Search results for "Bending"
showing 10 items of 244 documents
On the long-term response of elastic-perfectly plastic solids to dynamic cyclic loads
1992
It is shown that the long-term response of an elastic-perfectly plastic solid subjected to dynamic actions cyclically varying in time is characterized by stresses, plastic strain rates and velocities that are all periodic with the same period of the external actions, and are in perfect analogy with the quasi-static case; on the other hand, plastic strains and displacements are in general nonperiodic (except in case of alternating plasticity) and may increase indefinitely (except when elastic or plastic shakedown occurs). Besides, the work performed by the external actions in the steady cycle equals the work performed by the elastic stresses (i.e. pertaining to the elastic response of the bo…
Il Dioniso delle "Baccanti" e i "piegatori di pini". Polivalenza di un'immagine leggendaria
2021
This paper investigates the mythical and ritual background of Dionysus’ representation as “fir-bender” in Euripides’ "Bacchae" (ll. 1061 ff.), in an attempt to shed light not only on the dramaturgical aspects of the tragic plot, but also on the cultural categories that make this representation intelligible to the Athenian audience at the end of the fifth century BC. Following Louis Gernet’s historical-anthropological approach based on the notion of "polyvalence des images", this paper aims to define a mythical pattern – the connection between the bending of a tree and the dismemberment of a human victim – already attested in the Attic legend of Theseus and Sinis, in which both characters se…
An exploration of the differences in hip strength, gluteus medius activity, and trunk, pelvis, and lower-limb biomechanics during different functiona…
2020
ABSTRACT The purpose of the study was to explore differences in the coronal biomechanics of the trunk, pelvis, hip, and knee joints, and gluteus medius muscle activity (GMed) during walking and step down from two riser heights. Joint kinematics and kinetics from 20 healthy participants were recorded using a 10-camera Qualisys system and force plates, and GMed EMG was recorded using a Delsys Trigno system. Hip abductor strength was measured using a hand-held dynamometer. Pelvic obliquity and lateral trunk bending excursions were significantly higher in walking than in step-down tasks. Significantly greater knee adduction moments were seen during both step-down tasks compared to level walking…
Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
2010
Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …
Low-temperature growth of n ++-GaN by metalorganic chemical vapor deposition to achieve low-resistivity tunnel junctions on blue light emitting diodes
2018
We report on low-resistivity GaN tunnel junctions (TJ) on blue light-emitting diodes (LEDs). Si-doped n ++-GaN layers are grown by metalorganic chemical vapor deposition directly on LED epiwafers. Low growth temperature (<800 °C) was used to hinder Mg-passivation by hydrogen in the p ++-GaN top surface. This allows achieving low-resistivity TJs without the need for post-growth Mg activation. TJs are further improved by inserting a 5 nm thick In0.15Ga0.85N interlayer (IL) within the GaN TJ thanks to piezoelectric polarization induced band bending. Eventually, the impact of InGaN IL on the internal quantum efficiency of blue LEDs is discussed.
Stress transfer and failure mechanisms in steel-concrete trussed beams: Experimental investigation on slab-thick and full-thick beams
2018
Abstract This study presents the results of an experimental investigation on semi-precast Hybrid Steel Trussed-Concrete Beams (HSTCBs) for analyzing the failure modes and the stress transfer mechanism between concrete and embedded steel elements (plate and truss). The available literature presents previous studies carried out by the authors mainly focused on the understanding of the local transfer mechanism by means of push-out tests. Conversely, in this paper original the results of laboratory tests conducted on six specimens of full-size HSTCBs subjected to four-point bending, with variation in the shear span, are reported on. From these results, the authors are able to assess the failure…
Moisture Absorption Effects on the Resistance to Interlaminar Fracture of Woven Glass/Epoxy Composite Laminates
2012
The influence of moisture absorption on the interlaminar fracture behaviour of 8/8 harness satin weave glass/epoxy composite was investigated. Two series of specimens with 0°/0° and 90°/90° predominant interfaces immersed in water for different duration were tested under double cantilever beam (DCB mode I), single leg bending (SLB mode I + II) and end notched flexural (ENF mode II) loadings. In general, the apparent flexural modulus: E, and the fracture toughness: G C, decrease with increasing moisture content. This effect is more remarkable if mode II participation is bigger. The value of G C measured on 90°/90° specimens reveals higher than that on 0°/0° ones, but the variation in G C is …
Investigating the mechanical properties of GeSn nanowires.
2019
Germanium tin (GeSn) has been proposed as a promising material for electronic and optical applications due to the formation of a direct band-gap at a Sn content >7 at%. Furthermore, the ability to manipulate the properties of GeSn at the nanoscale will further permit the realisation of advanced mechanical devices. Here we report for the first time the mechanical properties of GeSn nanowires (7.1-9.7 at% Sn) and assess their suitability as nanoelectromechanical (NEM) switches. Electron microscopy analysis showed the nanowires to be single crystalline, with surfaces covered by a thin native amorphous oxide layer. Mechanical resonance and bending tests at different boundary conditions were use…
Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel
2017
Background Titanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions. Material and Methods Seventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statis…
An Analytical Step-by-Step Procedure to Derive the Flexural Response of RC Sections in Compression
2013
This paper proposes an analysis procedure able to determine the flexural response of rectangular symmetrically reinforced concrete sections subjected to axial load and uniaxial bending. With respect to the usual numerical approaches, based on the fibre decomposition method, this procedure is based on the use of analytical expressions of the contributions to the equilibrium given by the longitudinal reinforcement and the concrete region in compression, which depend on the neutral axis depth and the curvature at each analysis step. The formulation is developed in dimensionless terms, after a preliminary definition of the geometrical and mechanical parameters involved, so that the results are …