Search results for "Atomi"

showing 10 items of 28717 documents

Simulation and optimization of the implantation of holmium atoms into metallic magnetic microcalorimeters for neutrino mass determination experiments

2017

Abstract Several novel experiments designed to investigate the electron neutrino mass in the sub-eV region are based on the calorimetric measurement of the 163Ho electron capture spectrum. For this the 163Ho source, with a required activity of the order of 1 to 100 Bq , needs to be enclosed in the detector, having a volume smaller than 10 − 3 mm 3 . Ion implantation is presently considered to be the most reliable method to enclose this source in the detector homogeneously distributed in a well defined volume. We have investigated the distribution of implanted holmium ions in different target materials and for different implantation energies by means of Monte Carlo simulations based on the S…

010302 applied physicsPhysicsNuclear and High Energy PhysicsElectron captureMonte Carlo methodDetectorchemistry.chemical_element01 natural sciencesIonIon implantationchemistry0103 physical sciencesAtomic physicsNeutrino010306 general physicsHolmiumInstrumentationElectron neutrinoNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Hot-cavity studies for the Resonance Ionization Laser Ion Source

2016

International audience; The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency an…

010302 applied physicsPhysicsNuclear and High Energy PhysicsIon beamTitanium sapphire laser[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Ion gun7. Clean energy01 natural sciencesIon sourceAtmospheric-pressure laser ionizationHot cavityRadioactive Ion BeamWork function materialResonant Ionization Laser Ion SourceIon beam depositionIonization0103 physical sciencesPhysics::Accelerator PhysicsThermal emittanceAtomic physicsBeam emittance010306 general physicsInstrumentation
researchProduct

Radiation emission at channeling of electrons in a strained layer undulator crystal

2013

Abstract Experiments have been performed at the Mainz Microtron MAMI to explore the radiation emission spectra from a crystalline undulator at electron beam energies of 270 and 855 MeV. The epitaxially grown graded composition strained layer Si 1 - x Ge x undulator had 4-period with a period length λ u = 9.9 μ m . Spectra taken at the beam energy of 270 MeV at channeling in the undulating (110) planes exhibit a broad excess yield around the theoretically expected photon energies of 0.069 MeV, as compared with a flat silicon reference crystal. Model calculations on the basis of synchrotron-like radiation emission from finite single arc elements, taking into account also coherence effects, su…

010302 applied physicsPhysicsNuclear and High Energy PhysicsPhotonSiliconchemistry.chemical_elementElectronUndulator01 natural sciencesSpectral lineCrystalchemistry0103 physical sciencesCathode rayPhysics::Accelerator PhysicsAtomic physicsNuclear Experiment010306 general physicsInstrumentationMicrotronNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

The effect of plasma electrode collar structure on the performance of the JYFL 14GHz electron cyclotron resonance ion source

2013

Abstract The influence of a so-called collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) has been studied experimentally at the Department of Physics, University of Jyvaskyla (JYFL). The collar is a cylindrical structure extruding inwards from the plasma electrode. The collar length was varied between 5 and 60 mm. For some ion species a moderate performance improvement was achieved in terms of extracted beam current and transverse emittance up to 30 mm collar length. Longer collars resulted in a substantial performance decrease. Different collar materials, i.e. nonmagnetic stainless steel, aluminum and Al 2 O 3 , and a wide range of ion sp…

010302 applied physicsPhysicsNuclear and High Energy Physicsta114Plasma01 natural sciences7. Clean energyElectron cyclotron resonanceIon source010305 fluids & plasmasCollarIon0103 physical sciencesElectrodeThermal emittanceddc:530Atomic physicsInstrumentationBeam (structure)
researchProduct

Estimation of Photon Flux of the Oxygen Lyman-alpha Line Emitted from the W7-X Plasmas

2020

The low-Z impurities of the magnetic confined fusion plasmas can provide important information about the wall condition and plasma–wall interactions. In order to accomplish this aim, a special spectrometer called “C/O Monitor” was designed for the W7-X experiment. This system is dedicated to measure Lyman-α transitions of four low-Z impurities: carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm) and boron (4.9 nm). It is a high throughput and high time resolution spectrometer which allows to measure the line intensities evolution of indicated elements including information of the background (continuum). The designed spectrometer consists of two vacuum chambers positioned nearly horizontally…

010302 applied physicsPhysicsPhoton fluxGeneral Physics and Astronomychemistry.chemical_element02 engineering and technologyPlasma021001 nanoscience & nanotechnology01 natural sciencesOxygenchemistry0103 physical sciencesAtomic physics0210 nano-technologyLine (formation)
researchProduct

