Search results for "Biomedical engineering"

showing 10 items of 2020 documents

Mass Output and Particle Size Distribution of Glucocorticosteroids Emitted from Different Inhalation Devices Depending on Various Inspiratory Paramet…

2002

Efficient inhalation therapy depends on successful delivery of the drug to the lung. The efficacy of drug delivery is not only influenced by the characteristics of the inhalation device, but also by the patient's handling of the device and by the inspiratory maneuver achieved through the device. We analyzed the output characteristics of three different chlorofluorocarbon (CFC)-free breath-actuated inhalers for inhaled glucocorticosteroids (BUD Turbohaler, FP Diskus/Accuhaler and HFA-BDP Autohaler, respectively). Mass output and particle size distribution of drug aerosol delivered by the inhalers were determined depending on different inhalation parameters in vitro using an Andersen cascade …

AdultPulmonary and Respiratory MedicineAnti-Inflammatory AgentsPulmonary Disease Chronic Obstructivechemistry.chemical_compoundAdministration InhalationHumansPharmacology (medical)Particle SizeBudesonideChildPeak flow meterLungmeasurement_unitAerosolsChlorofluorocarbonInhalationNebulizers and VaporizersInhalerBeclomethasoneAsthmaAerosolAndrostadienesInhalationchemistryVolume (thermodynamics)Anesthesiameasurement_unit.measuring_instrumentRespiratory MechanicsFluticasoneParticleParticle sizeBiomedical engineeringJournal of Aerosol Medicine
researchProduct

Complications of Poly Implant Prothèse breast implants: the current discussion

2013

Against the background of the current discussion about Poly Implant Prothèse (PIP, Seyne-sur-mer, France) breast implants, we want to present a case demonstrating the complications such as implant rupture, silicone dissemination and level III silicone lymphadenopathy. A 29-year-old woman with cosmetic breast augmentation with PIP implants 5 years previously showed a sensitive swelling in her right axilla and neck region. All tests to detect an infectious or lymphomatous lymphadenopathy were negative. After ultrasound and MRI, rupture of the right implant was assumed and multiple pathologically enlarged lymph nodes up to supraclavicular region were shown. An excision biopsy of one axillary l…

AdultReoperationmedicine.medical_specialtyAxillary lymph nodesBiopsyBreast ImplantsBiomedical EngineeringProsthesis DesignSilicone Gelschemistry.chemical_compoundSiliconeBiopsymedicineHumansBreast ImplantationLymphatic DiseasesBreast augmentationLymph nodeDevice Removalmedicine.diagnostic_testbusiness.industryForeign-Body ReactionGeneral MedicineProsthesis FailureSurgeryAxillaTreatment Outcomemedicine.anatomical_structurechemistryAxillaLymph Node ExcisionFemaleSurgeryLymph NodesLymphImplantbusinessExpert Review of Medical Devices
researchProduct

Mixed predictability and cross-validation to assess non-linear Granger causality in short cardiovascular variability series

2006

A method to evaluate the direction and strength of causal interactions in bivariate cardiovascular and cardiorespiratory series is presented. The method is based on quantifying self and mixed predictability of the two series using nearest-neighbour local linear approximation. It returns two causal coupling indexes measuring the relative improvement in predictability along direct and reverse directions, and a directionality index indicating the preferential direction of interaction. The method was implemented through a cross-validation approach that allowed quantification of directionality without constraining the embedding of the series, and fully exploited the available data to maximise th…

AdultStatistics as TopicBiomedical EngineeringInferenceBlood PressureHealth InformaticsBivariate analysisDirectionalityCross-validationGranger causalityHeart RateStatisticsEconometricsHumansComputer SimulationPredictabilityMathematicsSeries (mathematics)Models CardiovascularNonlinear systemNonlinear DynamicsData Interpretation StatisticalShort-term cardiovascular variabilityRespiratory MechanicsRegression AnalysisFemaleNon-linear predictionLinear approximationAlgorithmsBiomedizinische Technik/Biomedical Engineering
researchProduct

Phase information of time-frequency transforms as a key feature for classification of atrial fibrillation episodes

2015

[EN] Patients suffering from atrial fibrillation can be classified into different subtypes, according to the temporal pattern of the arrhythmia and its recurrence. Nowadays, clinicians cannot differentiate a priori between the different subtypes, and patient classification is done afterwards, when its clinical course is available. In this paper we present a comparison of classification performances when differentiating paroxysmal and persistent atrial fibrillation episodes by means of support vector machines. We analyze short surface electrocardiogram recordings by extracting modulus and phase features from several time-frequency transforms: short-time Fourier transform, Wigner-Ville, Choi-…

AdultSupport Vector MachineEXPRESION GRAFICA EN LA INGENIERIAPhysiologyBiomedical EngineeringBiophysicsPhase (waves)Sensitivity and SpecificityS-transform general Fourier-family transformCohort StudiesTertiary Care CentersElectrocardiographysymbols.namesakeText miningPhysiology (medical)Atrial FibrillationmedicineHumanscardiovascular diseasesAgedAged 80 and overPrincipal Component AnalysisFourier Analysisbusiness.industryCardiovascular AgentsAtrial fibrillationPattern recognitionMiddle Agedmedicine.diseaseAtrial fibrillationTime–frequency analysisSupport vector machineFourier transformROC CurveFeature (computer vision)Fourier analysisArea Under CurveTime-frequency transformsHypertensionsymbolsArtificial intelligenceMedical emergencybusiness
researchProduct

Time-Varying Surrogate Data to Assess Nonlinearity in Nonstationary Time Series: Application to Heart Rate Variability

