Search results for "Biomedical"

showing 10 items of 2328 documents

Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Cutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles

2016

International audience; Electronic textiles are an emerging field providing novel and non-intrusive solutions for healthcare. Conducting polymer-coated textiles enable a new generation of fully organic surface electrodes for electrophysiological evaluations. Textile electrodes are able to assess high quality muscular monitoring and to perform transcutaneous electrical stimulation.

AdultMalegradientsMaterials scienceBiomedical EngineeringPharmaceutical ScienceElectric Stimulation Therapy02 engineering and technology010402 general chemistry01 natural sciencesstimulationBiomaterialselectrochemical transistorexcitabilityHumansPEDOT:PSSneural interfacesMuscle activityMuscle SkeletalTextile electrodesElectrodespolymersmuscle activityElectromyographyTextiles[SCCO.NEUR]Cognitive science/Neurosciencepoly(3Transcutaneous Electrical Stimulationsmart textilereflex021001 nanoscience & nanotechnologyelectrophysiology0104 chemical sciencesmicroelectrode arrays[ SCCO.NEUR ] Cognitive science/Neurosciencenanoparticles4-ethylenedioxythiophene)0210 nano-technologyBiomedical engineering
researchProduct

Unfractionated Heparin Versus Subcutaneous Nadroparin in Adults Supported With Venovenous Extracorporeal Membrane Oxygenation: a Retrospective, Multi…

2021

Extracorporeal membrane oxygenation (ECMO) requires constant management of coagulation. Whereas unfractionated heparin remains the anticoagulant of choice, experienced centers report high bleeding rates. Biocompatibility of the extracorporeal circuit enables management of anticoagulation with subcutaneous low-molecular-weight heparins only. The aim of this study was to evaluate the safety and feasibility of anticoagulation with subcutaneous nadroparin compared with unfractionated heparin during respiratory ECMO in patients. We assessed for thrombotic complications and number of bleeding and life-threatening bleeding events. Additionally, we evaluated the change in resistance to flow in the …

AdultMalemedicine.drug_classmedicine.medical_treatmentBiomedical EngineeringBiophysicsBioengineering030204 cardiovascular system & hematologyExtracorporealBiomaterials03 medical and health sciencesExtracorporeal Membrane Oxygenation0302 clinical medicineExtracorporeal membrane oxygenationmedicineHumansanticoagulationOxygenatorRetrospective Studiesextracorporeal oxygenationHeparinbusiness.industryAnticoagulantAnticoagulantsThrombosisRetrospective cohort studyGeneral MedicineHeparinMiddle Agedunfractionated heparin030228 respiratory systemCoagulationAnesthesiaNadroparinnadroparinFemalebusinessmedicine.drugASAIO Journal
researchProduct

Piezosurgery in endoscopic dacryocystorhinostomy

2009

Piezosurgery is a recently developed system for cutting bone with microvibrations. The equipment consists of two hand pieces, two inserts, and two peristaltic pumps connected to the control unit. The device is endowed with an irrigation system of high-flow saline solution that breaks up into very small particles, with a “bloodless” effect on the surgical site and a low indirect thermal damage to the bone surfaces and adjacent structures. 4,5 The touch screen of the main unit permits selection of the specific insert, and modulation of the irrigation and the power according to the bone density. The device uses low-frequency ultrasonic waves (24.7-29.5 kHz), the applied power can be modulated …

AdultMalemedicine.medical_specialtyAdolescentUltrasonic TherapyElectrosurgeryControl unitPeristaltic pumpEndoscopic dacryocystorhinostomyCohort StudiesSurgical siteHumansMedicinePiezosurgeryAgedRetrospective StudiesInsert (composites)business.industryEndoscopyMiddle Agedpiezosurgery dacryocystorhinostomySurgerySettore MED/31 - OtorinolaringoiatriaTreatment OutcomeOtorhinolaryngologyFemaleSurgeryUltrasonic sensorThermal damagebusinessDacryocystorhinostomyBiomedical engineeringOtolaryngology–Head and Neck Surgery
researchProduct

Influence of age and sex on aortic distensibility assessed by MRI in healthy subjects

2010

International audience; Abstract: Magnetic resonance imaging (MRI) is particularly well adapted to the evaluation of aortic distensibility. The calculation of this parameter, based on the change in vessel cross-sectional area per unit change in blood pressure, requires precise delineation of the aortic wall on a series of cine-MR images. Firstly, the study consisted in validating a new automatic method to assess aortic elasticity. Secondly, aortic distensibility was studied for the ascending and descending thoracic aortas in 26 healthy subjects. Two homogeneous groups were available to evaluate the influence of sex and age (with an age limit value of 35 years). The automatic postprocessing …

AdultMalemedicine.medical_specialtyAgingPopulationBiomedical EngineeringBiophysics030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSex FactorsAutomatic processingmedicine.arteryInternal medicineElastic ModulusAscending aortaImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansRadiology Nuclear Medicine and imagingHealthy subjectseducationAortaAortaeducation.field_of_studymedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryMagnetic resonance imagingMagnetic Resonance ImagingElasticityBlood pressureDescending aortaCirculatory systemCardiologycardiovascular systemElasticity Imaging TechniquesAortic stiffnessFemaleRadiologybusinessMRI
researchProduct

