Influence of β-tricalcium phosphate granule size and morphology on tissue reaction in vivo.
2010
In this study the tissue reaction to five different β-tricalcium phosphate (β-TCP)-based bone substitute materials differing only in size, shape and porosity was analyzed over 60 days, at 3, 10, 15, 30 and 60 days after implantation. Using the subcutaneous implantation model in Wistar rats both the inflammatory response within the implantation bed and the resulting vascularization of the biomaterials were qualitatively and quantitatively assessed by means of standard and special histological staining methods. The data from this study showed that all investigated β-TCP bone substitutes induced the formation of multinucleated giant cells. Changes in size, shape and porosity influenced the int…
Robust Antigen-Specific T Cell Activation within Injectable 3D Synthetic Nanovaccine Depots
2021
Contains fulltext : 244693.pdf (Publisher’s version ) (Open Access) Synthetic cancer vaccines may boost anticancer immune responses by co-delivering tumor antigens and adjuvants to dendritic cells (DCs). The accessibility of cancer vaccines to DCs and thereby the delivery efficiency of antigenic material greatly depends on the vaccine platform that is used. Three-dimensional scaffolds have been developed to deliver antigens and adjuvants locally in an immunostimulatory environment to DCs to enable sustained availability. However, current systems have little control over the release profiles of the cargo that is incorporated and are often characterized by an initial high-burst release. Here,…
New insight into the genetics of age-related macular degeneration in connection with lipid metabolism
2010
Evaluation of: Zerbib J, Seddon JM, Richard F et al. rs5888 variant of SCARB1 gene is a possible susceptibility factor for age-related macular degeneration. PLoS ONE 4(10), e7341 (2009).Age-related macular degeneration (AMD) is the leading cause of visual loss in elderly populations of Western countries. According to demographic forecasts, and owing to the improvement in life expectancy, the number of people suffering from this pathology is expected to dramatically increase in the near future, thereby becoming a significant socioeconomic burden. There has been great progress in defining risk factors for AMD over the last few decades. Beyond advanced age, environmental and genetic factors ha…
A bioactive designer cytokine for human hematopoietic progenitor cell expansion
1997
Efficient expansion of hematopoietic progenitor cells requires, at least, the simultaneous stimulation of the receptors c-kit and gp130. While c-kit is activated by SCF; gp130, in cells which do not express sufficient amounts of IL-6R, can be activated by the complex of soluble IL-6R (sIL-6R) and IL-6. The therapeutic use of IL-6/sIL-6R, however, has been hampered by the high concentrations of the sIL-6R protein required. We have designed a fusion protein of sIL-6R and IL-6, linked by a flexible peptide chain, that was expressed to high levels. On gp130 expressing cells the fusion protein turned out to be fully active at 100 to 1,000-fold lower concentration than the combination of unlinked…
<title>A portable device for optical assessment of the cardiovascular condition</title>
2003
A hand-held prototype device for detection and processing of the tissue-remitted optical signals has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilation and contraction of skin blood vessels during the cardiac cycle. Cardiovascular condition of the monitored person was assessed by temporal analysis of the recorded PPG signals as well as by shape analysis of the mean single-period PPG signals.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
The automated assesment of artery hemodynamic parameters from ultrasound video
2012
The custom designed video processing software for analysis of B-mode and Doppler-mode ultrasound video has been proposed in this work. The software allows adjusting user-defined thresholds and tolerance levels to enhance contour detection in noisy and artifacted ultrasound images. The developed software is able to evaluate 16 hemodynamic parameters (artery diameter, pulse rate and flow velocity related parameters) in each cardiac cycle. The measurements were performed intermittently recording artery diameter (B-mode) and flow velocity (Doppler-mode). Software has validated in femoral artery measurements. The hemodynamic parameters computed by software were consistent with those obtained by …
Inverse estimation of terminal connections in the cardiac conduction system
2017
Modeling the cardiac conduction system is a challenging problem in the context of computational cardiac electrophysiology. Its ventricular section, the Purkinje system, is responsible for triggering tissue electrical activation at discrete terminal locations, which subsequently spreads throughout the ventricles. In this paper, we present an algorithm that is capable of estimating the location of the Purkinje system triggering points from a set of random measurements on tissue. We present the properties and the performance of the algorithm under controlled synthetic scenarios. Results show that the method is capable of locating most of the triggering points in scenarios with a fair ratio bet…
Adipose Stromal Vascular Fraction Improves Cardiac Function in Chronic Myocardial Infarction Through Differentiation and Paracrine Activity
2012
Fresh adipose-derived cells have been shown to be effective in the treatment of acute myocardial infarction (MI), but their role in the chronic setting is unknown. We sought to determine the long-term effect of the adipose derived-stromal vascular fraction (SVF) cell transplantation in a rat model of chronic MI. MI was induced in 82 rats by permanent coronary artery ligation and 5 weeks later rats were allocated to receive an intramyocardial injection of 107 GFP-expressing fresh SVF cells or culture media as control. Heart function and tissue metabolism were determined by echocardiography and 18F-FDG-microPET, respectively, and histological studies were performed for up to 3 months after t…
External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.
2007
Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…
Computed tomography detects changes in contrast agent diffusion after collagen cross-linking typical to natural aging of articular cartilage
2011
SummaryObjectiveThe effect of threose-induced collagen cross-linking on the mechanical and diffusive properties of cartilage was investigated in vitro. In particular, we investigated the potential of Contrast Enhanced Computed Tomography (CECT) to detect changes in articular cartilage after increased collagen cross-linking, which is an age-related phenomenon.MethodsOsteochondral plugs (Ø=6.0mm, n=28) were prepared from intact bovine patellae (n=7). Two of the four adjacent samples, prepared from each patella, were treated with threose to increase the collagen cross-linking, while the other two specimen served as paired controls. One sample pair was mechanically tested and then mechanically …