Search results for "Athena"
showing 10 items of 30 documents
Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution
2018
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining…
The performance of the ATHENA X-ray Integral Field Unit
2018
The X-ray Integral Field Unit (X-IFU) is a next generation microcalorimeter planned for launch onboard the Athena observatory. Operating a matrix of 3840 superconducting Transition Edge Sensors at 90 mK, it will provide unprecedented spectro-imaging capabilities (2.5 eV resolution, for a field of view of 5') in the soft X-ray band (0.2 up to 12 keV), enabling breakthrough science. The definition of the instrument evolved along the phase A study and we present here an overview of its predicted performances and their modeling, illustrating how the design of the X-IFU meets its top-level scientific requirements. This article notably covers the energy resolution, count-rate capability, quantum …
The Wide Field Imager instrument for Athena
2017
ESA's next large X-ray mission ATHENA is designed to address the Cosmic Vision science theme 'The Hot and Energetic Universe'. It will provide answers to the two key astrophysical questions how does ordinary matter assemble into the large-scale structures we see today and how do black holes grow and shape the Universe. The ATHENA spacecraft will be equipped with two focal plane cameras, a Wide Field Imager (WFI) and an X-ray Integral Field Unit (X-IFU). The WFI instrument is optimized for state-of-The-Art resolution spectroscopy over a large field of view of 40 amin x 40 amin and high count rates up to and beyond 1 Crab source intensity. The cryogenic X-IFU camera is designed for high-spect…
Deformation analysis of ATHENA test filters made of plastic thin films supported by a mesh under differential static pressure
2019
Within ESA Cosmic Vision 2015-2025 Science Program, ATHENA was selected to be a Large-class high energy astrophysics space mission. The observatory will be equipped with two interchangeable focal plane detectors named X-Ray Integral Field Unit (X-IFU) and Wide Field Imager (WFI). In order to optimally exploit the detector sensitivity, X-ray transparent filters are required. Such filters need to be extremely thin to maximize the X-ray transparency, that is, no more than a few tens of nm, still they must be able to sustain the severe stresses experienced during launch. Partially representative test filters were made with a thin polypropylene film, coated with Ti, and supported by a thin highl…
Brief an Garlieb H. Merkel
1799
Ms. 930a, Nr. 8, Bl. 22r-23v Böttiger, Karl August. Brief an Garlieb H. Merkel, Weimar, d[en] 13. November 1797 Autora rokraksts / Autograph, vācu, angļu un latīņu val. / Deutsch, Englisch und Latein [4] lpp. / S. Attēlu numuri / Bildnummern: 930a-008-1 – 930a-008-4 Der Verfasser nennt in diesem inhaltsreichen Brief zahlreiche Namen und hält nicht nur die Verbindung mit Merkel, die aus dessen erstem Aufenthalt in Weimar resultierte, aufrecht, sondern gibt ihm weitere Hinweise und Empfehlung für seinen weiteren Aufenthalt in Dänemark. So rät er zur Übersetzung dreier Romane aus dem Englischen, darunter Jane Wests „A gossip's story“ (London 1796). Ferner bittet der Verfasser Merkel um Gefälli…
Surface investigation and aluminum oxide estimation on test filters for the ATHENA X-IFU and WFI detectors
2016
The ATHENA mission provides the demanded capabilities to address the ESA science theme "Hot and Energetic Universe". Two complementary instruments are foreseen: the X-IFU (X-ray Integral Field Unit) and WFI (Wide Field Imager). Both the instruments require filters to avoid that the IR radiation heats the X-IFU cryogenic detector and to protect the WFI detector from UV photons. Previous experience on XMM filters recommends to employ bilayer membrane consisting of aluminum deposited on polyimide. In this work, we use the X-ray Photoelectron Spectroscopy (XPS) to quantify the native aluminum oxide thickness that affects the spectral properties of the filter. The estimation of the oxide thickne…
Preliminary Mechanical Characterization of Thermal Filters for the X-IFU Instrument on Athena
2018
The X-ray Integral Field Unit (X-IFU) is one of the two instruments of the Athena astrophysics space mission approved by ESA in the Cosmic Vision Science Program. The X-IFU consists of a large array of TES microcalorimeters that will operate at ~ 50 mK inside a sophisticated cryostat. A set of thin filters, highly transparent to X-rays, will be mounted on the cryostat thermal shields in order to attenuate the IR radiative load, to attenuate RF electromagnetic interferences, and to protect the detector from contamination. In this paper, we present the current thermal filters design, describe the filter samples developed/procured so far, and present preliminary results from the ongoing charac…
The x-ray microcalorimeter spectrometer onboard Athena
2012
Trabajo presentado a la conferencia: "Space Telescopes and Instrumentation: Ultraviolet to Gamma Ray" celebrada en Amsterdam (Holanda) el 1 de julio de 2012.-- et al.
Development of the wide field imager for Athena
2015
The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 arcmin x 40 arcmin together with excellent count-rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 6 keV will be <= 150 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec of…
Preliminary assessment of the ATHENA/WFI non-X-ray background
2017
We present a preliminary assessment of the non-X-ray background for the WFI on board ATHENA conducted at IAAT in the context of the collaborative background and radiation damage working group activities. Our main result is that in the baseline configuration originally assumed for the camera the requirement on the level of non-X-ray background could not be met. In light of the results of Geant4 simulations we propose and discuss a possible optimization of the camera design and pinpoint some open issues to be addressed in the next phase of investigation. One of these concerns the possible contribution to the non-X-ray background from soft protons and ions funneled to the focal plane through t…