Ventilatory threshold during incremental running can be estimated using EMG shorts

2012

The present study examined whether shorts with textile electromyographic (EMG) electrodes can be used to detect second ventilatory threshold (V(T2)) during incremental treadmill running. Thirteen recreationally active (REC) and eight endurance athletes were measured for EMG, heart rate, blood lactate and respiratory gases during VO(2max) test (3 min ramps, 1 km·h(-1) increments). V(T)(2), onset of blood lactate accumulation (OBLA) and EMG threshold (EMG(T)) were determined. In athletes, OBLA occurred at 56 ± 6 mL·kg(-1)·min(-1), V(T2) occurred at 59 ± 6 mL·kg(-1)·min(-1), and EMG(T) at 62 ± 6 mL·kg(-1)·min(-1) without significant differences between methods (analysis of variance: ANOVA). In…

AdultMalemedicine.medical_specialtyAnaerobic ThresholdPhysiologyLactic acid bloodBiomedical EngineeringBiophysicsRunningTreadmill runningPhysiology (medical)Internal medicineHeart rateBlood lactateHumansMedicineLactic AcidElectromyographybusiness.industryLimits of agreementAthletesPhysical EnduranceCardiologyPhysical therapyPulmonary VentilationVentilatory thresholdbusinessPhysiological Measurement
researchProduct

Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.

2014

Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…

AdultMalemedicine.medical_specialtyBiomedical EngineeringNormal DistributionHemodynamicsBiomaterialsInternal medicinePhotoplethysmogrammedicineHumansPhotoplethysmographyReactive hyperemiaHemodynamicsBlood flowArteriesmedicine.diseaseArterial occlusionAtomic and Molecular Physics and OpticsHealthy VolunteersElectronic Optical and Magnetic MaterialsFemoral Arterymedicine.anatomical_structureBlood pressureAnesthesiaCardiologyVascular resistanceArterial stiffnessFemaleVascular ResistanceJournal of biomedical optics
researchProduct

Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

2011

International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…

AdultMalemedicine.medical_specialtyBiomedical Engineering[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030204 cardiovascular system & hematologyCardiography Impedance03 medical and health sciencesVascular Stiffness0302 clinical medicineNuclear magnetic resonanceInternal medicinemedicine.arterymedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansPulse wave velocityAortaAgedAortamedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryModels CardiovascularSignal Processing Computer-AssistedMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingComputer Science ApplicationsImpedance cardiographyDragCardiologyArterial stiffnessFemaleAortic stiffnessElectrophysiologic Techniques CardiacbusinessBioelectrical impedance analysisAlgorithms030217 neurology & neurosurgery
researchProduct

Biceps brachii muscle oxygenation in electrical muscle stimulation

2010

The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contrac…

AdultMalemedicine.medical_specialtyContraction (grammar)PhysiologyElectrical muscle stimulationmedicine.medical_treatmentElbowHemodynamicsBlood volumeIsometric exerciseOxidative MetabolismBicepsUpper ExtremityHemoglobinsYoung AdultOxygen ConsumptionIsometric ContractionPhysiology (medical)Internal medicineVoluntary ContractionsmedicineHumansMuscle SkeletalSpectroscopy Near-InfraredBlood Volumebusiness.industryNear-Infrared SpectroscopyGeneral MedicineOxygenationAnatomy090300 BIOMEDICAL ENGINEERINGElectric Stimulation111600 MEDICAL PHYSIOLOGYOxygenmedicine.anatomical_structureTorque110600 HUMAN MOVEMENT AND SPORTS SCIENCEOxyhemoglobinsCardiologyNeuromuscular Electrical StimulationbusinessIndraStra Global
researchProduct

Gabor frames for classification of paroxysmal and persistent atrial fibrillation episodes

2016

[EN] In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days. Today, clinicians provide patients classification once the course of the arrhythmia has been disclosed. This classification problem is dealt with in this study. We study a sparse representation of surface electrocardiogram signals by means of Gabor frames and afterwards we apply a linear discriminant analysis. Thus, we provide an early discrimination, obtaining promising…

AdultMalemedicine.medical_specialtyEXPRESION GRAFICA EN LA INGENIERIAmedicine.medical_treatment0206 medical engineeringBiomedical EngineeringBiophysicsCatheter ablation02 engineering and technology030204 cardiovascular system & hematologyPharmacological treatmentElectrocardiography03 medical and health sciences0302 clinical medicineInternal medicineHumansMedicineSinus rhythmAgedAged 80 and overbusiness.industrySignal Processing Computer-AssistedAtrial fibrillationMiddle Agedmedicine.diseaseLinear discriminant analysisAtrial fibrillation020601 biomedical engineeringElectrocardiogramPersistent atrial fibrillationCohortCatheter AblationCardiologyClassification methodsFemaleGabor framesbusinessMedical Engineering & Physics
researchProduct