Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study

2016

Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …

AdultMalemedicine.medical_specialtyPlasma GasesPlasma cleaninghistologic analysisGingivaAbutmentStatistical differenceDental Abutments02 engineering and technology03 medical and health sciences0302 clinical medicineDouble-Blind MethodBiopsyCell Adhesionmedicineplasma of argonHumansArgonCell adhesionperi-implant soft tissue responseAgedscanning electronic microscopemedicine.diagnostic_testdental abutment histologic analysis peri-implant soft tissue response plasma of argon scanning electronic microscopeChemistrySoft tissue030206 dentistryMiddle Aged021001 nanoscience & nanotechnologySurgeryDental Prosthesis DesignHomogeneousCoronal planedental abutmentFemaleOral Surgery0210 nano-technologyBiomedical engineeringClinical Oral Implants Research
researchProduct

3D characterisation of the dynamics of foot joints of adults during walking. Gait pattern identification

2017

A detailed description of the kinematics and kinetics of the ankle, midtarsal and metatarsophalangeal joints of the feet of a healthy adult male population during barefoot walking is provided. Plots of the angles and moments in each plane during the stance phase are reported, along with the mean and standard deviation values of 87 different parameters that characterise the 3D dynamics of the foot joints. These parameters were used to check for similarities between subjects through a hierarchical analysis that allowed three different gait patterns to be identified, most of the differences corresponding to the frontal and transverse planes.

AdultMalemedicine.medical_specialtyPopulationBiomedical EngineeringMetatarsophalangeal jointsBioengineeringKinematicsStandard deviation03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationImaging Three-DimensionalFiducial MarkersFoot JointsmedicineCluster AnalysisHumansgait patternseducationGaitMathematicseducation.field_of_studyDynamics (mechanics)030229 sport sciencesGeneral MedicineAnatomydynamicsfoot jointsGaitComputer Science ApplicationsBiomechanical PhenomenaHuman-Computer InteractionTransverse planemedicine.anatomical_structurekinematicskineticsAnkle030217 neurology & neurosurgery
researchProduct

Bone Marrow Concentrate and Bovine Bone Mineral for Sinus Floor Augmentation

2011

Purpose: The purpose of this work was to evaluate the potential of substituting autogenous bone (AB) by bone marrow aspirate concentrate (BMAC). Both AB and BMAC were tested in combination with a bovine bone mineral (BBM) for their ability of new bone formation (NBF) in a multicentric, randomized, controlled, clinical and histological noninferiority trial.Materials and Methods: Forty-five severely atrophied maxillary sinus from 26 patients were evaluated in a partial cross-over design. As test arm, 34 sinus of 25 patients were augmented with BBM and BMAC containing mesenchymal stem cells. Eleven control sinus from 11 patients were augmented with a mixture of 70% BBM and 30% AB. Biopsies wer…

AdultMalemedicine.medical_specialtySinus Floor AugmentationOSTEOGENIC DIFFERENTIATIONBone RegenerationMaxillary sinusBiomedical EngineeringSinus Floor AugmentationBioengineeringBiochemistryMAXILLARY SINUSlaw.inventionMESENCHYMAL STEM-CELLSBIO-OSSBiomaterialsRandomized controlled trialTISSUE-ENGINEERED BONEBone MarrowOsteogenesislawmedicineAnimalsHumansSingle-Blind MethodSinus (anatomy)AgedIMPLANT PLACEMENTHYDROXYAPATITE CERAMICSBone TransplantationIntention-to-treat analysisPOROUS HYDROXYAPATITEbusiness.industryIN-VITROMiddle AgedSurgeryAUTOGENOUS BONEImplant placementBovine bonemedicine.anatomical_structureBone SubstitutesCattleFemaleBone marrowbusinessTissue Engineering. Part A
researchProduct

Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally m…

2006

A causal approach to the calculation of coherence and transfer function between systolic pressure (SP) and RR interval variability was applied in eight patients and eight control subjects during prolonged tilt test for investigating the impairment of cardiovascular control related to neurally mediated syncope. The causal analysis showed a depressed baroreflex regulation in resting patients, with reduced gain and increased latency from SP to RR, and a drop of the baroreflex coupling immediately before syncope. These findings, which were not elicited by traditional cross-spectral analysis, strongly suggest the use of the causal approach for the study of syncope mechanisms. © 2006 IEEE.

