Search results for "Autofluorescence"
showing 10 items of 62 documents
Photobleaching measurements of pigmented and vascular skin lesions: results of a clinical trial
2011
The autofluorescence photobleaching intensity dynamics of in vivo skin and skin pathologies under continuous 532 nm laser irradiation have been studied. Overall the 141 human skin malformations were investigated by laser induced skin autofluorescence photobleaching analysis. Details of equipment are described along with some measurement results illustrating potentiality of the technology.
Imaging of LED-excited autofluorescence photobleaching rates for skin diagnostics
2019
The aim of this study is to develop a novel non-invasive approach for skin cancer (melanoma, basal cell and squamous cell carcinomas) diagnostics by mapping the AF intensity decrease (photo-bleaching) rates under continuous 405 nm LED excitation. For parametric mapping of skin AF intensity decrease rates a sequence of filtered AF imaging under 405 nm LED excitation for 20 seconds at a power density of ~7 mW/cm2 with a frame rate 0.5 fps was recorded and analyzed by cloud-based prototype device. Several clinical cases and potential future applications of the proposed autofluorescence photobleaching rate imaging technique are discussed.
Polylactic is a Sustainable, Low Absorption, Low Autofluorescence Alternative to Other Plastics for Microfluidic and Organ-on-Chip Applications
2020
Organ-on-chip (OOC) devices are miniaturized devices replacing animal models in drug discovery and toxicology studies. The majority of OOC devices are made from polydimethylsiloxane (PDMS), an elastomer widely used in microfluidic prototyping, but posing a number of challenges to experimentalists, including leaching of uncured oligomers and uncontrolled absorption of small compounds. Here we assess the suitability of polylactic acid (PLA) as a replacement material to PDMS for microfluidic cell culture and OOC applications. We changed the wettability of PLA substrates and demonstrated the functionalization method to be stable over a time period of at least 9 months. We successfully cultured …
3-D image analysis of fluorescent drug binding
2004
Fluorescent ligands provide the means of studying receptors in whole tissues using confocal laser scanning microscopy and have advantages over antibody- or non-fluorescence-based method. Confocal microscopy provides large volumes of images to be measured. Histogram analysis of 3-D image volumes is proposed as a method of graphically displaying large amounts of volumetric image data to be quickly analyzed and compared. The fluorescent ligand BODIPY FL-prazosin (QAPB) was used in mouse aorta. Histogram analysis reports the amount of ligand-receptor binding under different conditions and the technique is sensitive enough to detect changes in receptor availability after antagonist incubation or…
Multispectral and autofluorescence RGB imaging for skin cancer diagnostics
2019
This paper presents the results of statistical clinical data, combining two diagnostic methods. A combination of two skin imaging methods – diffuse reflectance and autofluorescence – has been applied for skin cancer diagnostics. Autofluorescence (AF) and multispectral diffuse reflectance images were acquired by custom made prototype with 405 nm, 526 nm, 663 nm and 964 nm LEDs and RGB CMOS camera. Parameter p’ was calculated from diffuse reflectance images under green, red and infrared illumination, AF intensity (I’) was calculated from AF images exited at 405nm wavelength. Obtained results show that criterion p` > 1 gives possibility to discriminate melanomas and different kind of keratosis…
Lasers for in-vivo skin diagnostics: some recent developments
2019
The recent advancements of three laser-based diagnostic technologies developed at the Riga group are briefly reviewed: (i) RGB imaging of cw-laser excited skin autofluorescence intensity and photobleaching rate distributions, (ii) ps-laser excited skin autofluorescence and diffuse reflectance kinetics analysis, (iii) snapshot RGB skin chromophore mapping under triple-laser illumination. These techniques have passed preliminary laboratory and clinical tests which have demonstrated a promising potential for further implementation in portable devices for routine clinical applications. Operation principles, set-up schemes and some clinical results obtained by the above-mentioned techniques are …
Advanced imaging of the gastrointestinal tract: research vs. clinical tools?
2009
Diagnostic endoscopy has moved forward considerably in the recent years. Still, three major needs have to be satisfied: endoscopy should be able to detect a lesion, characterize the lesion, and then its nature should be confirmed. These steps should ideally translate into an immediate therapeutic decision.High definition endoscopy has optimized our endoscopic view onto the mucosa and can be combined with digital surface enhancement modalities. Chromoendoscopy still holds a place to detect especially flat lesions in high-risk patients such as ulcerative colitis. Digital chromoendoscopy techniques such as narrow band imaging, i-scan, or Fuji intelligent chromo endoscopy offer new possibilitie…
Blue autofluorescence in protein aggregates “lighted on” by UV induced oxidation
2019
Oxidation of amino acid side chains in protein structure can be induced by UV irradiation leading to critical changes in molecular structure possibly modifying protein stability and bioactivity. Here we show, by using a combination of multiple spectroscopic techniques and Fluorescence Lifetime Imaging, that UV-light exposure induces irreversible oxidation processes in Ubiquitin structure. In particular, the growth of a new autofluorescence peak in the blue region is detected, that we attribute to tyrosine oxidation products. Blue autofluorescence intensity is found to progressively increase also during aggregation processes leading to the formation of aggregates of non-amyloid nature. Signi…
Optical design improvement for noncontact skin cancer diagnostic device
2018
Multispectral diffuse reflectance imaging and autofluorescence photo-bleaching imaging are methods that have been investigated for use in skin disorder diagnostics. In response to the ever-increasing incidence of skin cancer in light skinned populations a new device has been designed incorporating both of these methods. The aim of the study was to create a device that is most efficient in terms of hardware and software parameters for the screening of malignant and benign skin lesions. A set of 525 nm, 630 nm and 980 nm LEDs were used to illuminate the skin area at three wavelengths [1] and a set of 405 nm LEDs were used to induce the skin autofluorescence [2]. For a more homogenous illumina…
Ādas fulorescences un izkliedes kinētikas mērījumi pikosekunžu lāzera ierosmē
2017
Lai gan pirmajā acu uzmetienā ādas autofluorescence un starojuma izkliedes kinētikas ir it kā vienkāršas metodes vides pētīšanai un tās parametru noteikšanai, tieši tāpēc tās ir efektīvas. Izmantojot ādas veidojumu raksturošanai metodes, kas nav nepamatoti sarežģītas, iespējams iegūt lielumus, kas raksturo dažādas ādas pataloģijas. Fotonu uzvedības ādā apraksts ir svarīga sastāvdaļa optiskās diagnostikas attīstībai. Darbā tika pētīti ādas veidojumi, izmantojot autofluroescences mērījumus un fotona lidojuma laika ādā mērījumus. Tika iegūti vairāki parametri, ar ko raksturot dažādas ādas pataloģijas, kā arī apskatīta korelācija starp autofluroescenci un fotona lidojuma laika ādā raksturlielum…