Search results for "Biomaterial"

showing 10 items of 1350 documents

Study between anb angle and Wits appraisal in cone beam computed tomography (CBCT)

2013

Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying t…

AdultMaleCone beam computed tomographyAdolescentCephalometryDentistryLinear measurementMandibleNormal valuesClass iiiYoung Adultsymbols.namesakeImaging Three-DimensionalBiomaterials and Bioengineering in DentistryMaxillaHumansMedicineChildGeneral DentistryOrthodonticsbusiness.industryCone-Beam Computed TomographyCraniometryPearson product-moment correlation coefficientOtorhinolaryngologyMaxillasymbolsResearch-ArticleFemaleSurgeryMandibular plane anglebusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovin…

2012

Objectives The aim of this study was to perform an ultrastructural study of the bone-to-biomaterial interface and biomaterial mineral degradation in retrieved bone biopsies following maxillary sinus augmentation using bovine xenografts (Endobon®) in 15 clinical cases. Materials and methods Nine months after sinus lifting, bone cores were harvested from the maxillary sinus. The specimens were processed for observation under a scanning electron microscope with backscattered electron imaging (SEM-BSE). In addition, chemical analysis and elemental mapping of the mineral composition were generated using a microanalytical system based on energy-dispersive X-ray spectrometry (EDX). Results No clin…

AdultMaleSinus Floor AugmentationMaxillary sinusScanning electron microscopeSurface PropertiesBiopsyDentistrySinus Floor AugmentationMicroanalysisSurgical FlapsmedicineAnimalsHumansSinus (anatomy)Chemistrybusiness.industryJaw Edentulous PartiallyDental Implantation EndosseousBiomaterialSpectrometry X-Ray EmissionMaxillary SinusMiddle AgedResorptionmedicine.anatomical_structureTreatment OutcomeElemental analysisMicroscopy Electron ScanningHeterograftsCattleFemaleCollagenOral SurgerybusinessBiomedical engineeringClinical oral implants research
researchProduct

Three-year clinical performance of two indirect composite inlays compared to direct composite restorations

2013

Objective: Despite the incremental build-up of resin composite restorations, their polymerization shrinkage during curing presents a serious problem. Indirect composite resin systems represent an alternative in overcoming some of the deficiencies of direct composite restorations. The hypothesis of the present study states that the clinical performance of restorations may be affected by different generation and application techniques. Study Design: Sixty restorations (20 DI system (Coltene/Whaledent AG, Altstatten, Switzerland) composite inlays, 20 Tescera ATL system (BISCO Inc. Schaumburg, Illinois, USA) composite inlays, and 20 direct composites) were applied to premolar teeth in 49 patien…

AdultMaleTime FactorsResin compositeResin restorationsComposite numberDentistryOdontologíaComposite ResinsDental Restoration WearClinical studyBiomaterials and Bioengineering in DentistryMaterials TestingPremolarmedicineHumansGeneral DentistryInlaybusiness.industrytechnology industry and agricultureClinical performance:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludDental Restoration Wearmedicine.anatomical_structureOtorhinolaryngologyInlaysUNESCO::CIENCIAS MÉDICASResearch-ArticleFemaleSurgerybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Neutrophil‐mediated enhancement of angiogenesis and osteogenesis in a novel triple cell co‐culture model with endothelial cells and osteoblasts

2017

Repair and regeneration of critical‐sized bone defects remain a major challenge in orthopaedic and craniomaxillofacial surgery. Until now, attempts to bioengineer bone tissue have been hindered by the inability to establish proper angiogenesis and osteogenesis in the tissue construct. In the present study, we established a novel triple cell co‐culture model consisting of osteoblasts, endothelial cells, and neutrophils and conducted a systematic investigation of the effects of neutrophils on angiogenesis and osteogenesis. Neutrophils significantly increased angiogenesis in the tissue construct, evidenced by the formation of microvessel‐like structures with an extensive lattice‐like, stable t…

AdultMaleVascular Endothelial Growth Factor A0301 basic medicineTime FactorsNeutrophilsAngiogenesis0206 medical engineeringCellBiomedical EngineeringBone MatrixNeovascularization PhysiologicMedicine (miscellaneous)02 engineering and technologyMatrix metalloproteinaseBone tissueBone morphogenetic protein 2BiomaterialsYoung Adult03 medical and health sciencesCalcification PhysiologicTissue engineeringOsteogenesisHuman Umbilical Vein Endothelial CellsmedicineHumansViability assayCell ShapeBone growthOsteoblastsChemistryTransendothelial and Transepithelial Migration:Chemical engineering [Engineering]Middle Aged020601 biomedical engineeringCoculture TechniquesCell biology030104 developmental biologymedicine.anatomical_structureGene Expression RegulationFemaleAngiogenesisBiomarkersBiomedical engineeringJournal of Tissue Engineering and Regenerative Medicine
researchProduct

Cutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles

2016

International audience; Electronic textiles are an emerging field providing novel and non-intrusive solutions for healthcare. Conducting polymer-coated textiles enable a new generation of fully organic surface electrodes for electrophysiological evaluations. Textile electrodes are able to assess high quality muscular monitoring and to perform transcutaneous electrical stimulation.

