Search results for "Biomedical"
showing 10 items of 2328 documents
Tissue characterization of benign brain tumors: Use of NMR-tissue parameters
1988
Abstract To evaluate the potentials of NMR tissue parameters for tissue characterization we investigated 68 patients with benign brain tumors. Tissue parameters were accurately measured by a recently developed interlaced triple sequence. Each individual tumor was characterized by a set of three numbers (relaxation times T 1 and T 2 and proton density Rho). Different tumors exhibited significant overlaps of the three tissue parameters. Therefore a reliable prediction of the histological diagnosis based on the quantitative analysis of tissue parameters alone was not possible. T 2 -prolongation correlated well with water content and “regressive changes” in meningiomas and neuromas.
On the use of the electromechanical impedance technique for the assessment of dental implant stability: Modeling and experimentation
2014
We propose the electromechanical impedance technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. A three-dimensional finite element model of a transducer bonded to the abutment of a dental implant placed in a host bone site was created to simulate the progress of the tissue healing that occurs after surgery. The healing was modeled by changing the …
Signal Characteristics of EMG at Different Levels of Muscle Tension
1976
Electromyographic activity of m. rectus femoris at submaximal and maximal voluntary contractions was quantified by conventional integration technique and also be a more "qualitative" procedure of automated motor unit averaging and frequency spectrum analysis. By relating the EMG parameters to produced muscle tension it was observed that the integrated EMG increased in a slightly nonlinear fashion with the increase in muscle force. The other EMG variables also showed clear changes as a function of muscle tension. The averaged motor unit potential (AMUP) and its specific parameters (number of spikes, amplitude, rise time and amplitude-rise time ratio) showed such changes with muscle tension t…
P and R Wave Detection in Complete Congenital Atrioventricular Block
2009
Complete atrioventricular block (type III AVB) is characterized by an absence of P wave transmission to ventricles. This implies that QRS complexes are generated in an autonomous way and are not coordinated with P waves. This work introduces a new algorithm for the detection of P waves for this type of pathology using non-invasive electrocardiographic surface leads. The proposed algorithm is divided into three stages. In the first stage, the R waves located by a QRS detector are used to generate the RR series and time references for the other stages of the algorithm. In the second stage, the ventricular activity (QT segment) is removed by using an adaptive filter that obtains an averaged pa…
MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.
1991
A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choice in local radiation therapy planning of brain tumors.
Dosage individualization of erythropoietin using a profile-dependent support vector regression
2003
The external administration of recombinant human erythropoietin is the chosen treatment for those patients with secondary anemia due to chronic renal failure in periodic hemodialysis. The objective of this paper is to carry out an individualized prediction of the EPO dosage to be administered to those patients. The high cost of this medication, its side-effects and the phenomenon of potential resistance which some individuals suffer all justify the need for a model which is capable of optimizing dosage individualization. A group of 110 patients and several patient factors were used to develop the models. The support vector regressor (SVR) is benchmarked with the classical multilayer percept…
Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.
2013
Background: An important task in diabetes management is detection of hypoglycemia. Professional continuous glucose monitoring (CGM), which produces a glucose reading every 5 min, is a powerful tool for retrospective identification of unrecognized hypoglycemia. Unfortunately, CGM devices tend to be inaccurate, especially in the hypoglycemic range, which limits their applicability for hypoglycemia detection. The objective of this study was to develop an automated pattern recognition algorithm to detect hypoglycemic events in retrospective, professional CGM. Method: Continuous glucose monitoring and plasma glucose (PG) readings were obtained from 17 data sets of 10 type 1 diabetes patients und…
Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…
2015
Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…
Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla
2009
Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…
Assessment of normal patellar cartilage volume and thickness using MRI: an analysis of currently available pulse sequences.
1996
Objective. The objective of this study was to analyse the potential of magnetic resonance imaging for valid determination of patellar cartilage thickness, comparing currently available pulse sequences. Design. In six patients and one cadaver the cartilage was repetitively imaged employing three spin-echo and six three-dimensional gradient-echo sequences. In the cadaveric specimen the total volume and the regional distribution of cartilage thickness were assessed and compared with the values obtained from anatomical sections by image analysis. Results and conclusions. The FLASH and fat-suppressed FLASH sequences allowed the most accurate determination of the cartilage volume and thickness. F…