2009

We propose a method to extend to time-varying (TV) systems the procedure for generating typical surrogate time series, in order to test the presence of nonlinear dynamics in potentially nonstationary signals. The method is based on fitting a TV autoregressive (AR) model to the original series and then regressing the model coefficients with random replacements of the model residuals to generate TV AR surrogate series. The proposed surrogate series were used in combination with a TV sample entropy (SE) discriminating statistic to assess nonlinearity in both simulated and experimental time series, in comparison with traditional time-invariant (TIV) surrogates combined with the TIV SE discrimin…

AdultTime FactorsComputer scienceRestBiomedical EngineeringSurrogate dataHeart RateStatisticsHumansHeart rate variabilityEntropy (information theory)Computer SimulationNonstationarityEntropy (energy dispersal)Time seriesEntropy (arrow of time)StatisticModels StatisticalEntropy (statistical thermodynamics)RespirationNonlinear dynamicModels CardiovascularComplexitySample entropyNonlinear systemNonlinear DynamicsAutoregressive modelSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaSurrogate dataTime-varying (TV) autoregressive (AR) modelHeart rate variability (HRV)AlgorithmsEntropy (order and disorder)IEEE Transactions on Biomedical Engineering
researchProduct

Photobleaching effects onin vivoskin autofluorescence lifetime

2015

The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …

AdultTime FactorsMaterials scienceLightPhotochemistryBiomedical EngineeringHuman skinAbsorption (skin)LipofuscinBiomaterialsNuclear magnetic resonanceFlavinsIntradermal NevusmedicineHumansNevusskin and connective tissue diseasesPhospholipidsSkinInflammationPhotobleachingbusiness.industryEquipment DesignMiddle AgedHandmedicine.diseasePhotobleachingFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsAutofluorescenceSpectrometry FluorescenceOxyhemoglobinsPicosecondFlavin-Adenine DinucleotideNevus IntradermalOptoelectronicsbusinessJournal of Biomedical Optics
researchProduct

Mechanical power test and fiber composition of human leg extensor muscles.

1983

The present study was undertaken to assess the relationship between the mechanical power developed during new anaerobic power test and muscular fiber distribution. Ten track and field male athletes were used as subjects, whose muscle fiber composition (m. vastus lateralis) varied from 25 to 58 fast twitch (FT) fibers. The test consisted of measuring the flight time with a special timer during 60 s continuous jumping. A formula was derived to allow the calculation of mechanical power during a certain period of time (e.g., in the present study every 15 s during 60 s of jumping performance). The relationship between the mechanical power for the first 15 s period correlated best with fast twitc…

AdultTime FactorsPhysiologymedicine.disease_causeSports MedicineJumpingPhysiology (medical)medicineHumansOrthopedics and Sports MedicineHuman legFiberMechanical energyMathematicsLegMusclesWork (physics)Public Health Environmental and Occupational HealthSkeletal muscleGeneral MedicineAnatomyBiomechanical Phenomenamedicine.anatomical_structureFiber compositionAnaerobic exerciseBiomedical engineeringEuropean journal of applied physiology and occupational physiology
researchProduct

EMG activity and voluntary activation during knee-extensor concentric torque generation

2002

This study was designed to re-examine and compare the neural drive of the knee extensors during isokinetic concentric muscular actions by means of the twitch interpolation technique (activation level, AL) and surface electromyographic (EMG) recordings (root mean square, RMS). Torque, AL and RMS amplitudes of three knee extensors and one knee flexor were measured in nine subjects during maximal and sub-maximal voluntary contractions, performed under concentric (60 degrees.s(-1) and 120 degrees.s(-1); Con60 and Con120, respectively) and isometric (Iso) conditions. Mean (SD) maximal voluntary torque was significantly lower ( P0.01) during concentric contractions [Con60: 208.6 (26.8) Nm and Con…

AdultVolitionKnee JointVastus medialisIsometric exerciseElectromyographyConcentricBicepsRoot mean squareIsometric ContractionPhysiology (medical)medicineHumansOrthopedics and Sports MedicinePhysicsmedicine.diagnostic_testElectromyographyPublic Health Environmental and Occupational HealthBiomechanicsMotor controlGeneral MedicineAnatomymusculoskeletal systemTorquehuman activitiesMuscle ContractionBiomedical engineeringEuropean Journal of Applied Physiology
researchProduct

Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic

1999

Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…

Adultmedicine.diagnostic_testVentricular functionComputer scienceDynamic dataMyocardial InfarctionMagnetic Resonance Imaging CineStroke VolumeMagnetic resonance imagingGeneral MedicineMiddle AgedFuzzy logicManual extractionFuzzy LogicImage Processing Computer-Assistedcardiovascular systemmedicineHumansVentricular FunctionRadiology Nuclear Medicine and imagingcardiovascular diseasesWall thicknessAgedBiomedical engineeringInvestigative Radiology
researchProduct

How to assess the risks associated with the usage of a medical device based on predictive modeling: the case of an anemia control model certified as …

2021

Background The successful application of Machine Learning (ML) to many clinical problems can lead to its implementation as medical devices (MD), being important to assess the associated risks. Methods An anemia control model (ACM), certified as MD may face adverse events as the result of wrong predictions that are translated into suggestions of doses of erythropoietic stimulating agents to dialysis patients. Risks are assessed as the combination of severity and probability of a given hazard. While severities are typically assessed by clinicians, probabilities are tightly related to the performance of the predictive model. Results A post-marketing dataset formed by all adult patients registe…

Adultmedicine.medical_specialtyAnemiabusiness.industryControl (management)Biomedical EngineeringAnemiaGeneral MedicineCertificationmedicine.diseaseHazardCohort StudiesMachine LearningRenal DialysisTest setCohortmedicineHematinicsHumansSurgeryIntensive care medicineAdverse effectRisk assessmentbusinessExpert review of medical devices
researchProduct