Search results for "Biomedical"

showing 10 items of 2328 documents

Kinematics and electromyographic activity of horse riders during various cross-country jumps in equestrian

2019

International audience; The objective of this study was to identify the key biomechanical patterns (functional muscles and kinematics) of amateur horse riders during various cross-country jumps in equestrian. Eleven riders first performed a control condition that corresponded to jumps over three different obstacles (log wall, brush and tree trunk) before jumping over the same three obstacles in a cross-country course. 3D Kinematics and electromyographic (EMG) activity was synchronously collected which included seven muscles of the riders back, lower and upper limbs. Maximum voluntary isometric strength of knee extensors was also measured before and immediately after the race to investigate …

AdultMalemedicine.medical_specialtycontractileAdolescentKnee Jointneuromuscular fatigueMovement0206 medical engineeringwarmPhysical Therapy Sports Therapy and Rehabilitation02 engineering and technologyKinematicsIsometric exercisemuscle activation intervalsmedicine.disease_cause03 medical and health sciencesYoung AdultMotion0302 clinical medicineJumpingLower bodyPhysical medicine and rehabilitationhorse ridersmedicineAnimalsHumansOrthopedics and Sports MedicineHorsesMuscle SkeletalCross countryKnee extensorsElectromyographyHorse030229 sport sciences020601 biomedical engineeringBiomechanical PhenomenaMuscle FatigueFemaleactivationfatigue[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Psychologyperformance3d kinematicsSports
researchProduct

Epidemiology of hepatitis C virus infection in hemodialysis patients of Sicily

2008

AdultMalemedicine.medical_specialtymedicine.medical_treatmentHepatitis C virusBiomedical EngineeringMedicine (miscellaneous)BioengineeringHepacivirusmedicine.disease_causeBiomaterialsYoung AdultRenal DialysisEpidemiologymedicinePrevalenceHumansSicilyAgedAged 80 and overbusiness.industryGeneral MedicineHepatitis C AntibodiesHepatitis C ChronicMiddle AgedViral LoadVirologyChronic DiseaseRNA ViralFemaleKidney DiseasesHemodialysisbusiness
researchProduct

Biomechanical Loading of Achilles Tendon During Normal Locomotion

1992

Direct in vivo Achilles tendon force measurements open up new possibilities for understanding the loading of the Achilles tendon during natural locomotion. This article describes how these human experiments can be performed. The results of these experiments imply that Achilles tendon forces are unexpectedly high in certain activities (e.g., hopping) and that the rates of loading rather than the absolute magnitudes of the recorded forces may be more relevant for clinical purposes as well as for the construction of artificial tendon materials.

AdultMalemusculoskeletal diseasesAchilles tendonTendo Calcaneusbusiness.industryTransducersBiomechanicsPhysical Therapy Sports Therapy and RehabilitationWalkingAnatomymusculoskeletal systemAchilles TendonBicyclingBiomechanical PhenomenaRunningBiomechanical PhenomenaTendonmedicine.anatomical_structureHumansMedicineOrthopedics and Sports MedicinebusinessLocomotionBiomedical engineeringClinics in Sports Medicine
researchProduct

Which muscles compromise human locomotor performance with age?

2014

Ageing leads to a progressive decline in human locomotor performance. However, it is not known whether this decline results from reduced joint moment and power generation of all lower limb muscle groups or just some of them. To further our understanding of age-related locomotor decline, we compare the amounts of joint moments and powers generated by lower limb muscles during walking (self-selected), running (4 m s −1 ) and sprinting (maximal speed) among young, middle-aged and old adults. We find that age-related deficit in ankle plantarflexor moment and power generation becomes more severe as locomotion change from walking to running to sprinting. As a result, old adults generate more pow…

AdultMalemusculoskeletal diseasesAgingmedicine.medical_specialtyBiomedical EngineeringBiophysicsBioengineeringWalkingKnee JointBiochemistryRunningBiomaterialsLower limb muscleHumansMedicineMuscle StrengthYoung adultMuscle SkeletalResearch ArticlesAgedAged 80 and overbusiness.industryJoint momentBiomechanicsMiddle AgedGaitmedicine.anatomical_structureAgeingPhysical therapyHip JointAnkleAnklebusinesshuman activitiesBiotechnologyJournal of The Royal Society Interface
researchProduct

In vivo muscle mechanics during locomotion depend on movement amplitude and contraction intensity

2001

The effects of movement amplitude and contraction intensity on triceps surae and quadriceps femoris muscle function were studied during repetitive hopping. In vivo forces from Achilles and patellar tendons were recorded with the optic fibre technique from eight volunteers. The performances were filmed (200 Hz) to determine changes in muscle-tendon unit length and velocity. When hopping with a small amplitude (23 degrees knee flexion during the ground contact phase), the Achilles tendon was primarily loaded whereas patellar tendon forces were greater in large-amplitude hopping (56 degrees knee flexion). In spite of the different magnitudes of stretch in the quadriceps femoris muscle, the str…

AdultMalemusculoskeletal diseasesMaterials scienceKnee JointPhysiologyMovementmedicine.disease_causeAchilles TendonGastrocnemius muscleJumpingTriceps surae musclePhysiology (medical)medicineFiber Optic TechnologyHumansOrthopedics and Sports MedicineMuscle SkeletalAchilles tendonElectromyographyPublic Health Environmental and Occupational HealthBody movementPatellaGeneral MedicineAnatomymusculoskeletal systemQuadriceps femoris muscleBiomechanical PhenomenaTendonmedicine.anatomical_structureFemalemedicine.symptomLocomotionMuscle ContractionBiomedical engineeringMuscle contractionEuropean Journal of Applied Physiology
researchProduct

