteringbusiness.industryRangingSample (graphics)FluorescenceMicroscopy FluorescenceLight sheet fluorescence microscopy3D microscopyStripingData striping3D microscopy; Brain imaging; Light-sheet microscopy; StripingArtifactsbusinessProgress in Biophysics and Molecular Biology
researchProduct

Reduction of spherical-aberration impact in microscopy by wavefront coding

2009

In modern high-NA optical scanning instruments, like scanning microscopes, the refractive-index mismatch between the sample and the immersion medium introduces a significant amount of spherical aberration when imaging deep inside the specimen, spreading out the impulse response. Since such aberration depends on the focalization depth, it is not possible to achieve a static global compensation for the whole 3D sample in scanning microscopy. Therefore a depth-variant impulse response is generated. Consequently, the design of pupil elements that increase the tolerance to this aberration is of great interest. In this paper we report a hybrid technique that provides a focal spot that remains alm…

MicroscopyMaterials scienceMicroscopebusiness.industryImage EnhancementAtomic and Molecular Physics and Opticslaw.inventionSpherical aberrationOpticsOptical microscopelawImage Interpretation Computer-AssistedDigital image processingMicroscopyDeconvolutionArtifactsbusinessAlgorithmsImpulse responseWavefront codingOptics Express
researchProduct