Search results for "BEAMS"

showing 10 items of 268 documents

Symplectic analysis of thin-walled curved box girders with torsion, distortion and shear lag warping effects

2022

Shear lag effect and torsional and distortional warping can significantly affect the performance of thin-walled curved box girders used in modern bridge engineering. The structural behaviour of these bridges exhibits complexity due to coupled bending and torsion together with warping effects of non-uniform torsion, distortion and shear lag. A practical method of analysis, based on the symplectic approach, with the same perspective as the Higher Order Beam Theories, is presented for overcoming the difficulties of numerical approaches via the Finite Element Method. In this paper, the Hamiltonian Structural Analysis method implements the analysis of the shear lag effect together with non-unifo…

WarpingSymplectic ElasticityHamiltonian Structural AnalysisMechanical EngineeringShear-lagTimoshenko curved beamsDistortionBuilding and ConstructionCurved bridgesNon-uniform torsionGBTThin-walled beamsBox girdersHigher Order Beam TheoriesCivil and Structural Engineering
researchProduct

Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

2019

The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…

Wire chambers (MWPCdrift tube13000 GeV-cmsPhysics::Instrumentation and DetectorsmuonsTracking (particle physics)01 natural sciences030218 nuclear medicine & medical imagingHigh Energy Physics - ExperimentSubatomär fysikMWPCHigh Energy Physics - Experiment (hep-ex)Gaseous detectors0302 clinical medicineWire chambersDrift tubesSubatomic Physicsscattering [p p][PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]tracking detectorProportional chambersmomentum resolutionInstrumentationImage resolutionMathematical Physicsdrift tubesPhysicsLarge Hadron ColliderDrift chamberstrack data analysisMuon spectrometersResolution (electron density)DetectorSettore FIS/01 - Fisica SperimentaleATLAS:Mathematics and natural scienses: 400::Physics: 430::Nuclear and elementary particle physics: 431 [VDP]Wire chambers (MWPC Thin-gap chambers drift chambers drift tubes proportional chambers etc)medicine.anatomical_structureCERN LHC Collproportional chambers etc)Gaseous detectors; Muon spectrometers; Particle tracking detectors (gaseous detectors); Wire chambers (MWPC thin-gap chambers drift chambers drift tubes proportional chambers etc)MDT chambersWire chambers (MWPC)LHCcolliding beams [p p]Particle Physics - Experimentp p: scatteringspectrometer [muon]Ciências Naturais::Ciências Físicas530 PhysicsParticle tracking detectors (Gaseous detectors):Ciências Físicas [Ciências Naturais]610FOS: Physical sciencesdrift chamber [muon]gas [monitoring]programming03 medical and health sciencesOpticsAtlas (anatomy)Muon spectrometer0103 physical sciencesCalibrationmedicinemuon: drift chamberGaseous detectorddc:610drift chambersHigh Energy Physicsspatial resolutionMuonScience & Technology010308 nuclear & particles physicsbusiness.industryhep-ex:Matematikk og naturvitenskap: 400::Fysikk: 430::Kjerne- og elementærpartikkelfysikk: 431 [VDP]Thin-gap chamberscalibrationmonitoring: gasExperimental High Energy Physicsbusinessp p: colliding beamsmuon: spectrometerexperimental results
researchProduct

Crystalline-Size Dependence of Dual Emission Peak on Hybrid Organic Lead-Iodide Perovskite Films at Low Temperatures

2018

In this work, we have investigated the crystalline-size dependence of optical absorption and photoluminescence emission of CH3NH3PbI3 films, which is necessary to identify the potential practical applications of the gadgets based on perovskite films. This study was carried out at low temperatures to minimize the extra complexity induced by thermal effects. The purpose was to clarify the origin of the dual emission peak previously reported in the literature. We found that the grain size is responsible for the appearance or disappearance of this dual emission on CH3NH3PbI3 at low temperatures, whereas we have inferred that the thickness of the perovskite layer is a much more important factor …