Broadband microwave emission spectrum associated with kinetic instabilities in minimum-B ECR plasmas

2017

Plasmas of electron cyclotron resonance ion sources (ECRISs) are prone to kinetic instabilities due to the resonant heating mechanism resulting in anisotropic electron velocity distribution. Frequently observed periodic oscillations of extracted ion beam current in the case of high plasma heating power and/or strong magnetic field have been proven to be caused by cyclotrontype instabilities leading to a notable reduction and temporal variation of highly charged ion production. Thus, investigations of such instabilities and techniques for their suppression have become important topics in ECRIS research. The microwave emission caused by the instabilities contains information on the electron e…

010302 applied physicsPhysicsRange (particle radiation)microwave sourcesIon sourcesIon beamta114Highly charged ionPlasmaAstrophysics::Cosmology and Extragalactic Astrophysicsplasma instabilitiesmagnetic fieldsCondensed Matter PhysicsPlasma oscillationmagneettikentät01 natural sciences7. Clean energyElectron cyclotron resonanceIonPhysics::Plasma Physicsmicrowave spectra0103 physical sciencesAtomic physics010306 general physicsMicrowave
researchProduct

Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma

2017

A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…

010302 applied physicsPhysicsRange (particle radiation)plasma sourcesta114plasma diagnosticsPlasmaCondensed Matter PhysicsMass spectrometry01 natural sciences7. Clean energyIon source010305 fluids & plasmasIonplasma dynamicsPhysics::Plasma Physics0103 physical sciencesThermal emittancePlasma diagnosticsionAtomic physicsMicrowaveplasma sheathsPhysics of Plasmas
researchProduct

High efficiency resonance ionization of palladium with Ti:sapphire lasers

2016

This work presents the development and testing of highly efficient excitation schemes for resonance ionization of palladium. To achieve the highest ionization efficiencies, a high-power, high repetition rate Ti:sapphire laser system was used and 2-step, 3-step and 4-step schemes were investigated and compared. Starting from different excited steps, the frequencies of the final ionization steps were tuned across the full accessible spectral range of the laser system, revealing several autoionizing Rydberg series, which converge towards the energetically higher lying state of the Pd+ ion ground state configuration. Through proper choice of these excitation steps, we developed a highly efficie…

010302 applied physicsPhysicsResonanceCondensed Matter PhysicsLaser01 natural sciencesAtomic and Molecular Physics and OpticsIon sourcelaw.inventionIonlawIonizationExcited state0103 physical sciencesPhysics::Atomic PhysicsAtomic physics010306 general physicsGround stateExcitationJournal of Physics B: Atomic, Molecular and Optical Physics
researchProduct

Measurements of the energy distribution of electrons lost from the minimum B-field -- the effect of instabilities and two-frequency heating

2020

Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of EED in unstable mode of plasma confinement, i.e. in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences bet…

010302 applied physicsPhysicsResonanceFOS: Physical sciencesPlasmaElectronhiukkaskiihdyttimetplasmafysiikka7. Clean energy01 natural sciencesPhysics - Plasma PhysicsElectron cyclotron resonanceIon source010305 fluids & plasmasMagnetic fieldIonPlasma Physics (physics.plasm-ph)Magnetic trap0103 physical sciencesAtomic physicsInstrumentation
researchProduct

Effects of magnetic configuration on hot electrons in a minimum-B ECR plasma

2020

International audience; To investigate the hot electron population and the appearance of kinetic instabilities in highly charged electron cyclotron resonance ion source (ECRIS), the axially emitted bremsstrahlung spectra and microwave bursts emitted from ECRIS plasma were synchronously measured on SECRAL-II (Superconducting ECR ion source with Advanced design in Lanzhou No. II) ion source with various magnetic field configurations. The experimental results show that when the ratio of the minimum field to the resonance field (i.e. Bmin/Becr ) is less than ~0.8, the bremsstrahlung spectral temperature Ts increases linearly with the Bmin/Becr –ratio when the injection, extraction and radial mi…

010302 applied physicsPhysics[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonanceBremsstrahlungResonancePlasmaCondensed Matter Physics01 natural sciencesElectromagnetic radiationElectron cyclotron resonance010305 fluids & plasmasMagnetic fieldNuclear Energy and Engineering0103 physical sciencesAtomic physicsMicrowave
researchProduct