AdultMalemedicine.medical_specialtyStatistics as TopicBiomedical EngineeringBlood PressureNeurally-mediated syncopeCardiovascular controlBaroreflexCardiovascular SystemSensitivity and SpecificitySeverity of Illness IndexFeedbackElectrocardiographyHeart RateInternal medicineSeverity of illnessHeart rateSyncope VasovagalmedicineHumansComputer SimulationDiagnosis Computer-AssistedModels Statisticalmedicine.diagnostic_testbusiness.industryTransfer functionModels CardiovascularReproducibility of ResultsBaroreflexBlood pressureData Interpretation StatisticalAnesthesiaCardiologyRegression AnalysisFemalebusinessElectrocardiographyCoherenceAlgorithmsSyncope (phonology)
researchProduct

Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial Experiences

2003

Purpose To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T (2)-weighted TSE with and w…

AdultMalemedicine.medical_specialtyTime FactorsAdolescentImage qualityKnee InjuriesSensitivity and SpecificityFractures BoneMusculoskeletal disordermedicineHumansRadiology Nuclear Medicine and imagingDetection theoryAnkle InjuriesChildAgedSensitivity encodingAged 80 and overMusculoskeletal imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFemoral Neck FracturesSurgerymedicine.anatomical_structureElectromagnetic coilFeasibility StudiesFemaleAnklebusinessAlgorithmsHip InjuriesBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Results of the performance verification of the CoaguChek XS system.

2008

Abstract Background This is the first paper reporting a performance verification study of a point-of-care (POC) monitor for prothrombin time (PT) testing according to the requirements given in chapter 8 of the International Organization for Standardization (ISO) 17593:2007 standard “Clinical laboratory testing and in vitro medical devices — Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy”. The monitor under investigation was the new CoaguChek XS system which is designed for use in patient self testing. Its detection principle is based on the amperometric measurement of the thrombin activity generated by starting the coagulation cascade using a rec…

AdultMalemedicine.medical_specialtyTime FactorsCoefficient of variationPoint-of-Care SystemsThromboplastinYoung AdultCoagulation cascadeAcceptance testingReference ValuesmedicineHumansIn patientInternational Normalized RatioBlood testingBlood CoagulationOral anticoagulationAgedReagent StripsProthrombin timeAged 80 and overmedicine.diagnostic_testbusiness.industryAnticoagulantsHematologyMiddle AgedRecombinant ProteinsSurgerySelf CareOral anticoagulantProthrombin TimeFemaleDrug MonitoringbusinessBiomedical engineeringThrombosis research
researchProduct

Effects of fatigue on isometric force- and relaxation-time characteristics in human muscle

1981

Effects of intermittent one leg isometric fatigue on maximal isometric force, force production, relaxation and blood lactate were studied using 29 male students as subjects. The relative changes of variables during fatigue and recovery were intercorrelated together with muscle structure variables, which were determined using needle biopsy technique. Maximal force decreased, force production and relaxation became slower and muscle lactate increased during fatigue. Change of maximal force, force production and lactate during fatigue as well as recovery of maximal force and lactate after fatigue were correlated significantly to muscle fiber distribution. Fatiguability of the force-time charact…

