Search results for "BM"
showing 10 items of 1459 documents
One center experience of pneumatosis cystoides intestinalis
2017
Introduction Pneumatosis cystoides intestinalis (PCI) is a rare benign condition, in which gas is found in a linear or cystic form in the subserosa or submucosa. The subserous cysts are most frequently found in the small bowel while the submucous localizations are predominantly seen in the colonic wall. Peritoneal pneumatosis, abdominal gas cysts, cystic lymphopneumatosis, intestinal emphysema or intestinal gas cysts are terms used to describe the occurrence of multiple, gas-filled cysts, of the gastrointestinal tract. Incidence of PCI was reported to be 0.03% in the general population. It is a radiographic finding and not a diagnosis, as the etiology varies from benign conditions to fulmin…
Incorporation and metabolism of trans 20∶5 in endothelial cells. Effect on prostacyclin synthesis
2000
To study the ability of long-chain trans fatty acids (FA) to be incorporated and metabolized into endothelial cells, bovine aortic endothelial cells were incubated with medium enriched eicosapentaenoic acid (EPA) bound to albumin (M2) or one of its geometrical isomers: 20:5 5c,8c,11t,14c,17c (M3), 20:5 5c,8c,11c,14c,17t (M4), or 20:5 5c,8c,11t,14c,17t (M5). After 48 h of incubation, supernatant and cells were harvested and their lipids were analyzed, including prostacyclin synthesis. EPA and 22:5n-3 of endothelial cells incubated with M2 were, respectively, three and two times higher than in control cells (incubated in M1, without any fatty acid added), whereas 22:6n-3 increased only in the…
Designing an AnMBR-based WWTP for energy recovery from urban wastewater: The role of primary settling and anaerobic digestion
2015
The main objective of this paper is to assess different treatment schemes for designing a submerged anaerobic membrane bioreactor (AnMBR) based WWTP. The economic impact of including a primary settling (PS) stage and further anaerobic digestion (AD) of the wasted sludge has been evaluated. The following operating scenarios were considered: sulphate-rich and low-sulphate urban wastewater (UWW) treatment at 15 and 30 ºC. To this aim, the optimum combination of design/operating parameters that resulted in minimum total cost (CAPEX plus OPEX) for the different schemes and scenarios was determined. The AnMBR design was based on both simulation and experimental results from an AnMBR plant featuri…
IBM Intelligent Bricks project—Petabytes and beyond
2006
This paper provides an overview of the Intelligent Bricks project in progress at IBM Research. It describes common problems faced by data center operators and proposes a comprehensive solution based on brick architectures. Bricks are hardware building blocks. Because of certain properties, defined here, scalable and reliable systems can be built with collections of identical bricks. An important feature is that brick-based systems must survive the failure of any brick without requiring human intervention, as long as most bricks are operational. This simplifies system management and allows very dense and very scalable systems to be built. A prototype storage server in the form of a 3 × 3 × 3…
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…
Global sensitivity analysis of a filtration model for submerged anaerobic membrane bioreactors (AnMBR)
2014
The results of a global sensitivity analysis of a filtration model for submerged anaerobic MBRs (AnMBRs) are assessed in this paper. This study aimed to (1) identify the less- (or non-) influential factors of the model in order to facilitate model calibration and (2) validate the modelling approach (i.e. to determine the need for each of the proposed factors to be included in the model). The sensitivity analysis was conducted using a revised version of the Morris screening method. The dynamic simulations were conducted using long-term data obtained from an AnMBR plant fitted with industrial-scale hollow-fibre membranes. Of the 14 factors in the model, six were identified as influential, i.e…
Mathematical modelling of filtration in submerged anaerobic MBRs (SAnMBRs): long-term validation
2013
The aim of this study was the long-term validation of a model capable of reproducing the filtration process occurring in a submerged anaerobic membrane bioreactor (SAnMBR) system. The proposed model was validated using data obtained horn a SAnMBR demonstration plant fitted with industrial-scale hollow-fibre membranes. The validation was carried out using both lightly and heavily fouled membranes operating at different bulk concentrations, gas sparging intensities and transmembrane fluxes. Across a broad spectrum of operating conditions, the model correctly forecast the respective experimental data in the long term. The simulation results revealed the importance of controlling irreversible f…
Robust Tool Point Control for Offshore Knuckle Boom Crane
2011
Author's version of a chapter in the book: Proceedings of the 18th IFAC World Congress 2011. Also available from the publisher at: http://dx.doi.org/10.3182/20110828-6-IT-1002.03004
A Innovative Monitoring Underwater Buoy Systems (MUnBuS) for Marine and Rivers installation with IR-Cam, Instrumental Telemetry and Acoustic Data Acq…
2015
The proposed low cost systems shows the results obtained in the implementation and testing in marine environment of a Innovative Monitoring Underwater Buoy Systems for Marine and Rivers installation with IR-Cam, Instrumental Telemetry and Acoustic Data Acquisition Capability (MUnBuS). This concerning a innovative Monitoring Underwater Buoy Systems that can be remotely controlled from the ground, air, satellite and sea and from a Center of Supervision Telecontroller And Data Acquisition and Monitoring (Mobile-STADAM Center). The Buoy is hosts for the radio or satellite communication equipment, the downloading and telemetering data equipment and the photovoltaic power supply, board and underw…
A security and surveillance application of the innovative Monitoring Underwater Buoy Systems (MUnBuS) on the Protected Marine Area (AMP) of capo gall…
2015
The proposed low cost systems shows the results obtained in the implementation and testing on real security application to Protected Marine Area surface and submarine environment of a innovative Monitoring Underwater Buoy Systems (MUnBuS) for installation with IR-CCTV-Cam, ultrasonic dolphin warning system and Green Laser Perimeter Detection. This concerning innovative Monitoring Underwater Buoy Systems that can be remotely controlled from the ground, air, satellite and sea and from a Center of Supervision Telecontroller And Data Acquisition and Monitoring (Mobile- STADAM Center). The Buoy is hosts for the radio or satellite communication equipment, the downloading and telemetering data equ…