Search results for "Audi"
showing 10 items of 3302 documents
Key issues in decomposing fMRI during naturalistic and continuous music experience with independent component analysis
2014
Background: Independent component analysis (ICA) has been often used to decompose fMRI data mostly for the resting-state, block and event-related designs due to its outstanding advantage. For fMRI data during free-listening experiences, only a few exploratory studies applied ICA.New method: For processing the fMRI data elicited by 512-s modern tango, a FFT based band-pass filter was used to further pre-process the fMRI data to remove sources of no interest and noise. Then, a fast model order selection method was applied to estimate the number of sources. Next, both individual ICA and group ICA were performed. Subsequently, ICA components whose temporal courses were significantly correlated …
Neural correlates of antinociception in borderline personality disorder.
2006
Context A characteristic feature of borderline personality disorder (BPD) is self-injurious behavior in conjunction with stress-induced reduction of pain perception. Reduced pain sensitivity has been experimentally confirmed in patients with BPD, but the neural correlates of antinociceptive mechanisms in BPD are unknown. We predicted that heat stimuli in patients with BPD would activate brain areas concerned with cognitive and emotional evaluation of pain. Objective To assess the psychophysical properties and neural correlates of altered pain processing in patients with BPD. Design Case-control study. Setting A university hospital. Participants Twelve women with BPD and self-injurious behav…
Differential nociceptive deficits in patients with borderline personality disorder and self-injurious behavior: laser-evoked potentials, spatial disc…
2003
Approximately 70-80% of women meeting criteria for borderline personality disorder (BPD) report attenuated pain perception or analgesia during non-suicidal, intentional self-mutilation. The aim of this study was to use laser-evoked potentials (LEPs) and psychophysical methods to differentiate the factors that may underlie this analgesic state. Ten unmedicated female patients with BPD (according to DSM-IV) and 14 healthy female control subjects were investigated using brief radiant heat pulses generated by a thulium laser and five-channel LEP recording. Heat pulses were applied as part of a spatial discrimination task (two levels of difficulty) and during a mental arithmetic task. BPD patien…
The internal auditory artery: (embryology, anatomy, angiography, pathology).
1975
A review of the literature on the embryology, anatomy and angiography of the internal auditory artery has shown that there may be considerable variation as to the origin and number of internal auditory arteries. The present study, based on serial magnification angiographies of the internal auditory artery, has demonstrated 7 variants of the origin of this artery although in 45.4% of cases the internal auditory artery arose from the anterior inferior cerebellar artery. For the diagnosis of pathological processes in the cerebellopontine angle (tumors, sudden deafness, vascular abnormalities) magnification angiography is of special importance. Acoustic neurinomas in particular can be diagnosed…
Dipole Source Analysis of Laser-Evoked Subdural Potentials Recorded From Parasylvian Cortex in Humans
2003
The location of the human nociceptive area(s) near the Sylvian fissure is still controversial in spite of evidence from imaging and evoked potential studies that noxious heat stimuli activate somatosensory areas in that region. Some studies have suggested the secondary somatosensory cortex (SII) on the upper bank of the Sylvian fissure posterior to the central sulcus, others the anterior insula or parietal area 7b. In this study, we applied dipole source analysis techniques to laser-evoked potentials (LEPs) that were recorded from subdural grid electrodes in three patients. As a functional marker, auditory-evoked potentials (AEPs) with a generator on the opposite bank of the Sylvian fissur…
Distribution and phenotype ofGJB2mutations in 102 Sicilian patients with congenital non syndromic sensorineural hearing loss
2014
Objective: To evaluate the frequency of GJB2 mutations and their correlation with phenotype in Sicilian non-syndromic sensorineural hearing loss (NSHL) patients. Design: Sequencing of the coding region, basal promoter, exon 1, and donor splice site of the GJB2 gene; screening for the presence of the two common GJB6 deletions. Study sample: A cohort of 102 Sicilian NSHL patients. Results: Fifteen different mutations in GJB2 and seventeen different genotypes were detected. No GJB6 mutations were found. The hearing impairment was profound in the 64.72% of probands (mean PTA 0.25 – 4 kHz of 88.82 26.52 dB HL). A total of 81.37% of patients harboured at least one c.35delG allele; c.167delT and c…
Identification of D179H, a novel missense GJB2 mutation in a Western Sicily family
2013
The main purpose of this study was to describe a novel missense mutation (p.D179H) found in a Western Sicily family and to examine the genetic and audiologic profiles of all family members by performing a GJB2 and GJB6 mutations analysis and a complete audiologic assessment. The proband was a 3-month-old infant with a congenital profound sensorineural hearing loss; direct sequencing of the GJB2 revealed the presence of a c.35delG mutation in the heterozygous state and a heterozygous G[C transition at nucleotide 535 in trans; this novel mutation, called p.D179H, resulted in an aspartic acid to histidine change at codon 179. It was also evidenced in the heterozygous state in two members of th…
Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…
2010
Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
Analysis of Fifty-Six Cochlear Implant Device Failures
2008
<i>Objective:</i> Our aim was to present a failure analysis after cochlear implant revision surgery in a large series of children and adults and to assess the outcome and audiologic performance. <i>Methods:</i> Fifty-six cochlear implant failures that occurred in 422 devices implanted between 1990 and 2007 at the Department of Otolaryngology, Head and Neck Surgery at the University of Mainz, Germany, were retrospectively analyzed. The causes of failure were reviewed evaluating the individual history, telemetric and intraoperative findings and manufacturer’s investigation reports. <i>Results:</i> We performed 56 surgical revisions in a series of 422 consec…