Work (thermodynamics)PhotoluminescenceMaterials scienceexcitonsBand gapparticle beamsExcitonIodideBinding energyAnalytical chemistry02 engineering and technology010402 general chemistry7. Clean energy01 natural sciencesiodine compoundsCondensed Matter::Materials Sciencegrain size and shapePhysical and Theoretical Chemistrytemperature dependenceAbsorption (electromagnetic radiation)perovskitesemiconductor quantum wellsPerovskite (structure)chemistry.chemical_classificationFísicabinding energy021001 nanoscience & nanotechnologycrystalline materials0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialsenergy gapGeneral Energychemistrylayered semiconductorssolar cellslight absorptionphotoluminescence0210 nano-technologyThe Journal of Physical Chemistry C
researchProduct

Effect of gaseous impurities and the laser optics

2004

The impurities into the volume of a material appear while the elaboration process of the considered material. If a material is non-homogenous, even if we machine this material by means of a classical technology we could remark some differences in the machining process like cutting, drilling a.s.o. even in the process of welding. The impurities may be gaseous or solid. Each kind of impurity has another effect for the classical tool, or for a non-traditional tool i.e. a kind of concentrated energy. Each kind of medium has another reaction versus laser beam, because each medium has other physical characteristics. The modifications of characteristics require modifications of photon beam paramet…

Work (thermodynamics)PhotonMaterials sciencebusiness.industryProcess (computing)Mechanical engineeringWeldingLaserLaser opticslaw.inventionOpticsImpuritylawbusinessLaser beamsSPIE Proceedings
researchProduct

Electron and photon energy calibration with the ATLAS detector using 2015-2016 LHC proton-proton collision data

2019

Artículo realizado por muchos autores. Solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración y los autores que firman como pertenecientes a la UAM

Z0 --> electron positronJ/psi(3100) --> electron positronProton13000 GeV-cmsparticle identification [electron]ElectronZ0 --> electron positronelectron: transverse momentum01 natural sciencesphoton: particle identificationSubatomär fysik0302 clinical medicinescattering [p p]Nuclear Experiment proton–proton collisionsLarge Hadron ColliderCalibration and fittingphoton: transverse momentumand fitting methodsphoton: energy:Mathematics and natural scienses: 400::Physics: 430::Nuclear and elementary particle physics: 431 [VDP]calibration [energy]CERN LHC Collcalibration and fitting methodcolliding beams [p p]transverse momentum [electron]p p: scatteringCiências Naturais::Ciências Físicas610LHC ATLAS High Energy PhysicsPhoton energyFitting methodsJ/psi(3100) --> electron positronradiative decay [J/psi(3100)]Nuclear physicsMomentum03 medical and health sciencesAtlas (anatomy)High Energy Physicspair production [electron]CALORIMETERScience & Technologyradiative decay [Z0]electron: particle identification010308 nuclear & particles physicsenergy [photon]Acceleratorfysik och instrumentering jets energy: calibrationCalorimeter methodExperimental High Energy PhysicsPerformance of High Energy Physics Detectorsp p: colliding beamsacceptancetransverse momentum [photon]PhotonJ/psi(3100): radiative decayCalorimeter methods; Pattern recognition cluster finding calibration; and fitting methods; Performance of High Energy Physics Detectors; PARTON DISTRIBUTIONS; LIQUID AR; CALORIMETER; KR030218 nuclear medicine & medical imagingHigh Energy Physics - Experimentelectron: pair productionHigh Energy Physics - Experiment (hep-ex)Subatomic Physics[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Collisions Calorimeter methodsInstrumentationMathematical PhysicsBosonPhysicsPattern recognition cluster finding calibration and fitting methodsSettore FIS/01 - Fisica Sperimentalecalibration and fitting methodsATLASLIQUID ARmedicine.anatomical_structureKRCalibrationcalibration and fitting methods; Calorimeter methods; cluster finding; Pattern recognition; Performance of High Energy Physics Detectors; Instrumentation; Mathematical PhysicsParticle Physics - Experiment530 Physics:Ciências Físicas [Ciências Naturais]FOS: Physical sciencesZ0: radiative decayAccelerator Physics and Instrumentationcalibration and fitting methods; Calorimeter methods; cluster finding; Pattern recognition; Performance of High Energy Physics DetectorsPattern recognition0103 physical sciencesmedicineddc:610hep-exCluster finding:Matematikk og naturvitenskap: 400::Fysikk: 430::Kjerne- og elementærpartikkelfysikk: 431 [VDP]particle identification [photon]FísicaPARTON DISTRIBUTIONSHigh Energy Physics::Experimentexperimental results
researchProduct

"Safe" Coulomb excitation of 30Mg.

