Search results for "Biomedical"
showing 10 items of 2328 documents
Time-Varying Surrogate Data to Assess Nonlinearity in Nonstationary Time Series: Application to Heart Rate Variability
2009
We propose a method to extend to time-varying (TV) systems the procedure for generating typical surrogate time series, in order to test the presence of nonlinear dynamics in potentially nonstationary signals. The method is based on fitting a TV autoregressive (AR) model to the original series and then regressing the model coefficients with random replacements of the model residuals to generate TV AR surrogate series. The proposed surrogate series were used in combination with a TV sample entropy (SE) discriminating statistic to assess nonlinearity in both simulated and experimental time series, in comparison with traditional time-invariant (TIV) surrogates combined with the TIV SE discrimin…
Photobleaching effects onin vivoskin autofluorescence lifetime
2015
The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …
Mechanical power test and fiber composition of human leg extensor muscles.
1983
The present study was undertaken to assess the relationship between the mechanical power developed during new anaerobic power test and muscular fiber distribution. Ten track and field male athletes were used as subjects, whose muscle fiber composition (m. vastus lateralis) varied from 25 to 58 fast twitch (FT) fibers. The test consisted of measuring the flight time with a special timer during 60 s continuous jumping. A formula was derived to allow the calculation of mechanical power during a certain period of time (e.g., in the present study every 15 s during 60 s of jumping performance). The relationship between the mechanical power for the first 15 s period correlated best with fast twitc…
EMG activity and voluntary activation during knee-extensor concentric torque generation
2002
This study was designed to re-examine and compare the neural drive of the knee extensors during isokinetic concentric muscular actions by means of the twitch interpolation technique (activation level, AL) and surface electromyographic (EMG) recordings (root mean square, RMS). Torque, AL and RMS amplitudes of three knee extensors and one knee flexor were measured in nine subjects during maximal and sub-maximal voluntary contractions, performed under concentric (60 degrees.s(-1) and 120 degrees.s(-1); Con60 and Con120, respectively) and isometric (Iso) conditions. Mean (SD) maximal voluntary torque was significantly lower ( P0.01) during concentric contractions [Con60: 208.6 (26.8) Nm and Con…
Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic
1999
Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…
Changes in inflammation markers after a 10-week high-intensity combined strength and endurance training block in women: The effect of hormonal contra…
2019
Abstract Objectives The influence of hormonal contraceptives (HC) on inflammation and body composition after high-intensity combined strength and endurance training was investigated. Design Active healthy women formed two training groups: HC users (HCU, n = 9) and those who had never used HC (NHC, n = 9). Training included two strength training sessions and two high-intensity interval training sessions per week for 10 weeks. Methods Before (PRE) and after (POST) the training intervention, high-sensitivity C-reactive protein (hs-CRP), tumor necrosis factor alpha (TNF-α), interleukin-6 (IL-6), and interleukin-1beta (IL-1β) concentrations were measured. Dual-energy X-ray absorptiometry was use…
How to assess the risks associated with the usage of a medical device based on predictive modeling: the case of an anemia control model certified as …
2021
Background The successful application of Machine Learning (ML) to many clinical problems can lead to its implementation as medical devices (MD), being important to assess the associated risks. Methods An anemia control model (ACM), certified as MD may face adverse events as the result of wrong predictions that are translated into suggestions of doses of erythropoietic stimulating agents to dialysis patients. Risks are assessed as the combination of severity and probability of a given hazard. While severities are typically assessed by clinicians, probabilities are tightly related to the performance of the predictive model. Results A post-marketing dataset formed by all adult patients registe…
Assessment of haemophilic arthropathy through balance analysis: a promising tool
2019
[EN] The purpose of this study was to develop a tool able to distinguish between subjects who have haemophilic arthropathy in lower limbs and those who do not by analyzing the centre of pressure displacement. The second objective was to assess the possible different responses of haemophiliacs and healthy subjects by creating a classifier that could distinguish between both groups. Fiftyfour haemophilic patients (28 with and 26 without arthropathy) and 23 healthy subjects took part voluntarily in the study. A force plate was used to measure postural stability. A total of 276 centre of pressure displacement parameters were calculated under different conditions: unipedal/bipedal balance with e…
A ballistometer for the study of the plasto-elastic properties of skin.
1977
The ballistrometer is based on the "drop impact" of a body onto a stationary surface. A collision in one dimension is provoked by allowing a bard body to drop from a given height onto the skin surface to be tested. After the collision, the impacting body undergoes a variable number of rebounds decreasing in amplitude. By measuring the height of the rebounds, the amount of energy returned by the tissue is calculated in terms of coefficient of restitution e. The equipment, consisting of a hammer unit, a feeder-amplifier, and a plotter, is described. Ballistometry has been carried out on skin areas of 46 normal subjects ranging in age from 8 to 80 years, as well as on pathologic and cadaveric …
Endo-neuro-sonography: principles and 3-D technique
1997
To evaluate the usefulness of transendoscopic sonography we studied two new sono probes 6 F in diameter in 17 fresh specimens. We saw precise imaging of well-known anatomical structures and also gained an additional dimension in endoscopy, as the sono adds to the endo-view a transverse scan like a mini-CT at the tip of the probe. We also experienced the navigation characteristic of this imaging technique, both in real time and on line. Some 3-D reconstructions of the ventricular system were examined. The equipment has been used in clinical practice and must now be adapted for neurosurgery.