Search results for "Biological effect"
showing 10 items of 28 documents
Physiological Effects of Thiobencarb Stress in the Eel (<i>Anguilla anguilla</i>)
2002
ヨーロッパウナギ Anguilla anguilla の代謝系へのチオベンカルブの影響と, 中毒からの回復とを評価した. 暴露期間ならびにそれに続く非汚染水中での8日間のウナギの血漿, 筋肉, 肝臓についてグリコーゲン, 脂質およびタンパクを測定した. 暴露により血糖値の上昇が認められたが, 肝臓と筋肉におけるグリコーゲンレベルは著しく低下した. 血中の脂質は増加したが, 肝臓での脂質は顕著に減少した. タンパク質の易動化は, とくに筋肉組織で認められた. ほとんどの代謝障害は, 非汚染水へ移した8日後まで継続した. 以上のチオベンカルブの代謝系への影響はある種のストレス症状であり, 魚類の農薬ストレスを代償しようとする生理的適応の具体例と考えられた.
In vitro quantitation of the effects of magnetic fields and radiofrequencies on amino acid metabolism
1996
The extensive use of Magnetic Resonance Imaging in medical diagnosis needs experimental confirmation of the real biological harmlessness of magnetic fields and radiofrequencies in the imaging process. To date, no unquestionable conclusions have been drawn and experimental results differ in various literature reports. We investigated the effects of radiofrequencies and magnetic fields on the amino acid content of plasma samples from 10 healthy volunteers aged 25 to 30 years; the samples were exposed for 60 minutes to MR fields at 0.5 T with the sequences commonly used in clinical practice. After exposure to magnetic fields, the samples were analyzed with chromatography and the results compar…
Citrus aurantium L. Active Constituents, Biological Effects and Extraction Methods. An Updated Review
2021
Citrus genus is a prominent staple crop globally. Long-term breeding and much hybridization engendered a myriad of species, each characterized by a specific metabolism generating different secondary metabolites. Citrus aurantium L., commonly recognized as sour or bitter orange, can exceptionally be distinguished from other Citrus species by unique characteristics. It is a fruit with distinctive flavor, rich in nutrients and phytochemicals which possess different health benefits. This paper presents an overview of the most recent studies done on the matter. It intends to provide an in-depth understanding of the biological activities and medicinal uses of active constituents existing in C. au…
Pharmacological Properties of Polyphenols: Bioavailability, Mechanisms of Action, and Biological Effects in In Vitro Studies, Animal Models, and Huma…
2021
Este artículo se encuentra disponible en la siguiente URL: https://www.mdpi.com/2227-9059/9/8/1074 Este artículo de investigación pertenece al número especial "Oxidative Stress and Inflammation: From Mechanisms to Therapeutic Approaches 2.0". Drugs are bioactive compounds originally discovered from chemical structures present in both the plant and animal kingdoms. These have the ability to interact with molecules found in our body, blocking them, activating them, or increasing or decreasing their levels. Their actions have allowed us to cure diseases and improve our state of health, which has led us to increase the longevity of our species. Among the molecules with pharmacological activity …
Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams
2018
The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…
Phantom size in brachytherapy source dosimetric studies
2004
An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…
Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.
2020
The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…
Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources
2005
In clinical brachytherapy dosimetry, a detailed dose rate distribution of the radioactive source in water is needed in order to plan for quality treatment. Two Cs-137 sources are considered in this study; the Radiation Therapy Resources 67-800 source (Radiation Therapy Resources Inc., Valencia, CA) and the 3M model 6500/6D6C source. A complete dosimetric dataset for both sources has been obtained by means of the Monte Carlo GEANT4 code. Dose rate distributions are presented in two different ways; following the TG43 formalism and in a 2D rectangular dose rate table. This 2D dose rate table is helpful for the TPS quality control and is fully consistent with the TG43 dose calculation formalism…
Reversible effect of MR and ELF magnetic fields (0.5 T and 0.5 mT) on human lymphocyte activation patterns.
2006
Purpose: The aim of this study was to investigate the effects of magnetic fields (MF) of different intensity generated by a magnetic resonance (MR) unit (0.5 Tesla) and a double cylindrical coil (0.5 mTesla) on human CD4+ T cell lines. Materials and methods: CD4+ T cells were exposed for two hours under isothermal conditions (37 ± 0.5°C) to the above mentioned MF; a control group was provided for each exposed sample. After exposure, the samples were analysed in the laboratory for the following endpoints: Release of cytokines, expression of surface markers, cell proliferation and levels of cytosolic free-calcium. Results: Exposure to MF for 2 h and subsequent in vitro stimulation in the pres…
Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398
2020
The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, kQ, for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamb…