Search results for "Biomedical engineering"

showing 10 items of 2020 documents

Truncation effects on muscular fatigue indexes based on M waves analysis

2012

International audience; In this paper, we investigate muscular fatigue. We propose a new fatigue index based on the continuous wavelet transform (CWT) and compare it with the standard fatigue indexes from literature. Fatigue indexes are all based on the electrical activity of muscles (electromyogram) acquired during an electrically stimulated contraction (ES). The stimulator and electromyogram system, which were presented in a previous work, allows real-time analysis. The extracted fatigue parameters are compared between each other and their sensitivity to noise is studied. The effect of truncation of M waves is then investigated, enlightening the robustness of the index obtained using CWT.

medicine.diagnostic_testElectromyographyAcousticsSpeech recognition0206 medical engineering02 engineering and technologyElectromyography020601 biomedical engineering[SPI.TRON] Engineering Sciences [physics]/Electronics[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/Electronics03 medical and health sciences0302 clinical medicineMuscular fatigueMuscle FatiguemedicineHumans030217 neurology & neurosurgeryContinuous wavelet transformMathematics
researchProduct

Multi axis representation and Euclidean distance of muscle fatigue indexes during evoked contractions

2014

International audience; In this article, we proposed a new representation of muscular fatigue during evoked muscle contractions based on fatigue indexes such as peak to peak amplitude, RMS of the M wave, mean and median frequency and fatigue index calculated from continuous wavelet transform (I CWT). These new representations of muscle fatigue using multi axis represented and Euclidean distance give better insights on changes in physiological characteristics during muscle fatigue. This technique provides a fatigue index using several muscle characteristics. The use of other kinds of fatigue characteristics as force could also be possible.

medicine.diagnostic_testMuscle fatigueSpeech recognitionMulti axis0206 medical engineeringMathematical analysis02 engineering and technologyElectromyography[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing020601 biomedical engineering[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEuclidean distance03 medical and health sciences0302 clinical medicineAmplitudeMuscular fatiguemedicineRepresentation (mathematics)[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing030217 neurology & neurosurgeryContinuous wavelet transform[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingMathematics
researchProduct

Optical Studies of the Capillary Refill Kinetics in Fingertips

2009

A new methodology for temporal analysis of the capillary refill processes by means of photoplethysmography (PPG) contact probe operating in the blue region of spectrum has been developed. A corresponding prototype device for finger measurements has been created and clinically tested. Results demonstrated that both AC and DC components of the blue PPG bio-signals are sensitive to the capillary occlusion and refill. Real-time measurements of the skin capillary refill kinetics by this technology can be used for noninvasive diagnostics of the peripheral perfusion disorders.

medicine.diagnostic_testPeripheral perfusionbusiness.industryCapillary actionPhotoplethysmogramKineticsmedicineSkin capillaryCapillary refillbusinessBiomedical engineering
researchProduct

Projection and Pinhole-Based Data Acquisition for Small-Animal SPECT Using Storage Phosphor Technology

2007

Three-dimensional Single Photon Emission Computed Tomography (SPECT) can provide high-resolution insight into biomolecular distribution and pharmacokinetics. However, instrument availability and distribution is limited at present,and imaging times can be considerable. To evaluate the large array of novel agents which are becoming available,we find that storage phosphor-based in vivo imaging can provide an important,rapid-throughput transition from the traditional ex vivo sacrifice/gamma counting and autoradiography to full-time course SPECT.

medicine.diagnostic_testPhotostimulated luminescenceComputer sciencebusiness.industryfungifood and beveragesSingle-photon emission computed tomographyData acquisitionSmall animalStorage phosphormedicinePinhole (optics)Projection (set theory)Nuclear medicinebusinessPreclinical imagingBiomedical engineering
researchProduct

2019

Ankle plantar flexor muscles are active in the stance phase of walking to propel the body forward. Increasing walking speed requires increased plantar flexor excitation, frequently assessed using surface electromyography (EMG). Despite its popularity, validity of surface EMG applied on shank muscles is mostly unclear. Thus, we examined the agreement between surface and intramuscular EMG at a range of walking speeds. Ten participants walked overground at slow, preferred, fast, and maximum walking speeds (1.01 ± 0.13, 1.43 ± 0.19, 1.84 ± 0.23, and 2.20 ± 0.38 m s-1, respectively) while surface and fine-wire EMG activities of flexor hallucis longus (FHL), soleus (SOL), medial gastrocnemius (MG…

medicine.diagnostic_testPhysiologyStance phase030229 sport sciencesElectromyographymusculoskeletal systemPlantar flexionbody regionsLeg musclePreferred walking speed03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureFlexor hallucis longusPhysiology (medical)medicineAnkle030217 neurology & neurosurgeryBiomedical engineeringLateral gastrocnemiusFrontiers in Physiology
researchProduct

Concentric force enhancement during human movement

2001

In order to understand the possible mechanisms contributing to enhanced concentric performance in stretch-shortening cycle exercises in vivo the present study examined knee extension torque, electromyogram (EMG) activity and fascicle length of the vastus lateralis muscle in maximal and submaximal human movements. Maximal concentric knee extensions (120 degrees s(-1)) were done after pre-stretch and pre-isometric conditions by nine volunteers. During shortening at the knee angle of 115 degrees (180 degrees = extended) the knee extension torque was found to be greater in pre-stretch condition (272 vs. 248 N m, P < 0.05) although the torque level prior to shortening was smaller than in pre-iso…

medicine.diagnostic_testPhysiologyVastus lateralis muscleElectromyographyAnatomyFascicleConcentricmedicine.disease_causeStretch shortening cycleJumpingmedicineEccentricmedicine.symptomBiomedical engineeringMuscle contractionMathematicsActa Physiologica Scandinavica
researchProduct

