Search results for "Beamline"
showing 10 items of 77 documents
Progress in development of a new luminescence setup at the FinEstBeAMS beamline of the MAX IV laboratory
2019
The main funding for the FinEstBeAMS beamline has been obtained from the European Union through the European Regional Development Fund (project “Estonian beamline to MAX-IV synchrotron”, granted to the University of Tartu) and from the Academy of Finland through the Finnish Research Infrastructure funding projects ( FIRI2010 , FIRI2013 , FIRI2014 ). The authors also acknowledge the funding contributions of the University of Oulu , University of Turku , Tampere University of Technology , the Estonian Research Council ( IUT 2-25 , IUT 2-26 , PRG-111 ), as well as the Estonian Centre of Excellence in Research “Advanced materials and high-technology devices for sustainable energetics, sensorics…
CERN-MEDICIS: A Review Since Commissioning in 2017
2021
The CERN-MEDICIS (MEDical Isotopes Collected from ISolde) facility has delivered its first radioactive ion beam at CERN (Switzerland) in December 2017 to support the research and development in nuclear medicine using non-conventional radionuclides. Since then, fourteen institutes, including CERN, have joined the collaboration to drive the scientific program of this unique installation and evaluate the needs of the community to improve the research in imaging, diagnostics, radiation therapy and personalized medicine. The facility has been built as an extension of the ISOLDE (Isotope Separator On Line DEvice) facility at CERN. Handling of open radioisotope sources is made possible thanks to i…
The effects of precipitates on CdZnTe device performance
2005
A high-intensity X-ray beam collimated down to a 10-micrometer spot size, available at Brookhaven's National Synchrotron Light Source (NSLS), was employed to perform X-ray mapping to measure the correlation between microscopic defects (precipitates) and variations in the collected charges in long-drift CdZnTe (CZT) detectors. First, we use X-ray diffraction topography (XDT) measurements at the high-energy beamline and IR microscopy to identify the defects distribution and strains in the bulk of CZT crystals. Then, we perform X-ray raster scans of the CZT detectors to measure their responses with 10-micrometer spatial resolution. The brightness of the source allows for good statistics in ver…
Technology Impact on Neutron-Induced Effects in SDRAMs : A Comparative Study
2021
International audience; This study analyses the response of synchronous dynamic random access memories to neutron irradiation. Three different generations of the same device with different node sizes (63, 72, and 110 nm) were characterized under an atmospheric-like neutron spectrum at the ChipIr beamline in the Rutherford Appleton Laboratories, UK. The memories were tested with a reduced refresh rate to expose more single-event upsets and under similar conditions provided by a board specifically developed for this type of study in test facilities. The board has also been designed to be used as a nanosatellite payload in order to perform similar tests. The neutron-induced failures were studi…
Status report of the Jyvaskyla ion guide isotope separator on-line facility
1997
The ion guide isotope separator facility IGISOL of the University of Jyvaskyla has been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam diagnostics are discussed. The spectroscopy stations are introduced with illustrative examples from the research program, including beta-delayed proton and neutron spectroscopy, gamma-ray spectroscopy with and without arrays, conversion electron spectroscopy, collinear laser spectroscopy and nuclear level lifetime spectroscopy.
Fast and compact data acquisition for gas-filled detectors with delay line
2004
This article describes the functionality, implementation and performance of a PCI data acquisition board that can be used in conjunction with gas-filled detectors with delay line readout. The board combines a large on-board 256-MByte histogramming memory with a maximum 10-MHz count rate in continuous operation and integrates the time frame generation, histogram building and buffering functionalities in a single PCI board, resulting in a fast, compact and cost-effective data acquisition solution for the Spanish beamline BM16 at ESRF.
Measurement of high energy resolution inelastic proton scattering at and close to zero degrees
2009
13 pages, 15 figures.-- Printed version published Jul 1, 2009.
Laser photodetachment of radioactive $^{128}$I$^−$
2017
International audience; The first experimental investigation of the electron affinity (EA) of a radioactive isotope has been conducted at the CERN-ISOLDE radioactive ion beam facility. The EA of the radioactive iodine isotope (128)I (t (1/2) = 25 min) was determined to be 3.059 052(38) eV. The experiment was conducted using the newly developed Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) apparatus, connected to a CERN-ISOLDE experimental beamline. (128)I was produced in fission induced by 1.4 GeV protons striking a thorium/tantalum foil target and then extracted as singly charged negative ions at a beam energy of 20 keV. Laser photodetachment of th…
Upgrades to the collinear laser spectroscopy experiment at the IGISOL
2020
Abstract We give an overview of recent changes to the collinear laser spectroscopy beamline in the IGISOL laboratory. We present a new data acquisition system, commissioning of a newly installed charge exchange cell, and cooler-voltage calibration measurements. Currently ongoing modifications to the RFQ cooler-buncher are also discussed.
A new beamline for energy-dispersive high-resolution PIXE analysis using polycapillary optics
2019
Abstract A new beamline for high energy resolution PIXE measurements is presented. This new setup includes options for both in-air and vacuum measurements. For the high energy resolution transition-edge sensor array, a polycapillary lens is used for detecting low-energy X-rays down to 0.5 keV and to increase the effective solid angle. X-ray transmission of the polycapillary lens was characterized using two calibration standards. The gain obtained by adding a polycapillary lens was 1.6–2.3 at energies between 2.1 keV and 4.5 keV. From 1.04 to 1.74 keV the gain is increased to 2.1–3.0, and at energies 4.9–8.0 keV the gain is between 1.6 and 0.65. The measured gain agreed well with theoretical…