2004

We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient $\gamma$ -spectrometer MINIBALL. Using $^{30}$Mg ions accelerated to an energy of 2.25MeV/u together with a thin $^{nat}$Ni target, Coulomb excitation of the first excited 2+ states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative de-excitation $\gamma$ -ray yields the B(E2; 0$^{+}_{gs} \rightarrow 2^{+}_{1}$) value of $^{30}$Mg was determined to be 241(31)$e^{2}$fm$^{4}$. Our result is lower than values obtained at projectile fragmenttion facilities using the intermediate-ene…

[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]Coulomb excitationFOS: Physical sciencesPhysics::Accelerator PhysicsNuclear Physics - Experiment25.70.De 27.30.+t 21.10.ReNuclear Experiment (nucl-ex)[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear ExperimentNuclear ExperimentCollective levels20 < A < 38Radioactive beamsPhysical review letters
researchProduct

Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL

2011

International audience; As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to postacceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R&D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the gui…

[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonanceplasmafysiikka01 natural sciences7. Clean energyElectron cyclotron resonanceIonlaw.inventionIsotope separationelectron beamsNuclear physicsEURISOLion sourceslaw0103 physical sciencescyclotron resonance010306 general physicsradioactive ion beamsradioactive beamInstrumentation010302 applied physicsPhysicsta11429.25.Ni 41.75.Fr 07.77.KaionilähteetParticle acceleratorradioaktiiviset suihkutIon sourceCathode rayAtomic physicsydinfysiikkaIon cyclotron resonance
researchProduct

Real time measurement of long parabolic optical similaritons

2008

International audience; Long optical similaritons using a Raman fibre amplifier are generated. These pulses, with a highly parabolic profile, are monitored in real time on a high speed oscilloscope. Tunability of both the temporal and spectral widths of the pulses is then investigated.

[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics]Materials science02 engineering and technologyRaman amplifier01 natural sciencesOptical fibre amplifiers010309 opticssymbols.namesake020210 optoelectronics & photonicsOptics0103 physical sciencesSpectral width0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringOscilloscopeLaser beamsOptical amplifierOptical similaritons[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryPulse measurementFibre amplifiersymbolsRaman spectroscopybusinessOptical amplifier
researchProduct

Comparison between 2 Different Composite Nd3+:YVO4 Crystals in a Fibre Coupled Diode Pumped Laser

2008

International audience; We detail the performances of two composite Nd3+YVO4crystals, realised with two different sticking techniques. We tested them inside a fibre coupled diode end pumped laser.

[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics][PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]Materials sciencebusiness.industryComposite number02 engineering and technologyLaser01 natural scienceslaw.invention010309 optics# (140.3480) Lasers and laser optics : Lasers diode-pumped020210 optoelectronics & photonicsOpticslaw0103 physical sciences0202 electrical engineering electronic engineering information engineeringOptoelectronicsbusinessLaser beamsComputingMilieux_MISCELLANEOUSDiode
researchProduct

Characterization of alanine EPR detectors response in clinical carbon ion beams

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumors localized close to organs at risk [1]. Although ion beam radiotherapy ultimately requires dose prescription in terms of biological dose or cell survival, absorbed dose is still the quantity mostly used in clinical quality assurance and to dosimetrically characterize the beam. Moreover, the nuclear projectile fragmentation of heavy ions because of inelastic nuclear interactions with medium produces secondary particles with lower Z. The detailed know…

alanine EPR dosimeterscarbon ion beamsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct