Search results for "BEAM"

showing 10 items of 2126 documents

Status of new 18 GHz ECRIS HIISI

2018

A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory at the University of Jyvaskyla (JYFL). The main purpose of HIISI is to produce high-energy beam cocktails, e.g. Xe44+, for radiation effects testing of electronics with the K130 cyclotron. The initial commissioning results in 18+14 GHz operation with oxygen, argon and xenon are reported. The beam currents are compared to those produced by reference ion sources (JYFL 14 GHz ECRIS, GTS and SuSI). At the moment (October 2017) 560 µA of O6+ and 310 µA of Ar13+, for example, have been reached with HIISI at 2.3 kW total power.A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory…

University of JyväskyläMaterials scienceCyclotrontutkimuslaitteetchemistry.chemical_elementRadiation01 natural sciences7. Clean energy010305 fluids & plasmasIonlaw.inventionNuclear physicsXenonHIISIlaw0103 physical sciencesheavy ion ion source injector010302 applied physicsArgonta114syklotronitIon sourcechemistrysäteilyfysiikkaMoment (physics)ionsaccelerator laboratoryBeam (structure)
researchProduct

Perioperative morbidity and rate of upstaging after laparoscopic staging for patients with locally advanced cervical cancer: results of a prospective…

2015

Objective The International Federation of Gynecology and Obstetrics (FIGO) staging for cervical cancer is based on clinical examination. Previous studies have demonstrated significant upstaging with surgical staging. However, no randomized trial has ever shown a survival benefit when radiation combined with chemoradiation (RCTX) is modified according to surgical staging. The objective of the study was to evaluate the feasibility and outcomes of surgical staging prior to radical RCTX treatment among patients with locally advanced cervical cancer in the setting of a larger, prospective, randomized study (the Uterus-11 study of the German Gynecologic Oncology Group). Study Design Between 2009 …

Uterine Cervical Neoplasmmedicine.medical_treatmentBrachytherapyUterine Cervical NeoplasmsCarcinoma AdenosquamouAntineoplastic AgentPostoperative ComplicationsLaparotomyrandomized triallocally advanced cervical cancerLaparoscopyCervical cancermedicine.diagnostic_testMedicine (all)Lymph NodeObstetrics and GynecologyChemoradiotherapyMiddle Agedlaparoscopic stagingTreatment OutcomeCarcinoma Squamous CellFemaleoperative morbidityHumanAdultmedicine.medical_specialtyPelviBrachytherapyAntineoplastic AgentsGynecologic oncologyAdenocarcinomaPelvisCarcinoma AdenosquamousYoung AdultmedicineHumansExternal beam radiotherapyAgedNeoplasm StagingRadiotherapybusiness.industryPostoperative complicationPerioperativemedicine.diseaseSurgeryFeasibility StudieFeasibility StudiesLymph Node ExcisionLaparoscopyPostoperative ComplicationLymph NodesCisplatinbusinessAmerican journal of obstetrics and gynecology
researchProduct

Resist-based silver nanocomposites synthesized by lithographic methods

2010

In this work, the formation of silver metal nanoparticles inside a negative-tone resist based on poly(vinyl alcohol) is achieved by electron beam lithography. The chemistry of this sensitive resist allows the production of nanoparticles as well as the polymer crosslinking by the electron radiation. Due to the presence of the silver nanoparticles, the final composite exhibits a plasmonic behavior, which was characterized by measuring the absorbance. The lithographic properties of the resist have been characterized. The technique has also been exported to UV lithography, where silver nanoparticles are obtained inside the polymeric patterns after optical lithography.

Vinyl alcoholMaterials sciencetechnology industry and agricultureNanoparticleNanotechnologyPhotoresistCondensed Matter PhysicsAtomic and Molecular Physics and OpticsSilver nanoparticleSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialslaw.inventionchemistry.chemical_compoundchemistryResistlawElectrical and Electronic EngineeringPhotolithographyLithographyElectron-beam lithographyMicroelectronic Engineering
researchProduct

E-beam crosslinked, biocompatible functional hydrogels incorporating polyaniline nanoparticles

2012

Abstract PANI aqueous nanocolloids in their acid-doped, inherently conductive form were synthesised by means of suitable water soluble polymers used as stabilisers. In particular, poly(vinyl alcohol) (PVA) or chitosan (CT) was used to stabilise PANI nanoparticles, thus preventing PANI precipitation during synthesis and upon storage. Subsequently, e-beam irradiation of the PANI dispersions has been performed with a 12 MeV Linac accelerator. PVA-PANI nanocolloid has been transformed into a PVA-PANI hydrogel nanocomposite by radiation induced crosslinking of PVA. CT-PANI nanoparticles dispersion, in turn, was added to PVA to obtain wall-to-wall gels, as chitosan mainly undergoes chain scission…