AdultMalemedicine.medical_specialtyTime FactorsPhysiologyChemistryMuscle RelaxationMusclesRelaxation (NMR)Isometric exerciseMuscle relaxationPhysical medicine and rehabilitationHuman muscleIsometric ContractionLactatesmedicineBlood lactateHumansFatiguabilitymedicine.symptomMuscle fibreFatigueMuscle ContractionBiomedical engineeringMuscle contractionActa Physiologica Scandinavica
researchProduct

Association between physiological stress and skin temperature response after a half marathon

2019

OBJECTIVE: The objective of this study was to determine the association between skin temperature response and the physiological stress after a half marathon. APPROACH: Seventeen runners were measured 48 h before, 24 h before, 24 h after and 48 h after completing a half marathon. The measurements on each day of testing included blood markers (creatine kinase [CK] and glutamate oxaloacetate transaminase [GOT]), perception of pain and fatigue (using a visual analogue scale), skin temperature (using infrared thermography), and jump performance (using countermovement jump test). MAIN RESULTS: CK (p     1.0) increased 24 h after the half marathon, whereas jump performance decreased (p   <  0.01 a…

AdultMalemedicine.medical_specialtyTime FactorsPhysiologyVisual analogue scale0206 medical engineeringBiomedical EngineeringBiophysics02 engineering and technologyRunning03 medical and health sciencesBasal (phylogenetics)0302 clinical medicineStress PhysiologicalPhysiology (medical)Internal medicineHumansMedicineBlood markersFatiguePhysiological stressEsportsbiologybusiness.industryFatigaSkin temperaturePain PerceptionGlutamate oxaloacetate transaminase020601 biomedical engineeringbiology.proteinCountermovement jumpCardiologyFemaleCreatine kinaseSkin Temperaturebusiness030217 neurology & neurosurgery
researchProduct

Comparative, validity and responsiveness of the HOOS-PS and KOOS-PS to the WOMAC physical function subscale in total joint replacement for Osteoarthr…

2009

Udgivelsesdato: 2009-Jul OBJECTIVE: To evaluate the internal consistency of the Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS) and the Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS) in total hip replacement (THR) and total knee (TKR) replacement. Construct validity and responsiveness were compared to the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) Likert 3.0 physical function (PF) subscale and the PF excluding the items in the short measures (PF-exclusions). METHODS: Participants completed the full HOOS or KOOS, measures of fatigue, anxiety, depression and the Chronic Pain Grade (CPG) pre-su…

AdultMalemedicine.medical_specialtyWOMACmedicine.medical_treatmentArthroplasty Replacement HipBiomedical EngineeringOsteoarthritisAnxietySeverity of Illness IndexOsteoarthritis HipValidity03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationRheumatologyCronbach's alphaSeverity of illnessActivities of Daily LivingmedicineHumansOrthopedics and Sports MedicineDisabled PersonsArthroplasty Replacement KneeHOOS-PSFatigueTotal joint replacementAgedPain Measurement030203 arthritis & rheumatologyAged 80 and over030222 orthopedicsDepressive Disorderbusiness.industryChronic painConstruct validityResponsivenessMiddle AgedOsteoarthritis Kneemedicine.diseaseKOOS-PSArthroplastyArthralgiaWOMACPhysical therapyAnxietyFemalemedicine.symptombusinessOsteoarthritis and Cartilage
researchProduct

Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes

2013

Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…

AdultMalemedicine.medical_specialtyambulatory electrocardiographyBiomedical EngineeringBiophysicsElectrocardiographyYoung Adultevaluation studiesmedicineHumansWirelessMedical physicscardiovascular diseasesChildReference standardsAgedAmbulatory electrocardiographySensor systemclinical trialsbusiness.industryReproducibility of ResultsArrhythmias CardiacSignal Processing Computer-AssistedVDP::Technology: 500::Information and communication technology: 550Middle AgedReference StandardsHolter monitoringClinical trialVDP::Medical disciplines: 700wireless ECG sensorFemalebusinessTelecommunicationsWireless TechnologyClinical evaluationHolter monitoring
researchProduct