Estimation of Muscular Fatigue under Electromyostimulation Using CWT

2012

International audience; The aims of this study are to investigate muscular fatigue and to propose a new fatigue index based on the continuous wavelet transform (CWT) which is compared to the standard fatigue indexes from literature. Fatigue indexes are all based on the electrical activity of muscles (electromyogram) acquired during an electrically stimulated contraction thanks to two modules (electromyostimulation + electromyography recording) that can analyze EMG signals in real time during electromyostimulation. The extracted parameters are compared with each other and their sensitivity to noise is studied. The effect of truncation of M waves is then investigated, enlightening the robustn…

AdultMaletruncationwavelet.Acoustics0206 medical engineeringBiomedical EngineeringWavelet Analysis02 engineering and technologyElectromyography03 medical and health sciences0302 clinical medicineWaveletwaveletmedicineHumansContinuous wavelet transformMathematicsMuscle fatiguemedicine.diagnostic_testMuscle fatigueElectromyographyBiomechanicsWavelet transform020601 biomedical engineering[SPI.TRON] Engineering Sciences [physics]/ElectronicsElectric StimulationElectromyogram[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsForearmMuscular fatigueArmElectromyostimulation030217 neurology & neurosurgeryBiomedical engineering
researchProduct

Confocal microscopy: a valid approach to evaluate the three-dimensional characteristics of root-end cavities

2013

Objective: To analyze, using confocal microscope, the three-dimensional characteristics of the root-end cavity preparations completed in root apices of extracted teeth determining their area, perimeter, circularity and cavo-surface angle. Study design: Thirty-two single-rooted extracted teeth underwent endodontic treatment and apical resection. Root-end cavities were prepared according to 4 protocols, as follows: Group1, stainless steel ultrasonic tips (SST) at 33 KHz power; Group 2, SST at 30 KHz power; Group 3, diamond-coated ultrasonic tips (DCT) at 30 KHz power; and Group 4, DCT at 33 KHz power. Finally, root-end cavity was evaluated using a confocal microscope, recording its area, peri…

AdultMaterials scienceMicroscopeAdolescentConfocalOdontologíaIn Vitro TechniquesEndodonticslaw.inventionResectionUltrasonic tipsPerimeterYoung AdultTooth rootConfocal microscopylawMicroscopyHumansTooth RootGeneral DentistryMicroscopy ConfocalAnatomyMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludConfocal microscopyOtorhinolaryngologySurgical root canal treatmentUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryUltrasonic sensorRoot-end cavityRoot Canal PreparationBiomedical engineering
researchProduct

Relationship between electrical and mechanical properties of motor units.

1990

In six healthy volunteers, the size of the motor unit action potential (MUAP) was related to its contractile behaviour. Electrical activity was determined by measuring amplitude and area of the potential, using the macro electromyography (EMG) technique. The mechanical response was characterised by contraction time, twitch force and relaxation time, recorded with the spike triggered averaging technique. With increasing tension of the whole muscle corresponding to an increasing threshold, the force of single units enlarged exponentially compared to their EMG. There was only a weak relationship between contraction time and electrical activity and none between EMG and relaxation time.

AdultMaterials scienceMuscle RelaxationAction PotentialsElectromyographymedicineHumansMotor Neuronsmedicine.diagnostic_testTension (physics)ElectromyographyMusclesBiomechanicsAnatomyMiddle AgedBiomechanical PhenomenaMotor unitPsychiatry and Mental healthElectrophysiologyAmplitudeMuscle relaxationSurgeryNeurology (clinical)medicine.symptomMuscle contractionBiomedical engineeringMuscle ContractionResearch ArticleJournal of neurology, neurosurgery, and psychiatry
researchProduct

Multimodal Device for Real-Time Monitoring of Skin Oxygen Saturation and Microcirculation Function

2019

The present study introduces a recently developed compact hybrid device for real-time monitoring of skin oxygen saturation and temperature distribution. The prototype involves a snapshot hyperspectral camera, multi-wavelength illuminator, thermal camera, and built-in computer with custom-developed software. To validate this device in-vivo we performed upper arm vascular occlusion on eight healthy volunteers. Palm skin oxygen saturation maps were analyzed in real-time using k-means segmentation algorithm and two-layer optical diffuse model. The prototype system demonstrated a satisfying performance of skin hyperspectral measurements in the spectral range of 507&ndash

AdultMaterials sciencehyperspectral imaginglcsh:BiotechnologyClinical BiochemistryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONmicrocirculationmultimodal imaging02 engineering and technologyProof of Concept Study01 natural sciencesskin mottlingArticleMicrocirculation010309 opticsSoftwarelcsh:TP248.13-248.650103 physical sciencesHealthy volunteersHumansSegmentationMonitoring PhysiologicSkinHemoglobin SaturationMultimodal imagingHybrid devicebusiness.industryTemperatureHyperspectral imagingGeneral Medicine021001 nanoscience & nanotechnologyOxygenskin oxygen saturation0210 nano-technologybusinessBiomedical engineeringBiosensors
researchProduct

The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait

2021

Background Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. Research question What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? Methods 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortab…

AdultMedial gastrocnemiusBiophysicslihaksetCHILDRENWalkingAchilles TendonStandard deviationjänteetGait (human)Dynamic ultrasoundMedicine and Health SciencesHumansMedicineOrthopedics and Sports MedicineliikeanalyysiLower limb muscle-tendonMuscle SkeletalGaitReliability (statistics)Ultrasonographyreliabiliteettibusiness.industryUltrasoundRehabilitationReproducibility of ResultsReliabilityjalatTendonkävelymittausmenetelmätPreferred walking speedmedicine.anatomical_structureGait analysisaskeleetultraäänitutkimusGait analysisbiomekaniikkabusinessWALKINGBiomedical engineering
researchProduct