Tips and tricks for flow cytometry-based analysis and counting of microparticles

2015

Submicron-sized extra-cellular vesicles generated by budding from the external cell membranes, microparticles (MPs) are important actors in transfusion as well as in other medical specialties. After briefly positioning their role in the characterization of labile blood products, this technically oriented chapter aims to review practical points that need to be considered when trying to use flow cytometry for the analysis, characterization and absolute counting of MP subsets. Subjects of active discussions relative to instrumentation will include the choice of the trigger parameter, possible standardization approaches requiring instrument quality-control, origin and control of non-specific ba…

medicine.diagnostic_testPlasma samplesbusiness.industryHematologyLimitingFlow CytometryFlow cytometryCell-Derived MicroparticlesImmunologymedicineEnumerationAnimalsHumansInstrumentation (computer programming)businessBiomedical engineeringTransfusion and Apheresis Science
researchProduct

Optical biosensor-based characterization of anti-double-stranded DNA monoclonal antibodies as possible new standards for laboratory tests.

2009

The serum determination of circulating anti-double-stranded (ds)DNA autoantibodies is a routine measure for the laboratory diagnosis of systemic lupus erythematosus. Since available assays differ substantially and no feasible calibrator is available, the aim of this study was to evaluate a recently introduced surface plasmon resonance (SPR) biosensor chip for binding studies between dsDNA and anti-dsDNA autoantibodies and to demonstrate its usefulness for the characterization of new monoclonal antibody (mAb) standards and standardization of assays. We characterized two human and one murine monoclonal anti-dsDNA antibodies by measuring the kinetic on- and off-rates using the biosensor and ca…

medicine.drug_classBiomedical EngineeringBiophysicsElectrophoretic Mobility Shift AssayMonoclonal antibodyBinding Competitivechemistry.chemical_compoundMiceElectrochemistrymedicineAnimalsHumansLupus Erythematosus SystemicAviditySurface plasmon resonancebiologyChemistryAntibodies MonoclonalGeneral MedicineDNASurface Plasmon ResonanceMolecular biologyDissociation constantKineticsBiochemistryAntibodies AntinuclearMonoclonalbiology.proteinBinding Sites AntibodyAntibodyBiosensorDNABiotechnologyBiosensorsbioelectronics
researchProduct

Squaric Acid-Based Radiopharmaceuticals for Tumor Imaging and Therapy.

2021

Targeting vectors bound to a chelator represent a significant fraction of radiopharmaceuticals used nowadays for diagnostic and therapeutic purposes in nuclear medicine. The use of squaramides as coupling units for chelator and targeting vector helps to circumvent the disadvantages of several common coupling methods. This review gives an overview of the use of squaric acid diesters (SADE) as linking agents. It focuses on the conjugation of cyclic chelators, e.g., DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid), as well as hybrid chelators like AAZTA5 (6-pentanoic acid-6-amino-1,4-diazepine tetracetic acid) or DATA5m (6-pentanoic acid-6-amino-1,4-diazapine-triacetate) to diff…

medicine.drug_classBiomedical EngineeringPharmaceutical ScienceBioengineering02 engineering and technologySquaric acidMonoclonal antibody01 natural scienceschemistry.chemical_compoundFibroblast activation protein alphaIn vivoNeoplasmsmedicineDOTAHumansChelationPharmacology010405 organic chemistryChemistryOrganic Chemistry021001 nanoscience & nanotechnologyCombinatorial chemistrySmall molecule0104 chemical sciencesPositron-Emission TomographyRadiopharmaceuticals0210 nano-technologyCyclobutanesBiotechnologyConjugateBioconjugate chemistry
researchProduct

On the Use of XML in Medical Imaging Web-Based Applications

2016

The rapid growth of digital technology in medical fields over recent years has increased the need for applications able to manage patient medical records, imaging data, and chart information. Web-based applications are implemented with the purpose to link digital databases, storage and transmission protocols, management of large volumes of data and security concepts, allowing the possibility to read, analyze, and even diagnose remotely from the medical center where the information was acquired. The objective of this paper is to analyze the use of the Extensible Markup Language (XML) language in web-based applications that aid in diagnosis or treatment of patients, considering how this proto…

medicine.medical_specialty020205 medical informaticsComputer scienceSOAPcomputer.internet_protocolEfficient XML InterchangeProcessament electrònic de dadesBiomedical EngineeringBiophysicsWeb-based applications02 engineering and technologycomputer.software_genre030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine:Enginyeria química [Àrees temàtiques de la UPC]0202 electrical engineering electronic engineering information engineeringmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingWeb applicationComputational medicineComputingMilieux_MISCELLANEOUScomputer.programming_languageXHTMLInformation retrievalMultimedia[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryServeis webSearch engine indexingcomputer.file_formatXML frameworkXML languageDigital databasesSecuritybusinesscomputerWeb modelingXMLMedical InformaticsMedicina -- Informàtica
researchProduct