Vinyl alcoholRadiationNanocompositeAqueous solutionMaterials scienceAbsorption spectroscopyNanoparticleChitosanchemistry.chemical_compoundchemistryChemical engineeringHydrogels polyaniline nanocomposites e-beam irradiationPolymer chemistryPolyanilineSelf-healing hydrogelsSettore CHIM/07 - Fondamenti Chimici Delle TecnologieHydrogels Polyaniline Nanocomposites e-Beam irradiation UV-vis absorption spectroscopy Emission spectroscopyRadiation Physics and Chemistry
researchProduct

Mechanical Behavior Of Fractional Visco-Elastic Beams

2012

Visco-elastic beamSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct

Stochastic dynamic analysis of structures with fractional viscoelastic constitutive laws

The main purpose of this thesis is to provide a new way to correctly perform stochastic analysis of structures with viscoelastic constitutive law. The reason for this kind of problem relates the fact that structures with viscoelastic materials are built in many areas of mechanical, civil and aerospace engineering. To perform this kind of stochastic analysis there are two fundamental problems. That is, the mechanical description of the viscoelastic phenomenon, and the correct representation of the external loads. Both of these problems are addressed and solved by the proposed modeling that involves some advanced mathematical tools. The reason to describe materials as viscoelastic is given by…

Viscoelastic Constitutive LawFractional CalculuContinuous and Discrete ModelMechanical ModelingRandom ProcesseViscoelastic Euler-Bernoulli BeamFractional Multi-Degree-Of-Freedom SystemStochastic Analysi
researchProduct

Adénocarcinome de la glande lacrymale dans un rétinoblastome bilatéral traité avec radiothérapie externe : à propos d’un cas

2011

This clinical case report describes the clinical findings and diagnosis of lacrimal gland adenocarcinoma that developed 20 years after external beam radiotherapy in the treatment of bilateral retinoblastoma. Visual acuity, slit lamp biomicroscopy, fundus color photography, nuclear magnetic resonance, lateral orbitotomy and histological analysis are described.

Visual acuityRadiotherapygenetic structuresLacrimal Gland AdenocarcinomaSettore MED/30 - Malattie Apparato Visivobusiness.industrymedicine.medical_treatmentFundus (eye)eye diseasesRadiation therapyBilateral retinoblastomaOphthalmologyLateral orbitotomyAdenocarcinoma of the lacrimal gland; Radiotherapy; Bilateral retinoblastomaAdenocarcinoma of the lacrimal glandmedicinesense organsExternal beam radiotherapyBilateral retinoblastomaSlit lamp biomicroscopymedicine.symptombusinessNuclear medicineJournal Français d'Ophtalmologie
researchProduct

Analytical model of transit time broadening for two-photon excitation in a three-level ladder and its experimental validation

2012

We revisit transit time broadening for one of the typical experiment designs in molecular spectroscopy, that of a collimated supersonic beam of particles crossing a focused Gaussian laser beam. In particular, we consider a Doppler-free arrangement of a collimated supersonic beam of Na${}_{2}$ molecules crossing two counterpropagating laser beams that excite a two-photon transition in a three-level ladder scheme. We propose an analytical two-level model with a virtual intermediate level to show that the excitation line shape is described by a Voigt profile and provide the validity range of this model with respect to significant experimental parameters. The model also shows that line broadeni…

Voigt profilePhysicsField (physics)CurvatureLaserAtomic and Molecular Physics and OpticsCollimated lightlaw.inventionComputational physicsNuclear magnetic resonancelawPhysics::Accelerator PhysicsParticle beamExcitationBeam (structure)Physical Review A
researchProduct

Tests of atomic charge-exchange cells for collinear laser spectroscopy

2012

Abstract The performance characteristics of two charge-exchange cells (CECs) with horizontal and vertical cell configurations were determined by neutralizing a 10-keV rubidium ion beam in a potassium vapor. The neutralization efficiency and the fluorescence line shape of the 5s 2 S 1 / 2 ↔ 5 p 2P3/2 (D2) transition in neutral 85Rb were investigated as a function of the reservoir temperature used to control the potassium vapor density. The CECs exhibited similar neutralization performance and at neutralization efficiencies greater than 25–50% an asymmetric line shape of the rubidium D2 fluorescent signal was observed. The asymmetry was attributed to inelastic channels in the charge-exchange …

Voigt profilePhysicsNuclear and High Energy PhysicsIon beamchemistry.chemical_elementResonanceIsotopes of rubidiumSpectral lineRubidiumIonchemistryAtomic physicsSpectroscopyInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A new FESEM procedure for assessment of XRD microstructural data of kaolinites

2007

Abstract A sample preparation method for FESEM microstructural analysis of sheet silicates using oriented aggregates on metallic strips parallel to the electronic beam is described. The method allows the easy measurement of thickness of kaolinite crystallites. The results have been compared to the apparent crystallite size measured by XRD The performed measurements for a set of selected kaolinites are in the range 15–60 nm and show a good correlation with XRD crystallite thickness (in the range 11–48 nm) obtained by the Voigt function method.

Voigt profilechemistry.chemical_compoundMaterials sciencechemistryGeochemistry and PetrologyMineralogyKaoliniteGeologySample preparationCrystalliteComposite materialBeam (structure)SilicateApplied Clay Science
researchProduct