Search results for "BUBBLES"
showing 10 items of 46 documents
Benign focal liver lesions: spectrum of findings on SonoVue-enhanced pulse-inversion ultrasonography.
2005
The prevalence of benign focal liver lesions (BFLL) is high both in the general population and in patients with known malignancies. The gray-scale ultrasound (US) technique is usually the first-line imaging modality used in the radiological workup of such lesions, but unfortunately it lacks specificity. Furthermore, Doppler examination may often be unsatisfactory owing to motion artefacts, or when small or deeply located lesions are evaluated. Recently, microbubble-based contrast agents used in combination with gray-scale US techniques, which are very sensitive to nonlinear behavior of microbubbles, have led to a better depiction of both microvasculature and macrovasculature of focal hepati…
Local gas-liquid hold-up and interfacial area via light sheet and image analysis
2010
Particle Image Velocimetry techniques coupled with advanced Image Processing tools are receiving an increasing interest for measuring flow quantities and local bubble-size distributions in gas-liquid contactors. In this work, an effective experimental technique for measuring local gas hold-up and interfacial area, as well as bubble size distribution, is discussed. The technique, hereafter referred to as Laser Induced Fluorescence with Shadow Analysis for Bubble Sizing (LIF-SABS) is based on laser sheet illumination of the gas-liquid dispersion and synchronized camera, i.e. on equipment typically available within PIV set-ups. The liquid phase is made fluorescent by a suitable dye, and an opt…
Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity
2010
To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…
Detection potential of the KM3NeT detector for high-energy neutrinos from the Fermi bubbles
2013
A recent analysis of the Fermi Large Area Telescope data provided evidence for a high-intensity emission of high-energy gamma rays with a E-2 spectrum from two large areas, spanning 50 above and below the Galactic centre (the "Fermi bubbles"). A hadronic mechanism was proposed for this gamma-ray emission making the Fermi bubbles promising source candidates of high-energy neutrino emission. In this work Monte Carlo simulations regarding the detectability of high-energy neutrinos from the Fermi bubbles with the future multi-km(3) neutrino telescope KM3NeT in the Mediterranean Sea are presented. Under the hypothesis that the gamma-ray emission is completely due to hadronic processes, the resul…
CFD prediction of bubbles local gas hold-up in 2-dimensional gas-solid fluidized beds
2008
Heterogeneous delayed enhancement of hepatic parenchyma after intravenous infusion of sonographic contrast agent: a new hypothesis
2007
Purpose. The aim of this paper was to report a heterogeneous latephase hepatic enhancement pattern observed after administration of a sonographic contrast agent and to present an aetiological hypothesis for the phenomenon. Materials and methods. A total of 1,729 (1,012 women and 717 men; age range 28–82; mean age 51) patients underwent contrastenhanced sonography of the liver. The examination was performed with a low mechanical index (MI <0.09) after injection of sulphur-hexafluoride-filled microbubbles, using different fonographic equipment and different contrast-specific algorithms. Results. Heterogeneous delayed liver enhancement was observed in six patients in the late phase (180 s), wi…
Numerical model for the shear rheology of two-dimensional wet foams with deformable bubbles
2014
Shearing of two-dimensional wet foam is simulated using an introduced numerical model, and results are compared to those of experiments. This model features realistically deformable bubbles, which distinguishes it from previously used models for wet foam. The internal bubble dynamics and their contact interactions are also separated in the model, making it possible to investigate the effects of the related microscale properties of the model on the macroscale phenomena. Validity of model assumptions was proved here by agreement between the simulated and measured Herschel-Bulkley rheology, and shear-induced relaxation times. This model also suggests a relationship between the shear stress and…
Involvement of Jugular Valve Insufficiency in Cerebral Venous Air Embolism
2007
Background. Cerebral venous air entrapment is a rare finding on cranial computed tomography (CT) scan. Peripheral air embolism is discussed as a potential cause. However, the mechanism of retrograde passage through internal jugular valves and veins is unclear. Case Report. The case of a patient is reported, who had air entrapment in the left cavernous sinus. Prior to CT scanning, a peripheral intravenous line had been placed. Ultrasound revealed excessive insufficiency of the left internal jugular valve. To further study the mechanism of embolism, an echo contrast agent was injected into the cubital vein. A Valsalva maneuver resulted in retrograde transition of microbubbles across the insuf…
Myocardial contrast echocardiography in biopsy-proven primary cardiac amyloidosis.
2008
Abstract Cardiac vasculature is affected in 88-90% of patients with primary cardiac amyloidosis (CA). Myocardial contrast echocardiography (MCE) relies on the ultrasound detection of microbubble contrast agents that are solely confined to the intravascular space, and are therefore useful in the evaluation of flow in the microvasculature. This is the first case report describing the use of MCE during vasodilator stress to evaluate coronary flow reserve in a patient with biopsy-proven primary CA and angiographically normal coronaries. Qualitative MCE demonstrated delayed replenishment of microbubbles during peak stress; quantitative analysis was consistent with a reduction in total myocardial…
On the bubbling dynamics of binary mixtures of powders in 2D gas-solid fluidized beds
2012
Abstract The bubbling behavior of fluidized beds has been thoroughly investigated in the last decades by means of several techniques (e.g. X-ray, Inductance, Resistance and Impedance based techniques). In recent years, Digital Image Analysis Techniques have shown their potential for accurate and cost effective measurements. Most of the works related to the experimental analysis of bubble behavior in the field of gas-solid fluidization actually deal with monodispersed particles although almost all industrial equipments operate with mixtures of particles. Among the works available in literature dealing with mixtures of particles having different diameters and/or densities, most of them aim at…