AdultMalegradientsMaterials scienceBiomedical EngineeringPharmaceutical ScienceElectric Stimulation Therapy02 engineering and technology010402 general chemistry01 natural sciencesstimulationBiomaterialselectrochemical transistorexcitabilityHumansPEDOT:PSSneural interfacesMuscle activityMuscle SkeletalTextile electrodesElectrodespolymersmuscle activityElectromyographyTextiles[SCCO.NEUR]Cognitive science/Neurosciencepoly(3Transcutaneous Electrical Stimulationsmart textilereflex021001 nanoscience & nanotechnologyelectrophysiology0104 chemical sciencesmicroelectrode arrays[ SCCO.NEUR ] Cognitive science/Neurosciencenanoparticles4-ethylenedioxythiophene)0210 nano-technologyBiomedical engineering
researchProduct

Unfractionated Heparin Versus Subcutaneous Nadroparin in Adults Supported With Venovenous Extracorporeal Membrane Oxygenation: a Retrospective, Multi…

2021

Extracorporeal membrane oxygenation (ECMO) requires constant management of coagulation. Whereas unfractionated heparin remains the anticoagulant of choice, experienced centers report high bleeding rates. Biocompatibility of the extracorporeal circuit enables management of anticoagulation with subcutaneous low-molecular-weight heparins only. The aim of this study was to evaluate the safety and feasibility of anticoagulation with subcutaneous nadroparin compared with unfractionated heparin during respiratory ECMO in patients. We assessed for thrombotic complications and number of bleeding and life-threatening bleeding events. Additionally, we evaluated the change in resistance to flow in the …

AdultMalemedicine.drug_classmedicine.medical_treatmentBiomedical EngineeringBiophysicsBioengineering030204 cardiovascular system & hematologyExtracorporealBiomaterials03 medical and health sciencesExtracorporeal Membrane Oxygenation0302 clinical medicineExtracorporeal membrane oxygenationmedicineHumansanticoagulationOxygenatorRetrospective Studiesextracorporeal oxygenationHeparinbusiness.industryAnticoagulantAnticoagulantsThrombosisRetrospective cohort studyGeneral MedicineHeparinMiddle Agedunfractionated heparin030228 respiratory systemCoagulationAnesthesiaNadroparinnadroparinFemalebusinessmedicine.drugASAIO Journal
researchProduct

Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.

2014

Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…

AdultMalemedicine.medical_specialtyBiomedical EngineeringNormal DistributionHemodynamicsBiomaterialsInternal medicinePhotoplethysmogrammedicineHumansPhotoplethysmographyReactive hyperemiaHemodynamicsBlood flowArteriesmedicine.diseaseArterial occlusionAtomic and Molecular Physics and OpticsHealthy VolunteersElectronic Optical and Magnetic MaterialsFemoral Arterymedicine.anatomical_structureBlood pressureAnesthesiaCardiologyVascular resistanceArterial stiffnessFemaleVascular ResistanceJournal of biomedical optics
researchProduct

Biomechanical Determinants of Right Ventricular Failure in Pulmonary Hypertension.

2018

Pulmonary hypertension (PH) is a disease characterized by progressive adverse remodeling of the distal pulmonary arteries, resulting in elevated pulmonary vascular resistance and load pressure on the right ventricle (RV), ultimately leading to RV failure. Invasive hemodynamic testing is the gold standard for diagnosing PH and guiding patient therapy. We hypothesized that lumped-parameter and biventricular finite-element (FE) modeling may lead to noninvasive predictions of both PH-related hemodynamic and biomechanical parameters that induce PH. We created patient-specific biventricular FE models that characterize the biomechanical response of the heart and coupled them with a lumped-paramete…

AdultMalemedicine.medical_specialtyHypertension PulmonaryVentricular Dysfunction Right0206 medical engineeringFinite Element AnalysisBiomedical EngineeringBiophysicsCardiac indexHemodynamicsheart failureBioengineering02 engineering and technology030204 cardiovascular system & hematologyBiomaterialsContractility03 medical and health sciences0302 clinical medicineInternal medicineMedicineHumansInterventricular septumLead (electronics)business.industryGeneral MedicineMiddle Agedmedicine.disease020601 biomedical engineeringPulmonary hypertensionmedicine.anatomical_structureVentricleVascular resistanceCardiologyFemalebusinessASAIO journal (American Society for Artificial Internal Organs : 1992)
researchProduct

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Bone Marrow Concentrate and Bovine Bone Mineral for Sinus Floor Augmentation

2011

Purpose: The purpose of this work was to evaluate the potential of substituting autogenous bone (AB) by bone marrow aspirate concentrate (BMAC). Both AB and BMAC were tested in combination with a bovine bone mineral (BBM) for their ability of new bone formation (NBF) in a multicentric, randomized, controlled, clinical and histological noninferiority trial.Materials and Methods: Forty-five severely atrophied maxillary sinus from 26 patients were evaluated in a partial cross-over design. As test arm, 34 sinus of 25 patients were augmented with BBM and BMAC containing mesenchymal stem cells. Eleven control sinus from 11 patients were augmented with a mixture of 70% BBM and 30% AB. Biopsies wer…

AdultMalemedicine.medical_specialtySinus Floor AugmentationOSTEOGENIC DIFFERENTIATIONBone RegenerationMaxillary sinusBiomedical EngineeringSinus Floor AugmentationBioengineeringBiochemistryMAXILLARY SINUSlaw.inventionMESENCHYMAL STEM-CELLSBIO-OSSBiomaterialsRandomized controlled trialTISSUE-ENGINEERED BONEBone MarrowOsteogenesislawmedicineAnimalsHumansSingle-Blind MethodSinus (anatomy)AgedIMPLANT PLACEMENTHYDROXYAPATITE CERAMICSBone TransplantationIntention-to-treat analysisPOROUS HYDROXYAPATITEbusiness.industryIN-VITROMiddle AgedSurgeryAUTOGENOUS BONEImplant placementBovine bonemedicine.anatomical_structureBone SubstitutesCattleFemaleBone marrowbusinessTissue Engineering. Part A
researchProduct